Isotherm3G is a mesophilic DNA polymerase, perfectly suited for Isothermal amplifications. Isotherm3G has been mutated to have improved reverse transcription activity. It synthesizes DNA from both DNA and RNA templates with a high strand displacement activity allowing simplified one-enzyme RT-LAMP reactions.
Detail
Isotherm3G is a mesophilic DNA polymerase, perfectly suited for Isothermal amplifications. Isotherm3G has been mutated to have improved reverse transcription activity. It synthesizes DNA from both DNA and RNA templates with a high strand displacement activity allowing simplified one-enzyme RT-LAMP reactions.
Isotherm3G exhibits 5’ to 3’ polymerase activity but lacks any exonuclease activity. The product components have been optimized and are perfectly suited for loop-mediated isothermal amplification (LAMP) with optimal reaction temperature at 65°C.
Isotherm3G DNA Polymerase utilizes an aptamer-based warm-start feature to prevent false amplification at low temperatures. For more information, please contact us.
The product is available also in bulk quantities with custom fillings and can be produced customized for example in a lyo-ready formulation.
Other Products
Leukocyte RNA Purification Kits
Product Info
Document
Product Info
Overview
Fractionate leukocytes from whole blood in minutes with provided RBC Lysis Buffer
Isolate total RNA, including microRNA, without phenol
Rapid and convenient spin-column format and 96-well plate for high throughput applications
Purified RNA is ready for any downstream application including RT-PCR, qRT-PCR, NGS, arrays and more. Find out more information on Norgen’s NGS services
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a rapid method for the isolation and purification of total leukocyte (white blood cell) RNA from mammalian blood samples. These kits are supplied with an RBC (red blood cell) Lysis Buffer for selective removal of red blood cells and fractionation of leukocytes by centrifugation. Isolation of leukocyte RNA results in improved expression profiling and other downstream applications by removing the masking effects of some RNAs which are very abundant in whole blood, such as globin mRNAs. These kits are able to isolate total leukocyte RNA, including both large mRNA and all small RNA species containing microRNA (miRNA) and small silencing RNA (siRNA). The purified RNA is of the highest quality and can be used in a number of downstream applications.
Leukocyte RNA Purification Kit (Spin Column)
This kit provides a rapid method for the isolation and purification of total leukocyte RNA from mammalian blood samples in 40 minutes. Allowable blood input ranges from 10 μL to 2 mL or 3 x 106 Leukocytes
Leukocyte RNA Purification Plus Kit (Plus)
Norgen’s Leukocyte RNA Purification Plus Kit provides a rapid method for the isolation and purification of total leukocyte (white blood cell) RNA from up to 3 mL of mammalian blood samples. Complete 10 purifications in as little as 40 minutes.
Purification is based on 96-well column chromatography using Norgen’s proprietary resin as the separation matrix. Purification can be performed using either a vacuum manifold or centrifugation. Norgen’s kit allows for the isolation of total leukocyte RNA, including all small RNA species. The purified RNA is of the highest quality and can be used in a number of downstream applications including real time PCR, reverse transcription PCR, northern blotting, RNase protection and primer extension, and expression array assays. Allowable blood input ranges from 10 μL to 1 mL or 1.5 x 106 Leukocytes.
Average Yield Human Blood (500 μL) Hamster Blood (100 μL)
1.5 μg 2.5 μg
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. The RBC Lysis Buffer should be stored at 4°C upon arrival.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 1 year under recommended storage conditions
Analyte:
D-Galacturonic Acid, D-Glucuronic Acid
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
5 to 150 µg of D-glucuronic acid or D-galacturonic acid per assay
Limit of Detection:
~ 15.5 mg/L
Reaction Time (min):
~ 10 min at 25oC or ~ 5 min at 37oC
Application examples:
Hydrolysates of plant material and polysaccharides and other materials.
Method recognition:
Novel method
The D-Glucuronic/D-Galacturonic test kit is a simple, reliable and accurate method for the measurement and analysis of D-hexuronic acids (specifically D-glucuronic acid and D-galacturonic acid) in plant extracts, culture media/supernatants and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The D-Glucuronic/D-Galacturonic test kit is a simple, reliable and accurate method for the measurement and analysis of D-hexuronic acids (specifically D-glucuronic acid and D-galacturonic acid) in plant extracts, culture media/supernatants and other materials.