[NS1001] FluoroVue™ Nucleic Acid Gel Stain (10,000X), 500 μl x 5
Facebook
X
Pinterest
Email
FluoroVue™ Nucleic Acid Gel Stain (10,000X) is specially designed for in-gel use and is a safer replacement for conventional Ethidium bromide (EtBr), which poses a significant health and safety hazard to its users. It is a fluorescent stain which offers highly sensitive detection of double-stranded or single-stranded DNA and RNA in a convenient manner. FluoroVue™ Nucleic Acid Gel Stain offers high sensitivity that is several times greater than EtBr.
FluoroVue™ Nucleic Acid Gel Stain is compatible with both conventional UV gel-illumination systems as well as harmless long wavelength blue light illumination systems, like B-BOX™. When bound to nucleic acids, FluoroVue™ Nucleic Acid Gel Stain has a fluorescent excitation maximum of 250 and 482 nm, and an emission maximum of 509 nm. Therefore, it can replace EtBr without the need of changing existing lab imaging systems.
Detail
Description
FluoroVue™ Nucleic Acid Gel Stain (10,000X) is specially designed for in-gel use and is a safer replacement for conventional Ethidium bromide (EtBr), which poses a significant health and safety hazard to its users. It is a fluorescent stain which offers highly sensitive detection of double-stranded or single-stranded DNA and RNA in a convenient manner. FluoroVue™ Nucleic Acid Gel Stain offers high sensitivity that is several times greater than EtBr.
FluoroVue™ Nucleic Acid Gel Stain is compatible with both conventional UV gel-illumination systems as well as harmless long wavelength blue light illumination systems, like B-BOX™. When bound to nucleic acids, FluoroVue™ Nucleic Acid Gel Stain has a fluorescent excitation maximum of 250 and 482 nm, and an emission maximum of 509 nm. Therefore, it can replace EtBr without the need of changing existing lab imaging systems.
Features:
Excellent for in-gel staining
Sensitivity: 0.14 ng (DNA) or 1 ng (total RNA)
A safer alternative to EtBr
Compatibility: suitable to blue or UV light
Increased cloning efficiency (blue light)
Storage
Protected from light 4°C for 12 months -20°C for 24 months
Other Products
R4310 HiPure Universal miRNA Kit
Product Info
Document
Product Info
Introduction
The Kit is designed for purification of total RNA, including miRNA and other small RNA molecules (18nt), from cultured cells and various animal and human tissues, including difficult-to-lyse tissues samples. Alternatively, a miRNA-enriched fraction and a total RNA (>200nt) fraction can be purified separately. This Kit combines phenol/guanidine-based lysis of samples and silica membrane–based purification of total RNA. MagZol Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate, designed to facilitate lysis of tissues, to inhibit RNases, and also to remove most of the cellular DNA and proteins from the lysate by organic extraction.
Details
Specifications
Features
Specifications
Main Functions
Isolation miRNA and other small RNA molecules(18nt), from cultured cells and various animal and human tissues, using MagZol reagent and column
Applications
RT-PCR, Northern Blot, poly A+purification, nucleic acid protection and in vitro translation
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such asguanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein andother impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
This kit combines acid/guanidine (MagZol) extraction technology with glass fiber filter membrane purification, which can improve the extraction effect of complex samples and samples with low RNA content. After the sample is treated with MagZol reagent and chloroform, the supernatant is added with ethanol to provide appropriate binding conditions, then transferred to the purification column and centrifuged. Macromolecular RNA can be efficiently bound to the membrane. Collect the filtrate containing small RNA, add more ethanol to adjust the binding capacity of small RNA, the pollutants can be efficiently washed away by second cleaning. Finally, the purified RNA was eluted by RNase free water.
Advantages
High quality – one step RNA extraction reagent combined with silica gel column can obtain the highest concentration
Fast – several samples can be extracted in 40 minutes
High applicability – samples including animals, plants, bacteria, cells, etc.
High concentration – efficiently remove macromolecular RNA, enrich small RNA and improve sensitivity
Kit Contents
Contents
R431002
R431003
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
100
2 x 250
2ml Collection Tubes
100
2 x 250
MagZol Reagent
60 ml
270 ml
Buffer RWC
20 ml
80 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
MagZol Reagent should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect its performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
The Kit is designed for purification of total RNA, including miRNA and other small RNA molecules (18nt), from cultured cells and various animal and human tissues, including difficult-to-lyse tissues samples. Alternatively, a miRNA-enriched fraction and a total RNA (>200nt) fraction can be purified separately. This Kit combines phenol/guanidine-based lysis of samples and silica membrane–based purification of total RNA. MagZol Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate, designed to facilitate lysis of tissues, to inhibit RNases, and also to remove most of the cellular DNA and proteins from the lysate by organic extraction.
