Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 1 year under recommended storage conditions
Analyte:
L-Glutamic Acid, MSG
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
492
Signal Response:
Increase
Linear Range:
0.4 to 20 µg of L-glutamic acid per assay
Limit of Detection:
0.21 mg/L
Reaction Time (min):
~ 8 min
Application examples:
Fruit and vegetables (e.g. tomato), processed fruit and vegetables (e.g. tomato puree / juice, ketchup, soy sauce), condiments, processed meat products (e.g. extracts, bouillon and sausages), soup, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by ISO, GOST and NMKL
The L-Glutamic Acid test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of L-glutamate (MSG) in foodstuffs.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
No wasted diaphorase solution (stable suspension supplied)
Rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Other Products
Urine Exosome Purification Kit
Product Info
Document
Product Info
Overview
Purification and enrichment of intact exosomes from plasma, serum, urine, cell culture media and saliva in less than 30 minutes.
Versatile sample input ranging from 250 µL to 30 mL
Urine Exosome Purification Mini Kit (250 µL – 1 mL urine)
Urine Exosome Purification Midi Kit (2 mL – 10 mL urine)
Urine Exosome Purification Maxi Kit (11 mL – 30 mL urine)
Exosome purification is based on Norgen’s proprietary resin separating matrix through exosomes’ surface proteins.
No precipitation reagents, overnight incubation, protease or coagulant treatments required
No time-consuming ultracentrifugation, filtration or special syringes required
Purify intact exosomes with a size ranging from 40-200 nm depending on sample input type
Purified exosomes are compatible with functional studies.
Purified exosomes are free from any protein-bound cell-free circulating RNA
Purified exosomes are compatible with NanoSight® or Electron Microscopy for assessing the approximate exosome size range and concentration.
Exosomal RNA can be extracted from the purified exosomes using Norgen’s Exosomal RNA Purification technology or any other RNA extraction method.
The Urine Exosome Purification Kits provide a fast, reliable and convenient method to purify and enrich for pure intact exosomes from different urine sample volumes ranging from 250 µL to 30 mL. These kits also allow for the purification of intact extracellular vesicles (EVs) from different urine sample volumes, and these EVs are ready for any downstream application. The purification is based on Norgen’s proprietary resin.
These kits provide a clear advantage over other available methods since they do not require any special instrumentation, ultracentrifugation, precipitation reagents or any protease treatments. More importantly, the purified exosomes will not be contaminated with any other RNA-binding proteins that may contaminate your exosomal RNA, which is essential if studying exosomal RNA gene expression.
NanoSight® Analysis
Exosomes enriched with Norgen’s Urine Exosome Purification Kits can be analyzed using NanoSight® for assessing the approximate exosome size range and concentration.
Exosomal RNA Analysis
Exosomal RNA can be isolated using Norgen’s Exosomal RNA Isolation Kit from exosomes enriched using Norgen’s Urine Exosome Purification Kits for gene expression analysis using RT-qPCR, microarray or NGS and for Biomarker discovery.
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature. These kits are stable for 2 years after the date of shipment.
Important Note Urine samples stored at -70°C, -20°C or at 4°C will develop some precipitation due to the aggregation of some of the highly abundant proteins in urine. Eliminating these precipitates using centrifugation or filtration may cause the loss of exosomes. Furthermore, these precipitates may affect the quality of the purified nucleic acid. We recommend the use of Norgen’s Urine Preservative when collecting urine samples, which is designed for the preservation of nucleic acids and proteins in fresh urine samples at ambient temperatures. The components of the Urine Preservative allow samples to be stored for over 2 years at room temperature with no detected degradation of urine DNA, RNA or proteins. Norgen’s Urine Preservative is available as a liquid format in Norgen’s Urine Preservative Single Dose Ampules, as well as in a dried format in Norgen’s Urine Collection and Preservation Tubes.
Bis-propargyl-PEG12 has two alkyne groups at both ends of the linker. With the catalyzation of copper, the alkyne groups reacts with azide compounds to form stable triazole linkages. The PEG spacer enhances the water-solubility of the compound. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
Bis-propargyl-PEG12 has two alkyne groups at both ends of the linker. With the catalyzation of copper, the alkyne groups reacts with azide compounds to form stable triazole linkages. The PEG spacer enhances the water-solubility of the compound. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Cell Culture Flask surface is very smooth based on precise molding technology and it gives clear view when examined with microscope.
Volume: 25mL75mL175mL225mL
PRODUCT FEATURES
The product is made of medical grade USP CLASS VI polymer polystyrene
The product is made under a 100,00- class dust-free manufacturing site
Two kinds of product line up are providing.
For adherent cell culture: Initial adherence and proliferative property of cells via hydrophilic surface treatment.
For suspension cell culture: The surface is resistant to cell adherence, which minimizes damage or loss of cell.
Large mouthed design makes easy operation of pipet or cell scraper. The surface of flask is uniform and smooth, hence the clear view can be obtained when microscopic observation.
The hydrophobic filter cap can prevent invasion of fungi and bacteria without water absorb.
Gamma radiation sterilization
Non-Pyrogenic, DNase/Rnase free.
Document
Cell Culture Flask surface is very smooth based on precise molding technology and it gives clear view when examined with microscope.