96-Well Low Elution PCR side pull bar magnetic plate with integrated cushion base
Facebook
X
Pinterest
Email
Permagen’s new low elution bar magnet plate for PCR applications features an individual bar magnet for each row of wells making it the perfect solution for hand pipetting. With its SBS footprint and integrated cushion base, scaling up to the robot is a snap. Available in kit form as well, which includes our X39602 top plate for 0.2 mL tubes & strips
Detail
Permagen’s new low elution bar magnet plate for PCR applications features an individual bar magnet for each row of wells making it the perfect solution for hand pipetting. With its SBS footprint and integrated cushion base, scaling up to the robot is a snap. Available in kit form as well, which includes our X39602 top plate for 0.2 mL tubes & strips
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
Plasma/Serum Circulating and Exosomal RNA Purification Kits (Slurry Format)
Product Info
Document
Product Info
Overview
Isolate all sizes of circulating and exosomal RNA, including microRNA
Versatile plasma and serum input volumes
Concentrate circulating and exosomal RNA into small elution volumes
Isolate inhibitor-free circulating and exosomal RNA
Bind and elute all RNA irrespective of size or GC content, without bias
Available in Spin Column or 96-well plate formats
Process 96-well plates using vacuum or centrifugation
Purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Compatible with Streck Cell-Free RNA BCT® Tubes
Purification is based on Norgen’s proprietary resin matrix
These kits are able to isolate all sizes of circulating and exosomal RNA, including microRNA, without the use of phenol or chloroform. The slurry format provides an advantage over other available kits in that it does not require extension tubes for the purification of free-circulating and exosomal RNA from large sample volumes. RNA can be isolated from either fresh or frozen samples using this kit. This kit is suitable for the isolation of RNA from serum or plasma prepared from blood collected only on either EDTA or citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications including RT-PCR. The purified plasma/serum free-circulating and exosomal RNA is eluted in an elution solution that is compatible with PCR, qPCR, methylation-sensitive reverse transcription qPCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, expression array assays, and NGS.
Free-circulating plasma and serum RNA can serve as both tumor- and fetal-specific markers for cancer detection and prenatal diagnosis. As well, free-circulating RNAs have the potential to provide biomarkers for other disease states. Free-circulating RNA in plasma or serum are usually present as short fragments of less than 1000nt, and free-circulating miRNA (21nt) can also be found in plasma and serum.
Plasma/Serum Circulating and Exosomal RNA Purification Kit (Slurry)
Norgen’s Plasma/Serum Circulating and Exosomal RNA Purification Kit (Slurry Format) provides a fast, reliable and simple procedure for isolating circulating RNA and exosomal RNA from plasma and serum samples ranging from 0.25 mL to 5 mL.
Plasma/Serum Circulating and Exosomal RNA Purification Mini Kit (Mini Slurry)
Norgen’s Plasma/Serum Circulating and Exosomal RNA Purification Mini Kit (Slurry Format) provides a fast, reliable and simple procedure for isolating circulating and exosomal RNA from plasma and serum samples ranging from 0.25 mL to 2 mL.
Norgen’s Plasma/Serum Circulating and Exosomal RNA Purification 96-Well Kit (Slurry Format) provides a high throughput method for isolating circulating and exosomal RNA from plasma and serum samples using either a vacuum manifold or centrifugation.
Plasma/Serum Circulating and Exosomal RNA Purification Maxi Kit (Maxi Slurry)
Norgen’s Plasma/Serum Circulating and Exosomal RNA Purification Maxi Kit (Slurry Format) provides a fast, reliable and simple procedure for isolating circulating RNA and exosomal RNA from various amounts of plasma/serum ranging from 2 mL to 5 mL.
Cat.29500 Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Free-circulating nucleic acids, such as tumor-specific extracellular DNA fragments and mRNAs in the blood or fetal nucleic acids in maternal blood, are present in serum or plasma usually as short fragments, <1000bp (DNA). HiPure Circulating DNA Midi Kit enables efficient purification of these circulating nucleic acids from human plasma, serum, or urine. The extracted products can be used for clinical in vitro detection.
Details
Specifications
Features
Specifications
Main Functions
Isolation circulating DNA from 1-5ml plasma, serum, body fluids using vacuum protocol
Applications
qPCR, liquid or solid chip analysis, hybridization and SNP detection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (vacuum)
Sample type
Serum, plasma and other cell-free fluid samples
Sample amount
1-5ml
Elution volume
≥50μl
Time per run
≤60 minutes
Liquid carrying volume per column
4ml
Binding yield of column
1mg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer.
Advantages
High yield – most optimal process, free DNA (>50bp) can be obtained to the maximum extent
High concentration – low elution volume, ensuring high nucleic acid concentration
High purity – low alcohol binding method, completely removing inhibitor and protein pollution
High recovery – DNA can be recovered at thelevel of PG by silica gel column purification
Kit Contents
Contents
IVD3182
Purification Times
50
Buffer ACL
250 ml
Buffer ACB*
300 ml
Buffer DCW1*
22 ml
Buffer DCW2*
10 ml
Proteinase K
540 mg
Protease Dissolve Buffer
30 ml
Carrier RNA
110 μg
Nuclease Free Water
20 ml
HiPure CFDNA Mini Columns
50
2 ml Collection Tubes
100
Extender Tube
50
Vac-Connector
50
Storage and Stability
Proteinase K, Carrier RNA should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
Free-circulating nucleic acids, such as tumor-specific extracellular DNA fragments and mRNAs in the blood or fetal nucleic acids in maternal blood, are present in serum or plasma usually as short fragments,
The 16S V2-V3 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V2-V3 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.
The 16S V2-V3 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V2-V3 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.
Storage Conditions and Product Stability Norgen’s 16S V2-V3 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components should remain stable for at least 1 year when stored at the specified storage conditions.