The Heat&Run® gDNA removal kit removes contaminating gDNA from RNA prior to RT-qPCR.
The kit is based on the recombinant heat labile dsDNase, which is irreversibly inactivated at low temperatures (5 minutes at 58ºC or 15 minutes at 55ºC).
Reverse Transcription can be performed in the same tube, thereby minimizing pipetting steps and reducing hands-on time.
Detail
OverView
The Heat&Run® gDNA removal kit removes contaminating gDNA from RNA prior to RT-qPCR.
The kit is based on the recombinant heat labile dsDNase, which is irreversibly inactivated at low temperatures (5 minutes at 58ºC or 15 minutes at 55ºC).
Reverse Transcription can be performed in the same tube, thereby minimizing pipetting steps and reducing hands-on time.
Protocol
The kit contains HL-dsDNase which efficiently removes gDNA from RNA preps before running RT-qPCR.
gDNA is removed, leaving RNA ready for reverse transcription in the same tube (Figure 1).
Heat-labile dsDNase can easily be inactivated.
This procedure minimizes pipetting steps and reduces hands-on time.
The Heat&Run kit is especially well suited for high throughput experiments.
The high activity of the HL-dsDNase at low temperature and its heat-lability makes it ideal to use in a combination with a heat activated RT enzyme. The contaminating genomic DNA is cleaved at ambient temperature and increasing the temperature over 50°C will inactivate the DNase and start the Reverse Transcriptase.
Do you require gDNA removal in applications other than RT-qPCR? Contact our support team for assistance in implementing dsDNase treatment in your workflow.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 6 months under recommended storage conditions
Analyte:
Acetaldehyde
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
0.5 to 20 µg of acetaldehyde per assay
Limit of Detection:
0.18 mg/L
Reaction Time (min):
~ 4 min
Application examples:
Wine, champagne, beer, liqueurs, brandy, dairy products (e.g. yogurt), bread, fruit juices, soft drinks, cocoa, vegetable and fruit products, coffee, and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by MEBAK
The Acetaldehyde test kit is a simple, reliable and accurate method for the measurement and analysis of acetaldehyde in beverages and foodstuffs.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Apply to drying in laboratories such as cosmetics, fermentation broth, soil, materials, etc.
product description:
9kg-12kgs water capture capacity, which can meet the needs of laboratories with large freeze-drying requirements for water capture capacity
-70°C/-90°C ultra-low temperature cold trap, which can capture lower temperature organic solvents
Unique refrigeration technology, the cooling time of the cold trap from the start of the low-temperature refrigeration system to the target value is ≤3 minutes
Hemispherical cold trap bottom surface is more conducive to the discharge of condensed water
The cold trap and condenser coil are all Teflon anti-corrosion treatment, which can freeze-dry a large amount of ultra-low temperature organic solvents
One-click hot gas defrost, with defrost compressor protection program.
Large flat flange silicone seal, permanently no need to apply any auxiliary sealing silicone grease
High-precision ultra-wide width detection, vacuum sensor with full-range automatic temperature compensation, making vacuum display more accurate
The cavity vacuum can be read and controlled accurately, and the vacuum control accuracy is ≤0.1mbar
Removable sample shelf with dedicated holes for centrifuge tube placement, making placement and height adjustment easier
Configuration of various types of chambers and T-frames can fully satisfy users’ sample placement
Optional configuration of eutectic point detection system and data export system.
The vacuum pump and sample placement chamber can be combined at will according to user needs, making the configuration more flexible and convenient
Techinical parameter
9-12L Floor tabletop and floor standing one for lab usage
Tabletop
BD1-9
BD2-9
BD1-12
BD2-12
Floor standing
BH1-9
BH2-9
BH1-12
BH2-12
Water Capture capacity
9L
12L
Cold trap temperature
-70 C
-90℃
-70C°
-90℃
Cold trap volume
15L
20L
Freeze dried chamber
High permeability organic glass/multi manifold external valve/stainless steel chamber
PACE OneStep RT-PCR Master Mix combines reverse transcription (RT) and PCR in a single reaction. This advanced master mix simplifies workflows by eliminating the need for separate reactions for reverse transcription of RNA to cDNA, and PCR amplification from the newly generated cDNA. PACE OneStep RT-PCR Master Mix is highly efficient and sensitive, enabling detection of low-abundance RNA targets, particularly useful for applications such as gene expression analysis and viral RNA detection. PACE OneStep RT-PCR Master Mix demonstrates robust performance across a wide range of RNA templates and can be employed for both routine and challenging samples.