Grey, low profile PCR plate with a rigid two-component hardshell design which eliminates warping and distortion during PCR testing.
Grey
Polycarbonate frame
Low-profile PCR plate
Rigid two-component design eliminates warping and distortion during PCR
96W Clear Thin Walled PP Tubes
Full Skirt
Packaged 10 plates per sleeve, 50 plates per box
Detail
Overview
Grey, low profile PCR plate with a rigid two-component hardshell design which eliminates warping and distortion during PCR testing.
Grey
Polycarbonate frame
Low-profile PCR plate
Rigid two-component design eliminates warping and distortion during PCR
96W Clear Thin Walled PP Tubes
Full Skirt
Packaged 10 plates per sleeve, 50 plates per box
Other Products
H5N1 TaqMan RT-PCR Detection Kits
Product Info
Document
Product Info
Overview
Detection kits for H5N1
Available in TaqMan format for analysis
Influenza virus infection of birds, humans and other animals is a major public health problem worldwide. Influenza viruses are classified as either type A, B or C based on differences in their nucleoproteins and matrix proteins. The type A viruses are the most virulent human pathogens among the three influenza types and cause the most severe disease and epidemics. The different types can be further classified into subtypes based on antigenic differences in two surface glycoproteins; hemagglutinin and neuroamidase. All known subtypes of influenza A can be found in birds (H1-H16, N1-N9), while a limited number of the subtypes have been found in humans (H1-H3, N1 and N2). However, over the past few years, various subtypes of Influenza A viruses, including H5N1, have been reported to infect humans (WHO, 2006). In addition, the coexistence of human influenza viruses and avian influenza viruses may provide an opportunity for genetic material to be exchanged between these viruses. This could potentially create a new virulent influenza strain that is easily transmissible and lethal to humans (Food Safety Research Information Office, 2006). Thus, there is the need for sensitive diagnostic tests to allow for the rapid and early detection of these H5 influenza virus infections, to help reduce the risk of epidemics or pandemics in both animals and humans.
H5N1 TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
H5N1 TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective.
Our Individual Access Peel Heat Seal is a laminate seal compatible with polypropylene plates, featuring 96 individual foil seal spots or 12 strips of individual spots on a removable backing.
These seals result in individually sealed tubes/strips, and they can be removed from polypropylene plates by peeling, even with a plate which has been removed directly from -80°C storage.
Individual Access Peel Heat Seal forms a complete seal to a plate enabling very low temperature uses, including very low temperature storage, and high temperature uses, such as PCR (when used with a pressurized heated lid).
The seal demonstrates moderate solvent resistance and can be utilized for short term compound storage at room temperature.
This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer (using the 59-2005 Individual Access adapter).
Document
Peelable heat sealing foil, 96 individual seals with tabs, or 12 strips each covering 8 wells; suitable for very low-temperature storage/high temperature uses/PCR
DBCO-NHCO-PEG4-acid is an analog of DBCO-Acid with a hydrophilic PEG spacer arm, which improves water solubility. This reagent is a non-activated building block with enhanced solubility in aqueous media and can thus be used to derivatize amine-containing molecule through a stable amide bond. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
DBCO-NHCO-PEG4-acid is an analog of DBCO-Acid with a hydrophilic PEG spacer arm, which improves water solubility. This reagent is a non-activated building block with enhanced solubility in aqueous media and can thus be used to derivatize amine-containing molecule through a stable amide bond. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.