[CD7000] SMOChem™ dUTP Solution – Sodium Salt (100 mM), 25ml
Facebook
X
Pinterest
Email
Ultrapure dUTP (2´-Deoxyuridine, 5´-Triphosphate) supplied as sodium salt in purified water (pH 8.5). dUTP can be used in place of dTTP in PCR and RT-PCR protocols to prevent carryover from previous amplifications. The substitution of dUTP for dTTP in PCR results in uracil-containing PCR products that are suitable for most standard applications. The enzyme uracil-N-glycosylase (UNG, also referred to as UDG) can be added to a PCR premix to excise uracil from any contaminating PCR product, thereby preventing false positives. Each lot of dUTP is tested to ensure specific DNA amplification and the absence of nuclease activity.
Detail
Description
Ultrapure dUTP (2´-Deoxyuridine, 5´-Triphosphate) supplied as sodium salt in purified water (pH 8.5). dUTP can be used in place of dTTP in PCR and RT-PCR protocols to prevent carryover from previous amplifications. The substitution of dUTP for dTTP in PCR results in uracil-containing PCR products that are suitable for most standard applications. The enzyme uracil-N-glycosylase (UNG, also referred to as UDG) can be added to a PCR premix to excise uracil from any contaminating PCR product, thereby preventing false positives. Each lot of dUTP is tested to ensure specific DNA amplification and the absence of nuclease activity.
Features
Ideal for PCR amplification and cDNA synthesis
Nuclease and ribonuclease free
Applications
PCR
Avoid carryover contamination between PCRs to eliminate a source of false positives.
Attogene Universal Lateral Flow Assay Kits are a convenient ready-to-use kit for quick and cost-effective development of a lateral flow dipstick assay for detection of DNA and RNA products.
Formats (strep gold conjugate pad):
Detection of nucleic Acid (DNA or RNA) requires the use of a biotin and FAM-labelled primer during amplification. Test line: anti-FITC/FAM, Control Line: Biotin
Multiplex detection of nucleic Acid (DNA or RNA) requires the use of a biotin, FITC/FAM and Dig labelled primers during amplification.: Test Line #1: anti FITC/FAM, Line #2: anti-Dig, Line #3 Biotin.
Inquire about custom configurations: sales@attogene.com
Kit Components
50 -4.5mm Lateral Flow Dipsticks
10 mL Sample assay running buffer
Features & Benefits
Can be used for development of a lateral flow assay for detection of a variety of different molecules such as amplified DNA products from PCR, LAMP and RPA reactions.
No need to stripe capture antibodies
No expensive equipment required
Cost-effective way to screen for further downstream lateral flow assay development.
Document
50 Lateral Flow Dipsticks (4.5mm)
10 mL Sample assay running buffer
96 well plate
Controls
Blood samples contain rich DNA, including mitochondrial DNA, genomic DNA, circulating DNA (mostly released into blood after tumor cell apoptosis) in white blood cells, as well as parasitic viral or microbial DNA. These DNA are important parameters in clinical testing or diagnosis, which are also valuable materials for medical research. There are three main issues with extracting DNA from blood samples:
1. The sample is highly infectious, posing great harm to operators and the environment.
2. The source of DNA is complex and aportion of the nucleic acid, such as viral DNA or free DNA, may be lost during the operation, leading to downstream detection failure;
3. Blood sample contains a large amount of impurities and inhibitory factors.
Currently there are many methods available for extracting DNA from whole blood samples, such as phenol chloroform extraction, salting out method, etc. However, these methods require pre-treatment of blood sample, which removes red blood cells and isolate white blood cells in the first step. Due to the requirement that it cannot inactivate or kill pathogens during the process of removing red blood cells, the waste liquid (red blood cell lysate) and consumables may be contaminated by pathogens and become infectious, posing a danger to the entire laboratory environment and operators. In addition, during the process of removing red blood cells, useful nucleic acid information such as viruses, microorganisms, or circulating DNA is also lost, leading to experiment or detection failures.
The HiPure Blood DNA Kits series provided by Magen Company uses silica gel column purification technology, which can directly lyse whole blood samples without the need for white blood cell separation. Whole blood samples are directly mixed with lysates and proteases, resulting in the inactivation of pathogens, greatly reducing the infectivity, environmental pollution, and the chance of operators being infected. Due to the direct lysis and digestion of samples, except lymphocyte DNA, other circulating DNA as well as DNA from viruses and microorganisms, can also be recovered.
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA (e.g., genomic, viral, mitochondrial) can be purified from whole blood, tissue and culture cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from 10ml blood and 1g tissue using Maxi column
Applications
PCR, southern bolt and virus detection, etc
Purification method
Maxi spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot, semen and other clinical samples
Sample amount
3-10ml
Elution volume
≥700μl
Time per run
≤90 minutes
Liquid carrying volume per column
4ml
Binding yield of column
5mg
Principle
This product is based on silica column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Pertinence – specially designed for isolating DNA from 3-10ml blood and related body fluids
Wide applicability – handle a variety of liquid samples
Proteinase K, RNase A should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Blood samples contain rich DNA, including mitochondrial DNA, genomic DNA, circulating DNA (mostly released into blood after tumor cell apoptosis) in white blood cells, as well as parasitic viral or microbial DNA. These DNA are important parameters in clinical testing or diagnosis, which are also valuable materials for medical research. There are three main issues with extracting DNA from blood samples:
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
150 reactions