Heat sealing film for 96- and 384-well PCR microplates.
Detail
Heat sealing film for 96- and 384-well PCR microplates.
About
We are thrilled to announce the latest addition to our consumables range at 3CR Bioscience: heat sealing film for 96- and 384-well PCR plates.
This rigorously tested, permanent seal film complements our rigid frame 384-well PCR plates perfectly. Its superior clarity allows for easy sample visualisation and monitoring, ensuring excellent data quality.
Crafted from high-quality materials, the seal offers excellent chemical resistance and plate compatibility. Designed with durability, the film provides a secure seal with precise fit and strong adhesion, safeguarding sample integrity throughout amplification, re-cycling, and reading.
Both seals and our 384-well plates are ideal for automated, high-throughput PCR environments, including robotic handling. The film remains stable during thermal cycling in PCR machines and hydro cyclers, offering performance and convenience across various PCR workflows.
With this new addition, we reaffirm our commitment to delivering reliable, high-performance, and affordable products that empower scientists worldwide.
Contact us today to include a free sample of plate and seal in your next shipment!
Other Products
Cerillo Stratus Plate Reader (600nm)
Product Info
Document
Product Info
Cerillo’s Stratus Plate Reader is a third party module that can be placed next to or inside the OT-2 or Opentrons Flex for post experimental analysis. The worktable adapter will allow you to utuilize the OT-2 or Opentrons Flex to prepare the samples directly into the plate reader positions on the worktable.
This small portable device is primarily for microbial growth curve analysis. The Stratus is compatible with Cerillo’s Canopy wireless device that allows real time visualization, control, and analytics. This product is compatible with reading 600nm wavelengths.
Document
Cerillo’s Stratus Plate Reader is a third party module that can be placed next to or inside the OT-2 or Opentrons Flex for post experimental analysis. The worktable adapter will allow you to utuilize the OT-2 or Opentrons Flex to prepare the samples directly into the plate reader positions on the worktable.
This small portable device is primarily for microbial growth curve analysis. The Stratus is compatible with Cerillo’s Canopy wireless device that allows real time visualization, control, and analytics. This product is compatible with reading 600nm wavelengths.
Sequentially purify total RNA and total proteins from a single sample
Kit includes a gDNA elimination column
No sample splitting required
No phenol step required for efficient isolation
Ideal for small or difficult to obtain samples
Purify RNA and proteins from cultured animal cells, tissues, blood, bacteria, yeast, fungi or plants
Rapid and efficient spin column procedure
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
This kit provides a rapid, single column method for the isolation and purification of total RNA (including miRNA) and proteins sequentially from a single sample of cultured animal cells, tissues, blood, bacteria, yeast, fungi or plants. The total RNA and proteins are both column purified in under 25 minutes using a single column.
Purified RNA is of a high quality and yield, and is suitable for NGS, RT-qPCR and microarrays.
This kit eliminates DNA efficiently using a gDNA removal column.
Proteins are eluted in buffer and are ready for downstream applications such as Western Blots, Mass Spec and ELISA. The proteins will not require precipitation, resuspending of pellets, or any further cleaning.
This kit is ideal for researchers who are interested in studying the transcriptome and proteome of a single sample, such as for studies of microRNA profiling, gene expression including gene silencing experiments or mRNA knockdowns, studies involving biomarker discovery, and for characterization of cultured cell lines. Norgen’s RNA/Protein Purification Plus Kit is especially useful for researchers who are isolating macromolecules from precious, difficult to obtain or small samples such as biopsy materials or single foci from cell cultures, as it eliminates the need to fractionate the sample. Furthermore, analysis will be more reliable since the RNA and proteins are derived from the same sample, thereby eliminating inconsistent results. The purified macromolecules are of the highest purity and can be used in a number of different downstream applications.
Average Yields*: HEK 293 Cells (1 x 106 cells) HEK 293 Cells (1 x 106 cells) Liver (15 mg) Liver (15 mg)
10-15 μg RNA 70-100 μg protein 30-35 μg RNA 100-150 μg protein
* Average yields will vary depending upon a number of factors including species, growth conditions used and developmental stage.
Storage Conditions and Product Stability The Protein Loading Dye should be stored at -20°C after the addition of DL-Dithiothreitol (DTT). All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
The Opentrons Temperature Module, compatible with both the OT-2 and Flex Robots, is a fully automated thermoelectric module and integrated for use with the Opentrons platform. It is used to achieve temperature changes ranging from 4 to 95°C for various applications.
The Temperature Module GEN2 is compatible with the new Opentrons Flex Robot when paired with the Flex Temperature Caddy and Calibration Adapter. The caddy sits below the deck to enable below-deck cable routing and labware placed on modules remain closer to the deck surface. The calibration adapter is used to calibrate the location of the module. If you choose to include the Opentrons Flex Caddy and Calibration Adapter, your order will ship in 20 business days.
Document
The Opentrons Temperature Module, compatible with both the OT-2 and Flex Robots, is a fully automated thermoelectric module and integrated for use with the Opentrons platform. It is used to achieve temperature changes ranging from 4 to 95°C for various applications.
The Temperature Module GEN2 is compatible with the new Opentrons Flex Robot when paired with the Flex Temperature Caddy and Calibration Adapter. The caddy sits below the deck to enable below-deck cable routing and labware placed on modules remain closer to the deck surface. The calibration adapter is used to calibrate the location of the module. If you choose to include the Opentrons Flex Caddy and Calibration Adapter, your order will ship in 20 business days.