The Permagen 96-well 0.2 mL PCR Strip Rack was designed for use in manual or automation applications where strip tubes are required. It can also be used with
Detail
The Permagen 96-well 0.2 mL PCR Strip Rack was designed for use in manual or automation applications where strip tubes are required. It can also be used with our MSP750 MSP750RMSPU650R or MSPU650 magnet plates and is available as a discounted kit Picture shown is SKU: MSPU650RKT for reference
TGL20 Table Top High Speed Refrigerated Centrifuge
Product Info
Document
Product Info
TGL20 Technical Parameters
Max Speed
21000r/min
Max Volume
6×100ml
Timer
1~99h59min
Dimension
570×620×380mm
Speed Accuracy
±20r/min
Max RCF
30910×g
Noise
≤58dBA
Net Weight
84KG
Power supply
AC 220V, 50HZ 10A
Temperature Range
-20℃~40℃
Temperature Accuracy
±1℃
Matched Rotors for TGL20
Order no
Rotor
Max Speed(r/min)
Volume(ml)
Max RCF(*g)
G20-1
Fixed Rotor
16000
4×8PCR
15760
G20-2
Fixed Rotor
15000
6×8PCR
21420
G20-3
Fixed Rotor
16000
8×8PCR
17480
G20-4
Fixed Rotor
15000
12×8PCR
22930
G20-5
Fixed Rotor
21000
12×1.5/2ml
30910
G20-6
Fixed Rotor
15000
40×0.5ml
22920
G20-7
Fixed Rotor
17000
24×1.5/2ml
26460
G20-8
Fixed Rotor
13500
30×1.5/2ml
19340
G20-9
Fixed Rotor
13000
48×1.5/2ml
17930
G20-10
Fixed Rotor
16000
16×5ml
22020
G20-11
Fixed Rotor
16000
6×10ml
21500
G20-12
Fixed Rotor
15000
12×10ml
22680
G20-13
Fixed Rotor
16000
12×7ml
21380
G20-14
Fixed Rotor
13000
16×10ml
19490
G20-15
Fixed Rotor
10000
12×15ml
11840
G20-16
Fixed Rotor
13000
8×15ml(falcon)
17790
G20-17
Fixed Rotor
5000
24×15ml
3500
G20-18
Fixed Rotor
15000
8×20ml
22680
G20-19
Fixed Rotor
5000
30×15ml
3830
G20-20
Fixed Rotor
14000
6×30ml
19060
G20-21
Fixed Rotor
13000
6×50ml(falcon)
18840
G20-22
Fixed Rotor
13000
6×50ml(round)
18730
G20-23
Fixed Rotor
13000
4×85ml
18940
G20-24
Fixed Rotor
12000
6×70ml
15570
G20-25
Fixed Rotor
12000
4×100ml
14850
G20-26
Fixed Rotor
12000
6×100ml
16390
G20-27
Fixed Rotor
12000
24 pieces capillary vessel
15800
G20-28
Fixed Rotor
18000
30×0.5ml
26660
G20-29
Swing Rotor
13000
4×5ml
14960
G20-30
Vertical Rotor
16000
16×5ml
16540
G20-31
Vertical Rotor
14000
8×30ml
16450
G20-32
Microplate Rotor
4000
2×3×48(well)
2300
Document
Features: 1. Digital display indicates the speed,time,temperature and RCF. 2. Brushless DC motor in great torque, free maintenance,no powder pollution.quick in speed up and down. 3. There are many kinds of rotors for choice. 4. Automatically electric lid lock,super speed,over temperature protection and imbalance protection. 5. The centrifuge body is made of high-quality steel,safe and reliable.
As this is a 2 gene kit, we recommend purchase of 2 of the accompanying RT-qPCR master mix reagent: oasig Lyophilised OneStep RT-qPCR Master Mix 150 reactions.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Primer and probe mix (150 reactions) Reverse Transcription, target specific primers (RNA genome viruses only) Copy number standard curve (sufficient for multiple standard curves) Internal extraction control – Read through VIC channel* Endogenous control (150 tests) RNAse/DNAse free water *alternative fluorophores available on request
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
The kit is based on room and constant temperature nucleic acid rapid amplification technology, its principle is that at room and constant temperature, the recombinase and primer form a protein/single-stranded nucleotide complex Rec/ssDNA, and invade the double-stranded DNA template with the help of auxiliary proteins and single-stranded binding protein SSB; then form a D-loop region at the invasion point and start to scan the DNA duplex, after finding the target region complementary to the primer and disintegration of the complex Rec/ssDNA, the polymerase also binds to the 3′ end of the primer to start the chain extension. The kit relies on the role of NFO enzyme and adds the designed specific molecular probes according to the template, and get the result by colloidal gold technology (sandwich method).
Technical Parameters:
Parameters
Details
Product Name
DNA Isothermal Amplification Kit NFO
Manufacturer
Amp-future
Storage Temperature
-20°C
Kit Components
Enzymes, Buffers ,Reagents
Packaging
48 Tests/box
Detection Limit
500-1000copies/µL
Shipping
ICE
Test Time
5-20mins
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
3/ The reaction can be operated by metal bath and water bath pot without purchasing expensive PCR apparatus.
Isothermal nucleic acid Applications
Suitable for DNA isothermal rapid amplification kit(NFO type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
DNA basic kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.