The Ethanol (Liquid Ready) assay kit is a rapid (~5 min), method for the specific measurement and analysis of ethanol in wine, beverages, foodstuffs and other materials. Supplied as a “ready to use” liquid stable formulation that is suitable for manual auto-analyser and microplate formats and is simple, reliable and accurate.
Suitable for manual, auto-analyser and microplate formats.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
All reagents stable for > 12 months after preparation
Rapid reaction (~ 7 min)
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Other Products
TwistAmp® exo
Product Info
Document
Product Info
Real-time fluorescent DNA amplification made possible with a TwistAmp® exo kit. Recommended for users who want to combine TwistDx’s RPA amplification technology with the use of TwistDx’s proprietary fluorescent TwistAmp® exo probe in a homogenous format. The user need only supply primers, probe, and template. See manual for more information. Click to order oligonucleotides.
Document
Real-time fluorescent DNA amplification made possible with a TwistAmp® exo kit. Recommended for users who want to combine TwistDx’s RPA amplification technology with the use of TwistDx’s proprietary fluorescent TwistAmp® exo probe in a homogenous format. The user need only supply primers, probe, and template. See manual for more information. Click to order oligonucleotides.
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection. HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.
Details
Specifications
Features
Specifications
Main Functions
Isolation both Circulating DNA/RNA (include miRNA) from 1-5 ml serum and plasma
Applications
qPCR / RT-PCR, liquid or solid-phasechip analysis, hybridization and SNP detection
Purification method
Midi spin column
Purification technology
Silica technology, DNA filtration technology
Process method
Manual (centrifugation or vacuum)
Sample type
serum, plasma, and other cell-free liquid samples
Sample amount
1-5 ml
Elution volume
≥20μl
Time per run
≤100 minutes
Liquid carrying volume per column
4 ml
Binding yield of column
1 mg
Principle
This kit is based on silica gel column technology. Serum or other liquid samples are lysed and digested in buffer CFL. After adding buffer CFP, the protein is removed by centrifugation to obtain the supernatant. Isopropanol is added to precipitate the total nucleic acid and transferred to the column for filtration. DNA / RNA is adsorbed on the membrane of the column, while the protein is not adsorbed and removed with the filtrate.The column is washed with buffer MGW1 to remove protein and other impurities, and then washed with buffer RW2 to remove salt. Finally, DNA / RNA is eluted by low salt buffer. The eluted DNA / RNA can be directly used for quantitative PCR/ RT-PCR, liquid or solid-phase chip analysis, hybridization and SNP detection.
Advantages
High yield – most optimized process to obtain maximum free RNA and small RNA
High concentration – low elution volume (>20μl) to ensure nucleic acid concentration
High purity – low alcohol combination, completely remove inhibitor and protein pollution
High recovery – silica gel column technology can recover nucleic acid molecules at the level of PG
Large volume – 1-2ml serum and plasma samples can be processed at one time
Kit Contents
Contents
R431602
D431603
Purification Times
50 Preps
250 Preps
HiPure RNA Micro Columns
50
5 x 50
HiPure Viral Midi Columns
50
5 x 50
15 ml Collection Tubes
50
5 x 50
2ml Collection Tubes
50
5 x 50
Buffer CFL
150 ml
2 x 375 ml
Buffer CFP
30 ml
150 ml
Buffer MGW1*
100 ml
2 x 250 ml
Buffer RW2*
2 x 50 ml
5 x 100 ml
RNase Free Water
10 ml
50 ml
Storage and Stability
The kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection.
HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.