AAV Purification from any input – cell fraction or media fraction
High AAV recovery, up to 90%
No specialized equipment needed
Purification from a variety of AAV serotypes (including AAV6 and AAV9)
Yields highly active AAV for in vivo and in vitro experiments
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
Recombinant adeno-associated virus (AAV) vectors are highly promising tools for both in vitro and in vivo gene transfer. Norgen’s AAV Purification Kits provide fast and simple procedures for concentrating and purifying AAV vectors from cell lysate and cell culture media. Purification is based on precipitation onto Norgen Biotek’s proprietary resin. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. AAV vector purified in this manner is highly active for use in in vitro and in vivo transduction experiments.
AAV Purification Kit
Norgen’s AAV Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant (SN) or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit. Up to 33X sample concentration.
AAV Purification Mini Kit
Each spin column is able to concentrate and purify AAV from 0.5-8 mL of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (200 µL). Preparation time for 4 samples is 1.5 hours, with 45 minutes of hands-on time.
AAV Purification Midi Kit
Each spin column is able to concentrate and purify AAV from 8 mL up to 45 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1 mL). The kit may be used to purify up to 8 x 25 mL or 4 x 45 mL of samples using the included columns. Preparation time for 4 samples is approximately 2 to 2.5 hours, with 1.5 hours of hands on time.
AAV Purification Maxi Kit (Slurry Format)
Each spin column is able to concentrate and purify AAV from 45 mL to 90 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 200X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1-10 mL) using the optional concentration step. The kit may be used to purify up to 1 x 900 mL samples or 10 x 45-90 mL samples using the included columns. Preparation time for 1 x 900 mL sample is approximately 2.5 to 3.5 hours, with an optional concentration step requiring an additional 30 min.
At least 5 x 109 AAV particles as determined by qPCR
AAV Vector Serotype
Any
Average Recovery
> 80%
Input Type
Cells, media, or mixed
Input Volume
0.5 mL – 8 mL
Minimum Elution Volume
200 µL
Time to Complete Purifications
1 – 2 hours
Storage Conditions and Product Stability DNAse I and RNAse A should be stored at -20°C upon arrival. Elution Buffer O should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. Once opened, the solutions should be stored at 4°C. This kit is stable for 1 year after the date of shipment.
Component
Cat. 66100 (15 preps)
Cat. 63200 (20 preps)
Cat. 63300 (4-8 preps)
Cat. 63250 (1-10 preps)
Lysis Buffer S
5.5 mL
5.5 mL
5.5 mL
20 mL
DNAse I
–
2 x 25 uL
2 x 25 uL
210 μL
RNAse A
–
60 μL
60 μL
240 μL
HL-SAN Nuclease
102 μL
–
–
–
Binding Buffer A
20 mL
4 mL
4 mL
2 x 8 mL
Purification Solution C
60 mL
–
–
–
Purification Solution D
130 mL
–
–
–
Wash Solution C
2 x 130 mL
60 mL
60 mL
3 x 60 mL
Slurry E
12.5 mL
–
–
2 x 14.5 mL
Elution Buffer O
66 mL
8.5 mL
8.5 mL
66 mL
Protein Neutralizer
4 mL
4 mL
4 mL
4 mL
Spin Columns
–
20
–
–
Mini Spin Columns
–
20
–
–
Midi Spin Columns (grey contents) with Collection Tubes
–
–
8
10
Midi Spin Columns (white contents) with Collection Tubes
–
–
8
–
Maxi Spin Columns (grey contents) with Collection Tubes
–
–
–
10
Maxi Spin Columns (white contents) with Collection Tubes
Norgen’s Saliva Exosome Collection and Preservation Kit is an all-in-one solution designed for 1) simple and non-invasive saliva collection; 2) preservation of exosomes in saliva samples at ambient temperature; and 3) isolation of high quality intact exosomes and exosomal RNA within a laboratory setting. The Saliva Exosome Collection, Preservation and Isolation Kit contains 50 Individual Saliva Exosome Collection and Preservation Devices. Each of the 50 individual Saliva Exosome Collection and Preservation Devices consists of 3 components:
Saliva Collection Funnel and Collection Tube that contains Norgen’s Preservative in a dried format
Collection Tube Cap
ID Label
Saliva samples are collected by spitting inside the Collection Funnel which has been assembled with the Collection Tube. After collecting the required volume of saliva the Collection Funnel is removed, the Collection Tube is securely capped with Collection Tube Cap. The collected saliva is mixed by gentle inversion for several times till the saliva colour changes into yellow. The Saliva Collection Tube is subsequently sent to the laboratory for the purification of intact exosomes and for the subsequent isolation and analysis of saliva exosomal RNA. The saliva exosomes in preserved samples are stable for 2 years at room temperature.
Details
Kit Specifications
Volume of Saliva Collected
2 mL
Preservation Temperature
Room Temperature
Preservation time
2 years at room temperature
Shelf Life and Handling
The Collection Device should be kept tightly sealed and stored at room temperature for up to 2 years without any reduction in kit performance (The collection due date is written on the device label).
The Collection Tube, the Collection Funnel and the Device Container of each Individual Saliva DNA Collection and Preservation Device are recyclable.
Kit Components
Cat. 65400 (50 Devices)
Individual Saliva Exosome Collection and Preservation Devices
50
Donor Procedure Flowchart
1
Product Insert
1
Individual Saliva Exosome Collection and Preservation Device Contents