The micro porous plate centrifuge adopts international advanced design concepts and manufacturing technology, with a smooth and beautiful appearance, compact and stable structure, adhering to the advantages of high universality and easy operation. It also has the functional characteristics of “smooth start” and “smooth braking”; This micro porous plate centrifuge is very suitable for 96 or 384 well and small capacity micro porous plates, as well as various standard PCR micro porous plates with or without skirts .
Detail
Product advantages
1. The instantaneous centrifugal function rises to the maximum speed for about 6 seconds, allowing for rapid detachment of hanging droplets from the wall;
2. Faster acceleration and deceleration rate, required to complete the experiment in a shorter time;
3. Door cover protection, overspeed and imbalance detection system, capable of real-time monitoring of the centrifugal process, ensuring the safe operation of the instrument; When the operation ends, an error occurs, or an imbalance occurs, the sound signal prompts, and the operation stops at the same time. The LCD displays the result code
Host Parameters
Product model
Mini-3
Input power supply
DC24V/2.75A
Input power
55W
Motor/Drive Method
DC24V brushless DC variable frequency motor
Display method
High brightness LCD screen
Effective centrifugal time
1-99min.1-59sec
speed
300~3000±15rpm
Speed step increase
10rpm
Maximum capacity
2 *96 well PCR plates/ELISA plates
MAX. RCF
608 xg
Misoperation/alarm failure
Sound prompt+display code
weight
3.9Kg
Noise
60dB (A)
Fastest acceleration time
<6s
Fastest deceleration time
<5s
Permissible ambient temperature/relative temperature
+5-40°C/80%
Other Products
IVD4173 HiPure Viral DNA/RNA Kit
Product Info
Document
Product Info
Introduction
This kit is used for extracting total viral nucleic acid from non-cell/low cell content biological samples such as body fluid, serum, plasma, urine, immersion solution, tissue homogenate supernatant, culture supernatant, etc., the extracted products can be used for clinical in vitro detection.
Details
Specifications
Features
Specifications
Main Functions
Extract viral RNA/DNA from non-cell/low cell content biological samples
Applications
RT-PCR,PCR,NGS
Products
Viral total nucleic acid
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Cell-free body fluid such as plasma, serum, soaking solution and tissue homogenate supernatant
Sample amount
200μl
Yield
2-10μg
Elution volume
≥30μl
Time per run
≤30 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
This product is based on silica gel purification. The sample is lysed and digested with lysate and protease, DNA / RNA is released into the lysate. Transfer to an adsorption plate and filter column. DNA/RNA is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, DNA / RNA was finally eluted with low-salt buffer (10 Mm Tris, pH 8.0).
Advantages
Fast – several samples can be extracted in 20 minutes by column method
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Safe – no phenol chloroform extraction required
Sensitive – DNA/RNA can be recovered at the level of PG
High yield – carrier RNA contained in the product maximize the recovery of trace nucleic acid
Kit Contents
Contents
IVD4173
Purification Times
100 Preps
HiPure Viral Mini Column
100
2ml Collection Tubes
200
PK/Carrier RNA
50 mg
Protease Dissolve Buffer
5 ml
Buffer AL
30 ml
Buffer MW1*
44 ml
Buffer MW2*
50 ml
RNase Free Water
15 ml
Storage and Stability
Proteinase K should be stored at 2–8°C upon arrival. However, short-term storage (Proteinase K up to 8 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for 18 months under these conditions.
Experiment Data
Document
This kit is used for extracting total viral nucleic acid from non-cell/low cell content biological samples such as body fluid, serum, plasma, urine, immersion solution, tissue homogenate supernatant, culture supernatant, etc., the extracted products can be used for clinical in vitro detection.
Usages: As a solidifying agent, thickening agent, emulsifying agent for preparing microbiological culture media, bio-engineering, and food manufacture.
Technical specification: Gel strength—————————>500g/cm² Moisture——————————-<15% Ash————————————-<5% Insoluble substance in hot water—-<1% Gelation point————————-32-39℃ As—————————————<1mg/Kg Pb—————————————<10mg/Kg
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light.
This Kit is designed to purify genomic DNA and total RNA simultaneously from a single biological sample. Lysate is first passed through a DNA spin column to selectively isolate DNA and then through an RNA column to selectively isolate RNA. Pure DNA and RNA are purified from the entire sample, in contrast to other procedures where either the biological sample or the purified total nucleic acids is divided into two before being processed separately. The kit is compatible with small amounts of a wide range of animal cells and tissues.
Details
Specifications
Features
Specifications
Main Functions
Co-isolation DNA and RNA(not include miRNA) from a single sample (cells, soft tissue, plant sample)
Applications
RT-PCR, cDNA synthesis, PCR andsecond-generation sequencing, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Soft tissue samples (viscera, excluding skin andmuscle), cultured cells and common plant tissues
Sample amount
Soft Tissue: < 30mg, Cell: <1 x 107, Plant: <100mg
Yield
DNA: 1 – 20 μg, RNA: 3 – 100 μg
Principle
The Kits are designed to purify both genomic DNA and total RNA from the same cellor tissue sample. Samples are first lysed and homogenized. The lysate is passed through a DNA Mini column and bind DNA. Ethanol is added to the flow-through and the sample is applied to an RNA column. DNA/RNA binds to the membrane and contaminants are washed away. High-quality RNA is eluted in as little as 30µl water using the Kit. High-quality DNA is eluted in as little as 50µl water using the Kit.
Advantages
High quality – high purity total RNA / DNA can be directly used in a variety of downstream applications
Fast – column method can complete the extraction of several samples in 30 minutes
Safe – no phenol chloroform extraction required
Simultaneous extraction- simultaneously isolate DNA and RNA from one sample
Kit Contents
Contents
R511102
R511103
Purification Times
50 Preps
250 Preps
HiPure DNA Mini Columns
50
250
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
100
2 x 250
Buffer RLC
50 ml
200 ml
Buffer DW1
30 ml
150 ml
Buffer RW1
30 ml
150 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Buffer AE
10 ml
50 ml
Storage and Stability
HiPure DNA/RNA Kit can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This Kit is designed to purify genomic DNA and total RNA simultaneously from a single biological sample. Lysate is first passed through a DNA spin column to selectively isolate DNA and then through an RNA column to selectively isolate RNA. Pure DNA and RNA are purified from the entire sample, in contrast to other procedures where either the biological sample or the purified total nucleic acids is divided into two before being processed separately. The kit is compatible with small amounts of a wide range of animal cells and tissues.