BI3 base.column sunnort unner and ower light source 3 WLED
●
●
BL3-A base vertical arm bracket upper and lower light source 3 WLED
●
●
B3 base column support has no light source
●
●
External light source
LED illumination
Q
Q
Q
O
Optiona
Photography,camera accessories CCD Coupler
o
o
o
o
o
o
Optional
Display attachment Monitor
Other Products
PACE® NANO GENOTYPING MASTER MIX
Product Info
Document
Product Info
ABOUT
Step into the future of high-throughput PCR genotyping with PACE Nano! Backed by decades of expertise in high-throughput genotyping reagent manufacturing, our groundbreaking product is engineered specifically to excel in low and ultra-low volume reactions. Say goodbye to performance variability as PACE Nano Genotyping Master Mix and PACE Genotyping Assays raise the bar for reliability and performance in the field.
With superior cost-effectiveness and versatile compatibility, PACE Nano Genotyping Master Mix ensures consistent results across diverse platforms, samples, and markers, including 384- and 1536-well PCR, Array Tape™, SNPline™ and Gene Mathematica from HC Scientific, available from 3CR Bioscience, supporting reaction volumes as low as 0.8 µL. Join the revolution today and elevate your research with PACE Nano.
Cost-Effective: Produce more high-quality data faster and at a much lower cost compared to competitors, reducing reagent expenses without compromising on quality.
Optimised for Low and Ultra-Low Volume PCR Genotyping: PACE Nano Genotyping Master Mix is specifically tailored for enhanced performance in miniaturised PCR genotyping, for reaction volumes as low as 0.8 µL and for high-throughput and automated processing with accurate, reliable results.
Consistent Data Across Assays: PACE Nano reduces variability in assay performance, enhancing the robustness and efficiency of high throughput, miniaturised and automated workflows.
Backed by 20 Years of Expertise: Designed and manufactured with 20 years of experience in high-throughput genotyping reagents, ensuring reliability and quality.
Scalability: Our PACE® genotyping reagents are platform agnostic, so you can adapt to changing throughput requirements effortlessly, ensuring flexibility and efficiency at every stage of your genotyping workflow.
PACE Nano Global Product Support: Benefit from a stable supply chain and unparalleled global product support, tailored to your needs regardless of size or throughput. Supported by the highest quality-assurance processes, ensuring reliability and consistency.
REQUIRED COMPONENTS
qPCR machine or Thermocycler + Fluorescent plate reader
PCR plate or equivalent and appropriate optically clear seal
Livestock Disease Kit with African swine fever virus Test Kit for Nucleic Acid Detection
Product parameters:
Kit composition(WLRE8208KIT 48T/Pack)
Composition
Content
E buffer
1 mL×2 Tubes
B buffer
150 μL×1Tube
Positive control template
100 μL×1Tube
Reagents
48T
Product features and advantages:
Product features and advantages
Features
Advantages
High sensitivity
1 copies/ml
Strong specificity
Specificity is superior to PCR
Short reaction time
20min
Polymorphic reagent
Liquid, freeze-dried powder, freeze-dried ball
Easy to operate
Few steps of liquid dispensing; It is even possible to add only samples and amplify to get the resultsDesign of primers and probe is simple
Easy to store and transport
It is best preserved at -20℃, and can be stored at room temperature for up to 30 days in a cool place away from light.The freeze-dried form has a long storage time and is convenient for transportation
Low requirements on equipment
Applicable to Applied Biosystems 7500, QuantStudio 3/5, QuantStudio 6/7 Flex fluorescence quantitative PCR instrument;Applicable to our WL-16-III and other isothermal fluorescence detector
Product application:
Application
Ultra-clean laboratory
African Swine Fever Virus Isothermal Detection
Indoor
Operation procedure and process:
Operation procedure and process:
Take out the liquid components of the kit in advance, thaw at room temperature, and shake to mix.
Prepare freeze-dried reagents according to the number of samples to be tested, negative and positive controls, and add 37.5 μL E buffer to each freeze-dried reagent.
Select the appropriate nucleic acid extraction method and reagent to extract the sample nucleic acid
Add 10 μL nucleic acid template to the reaction tube (the amount of template can be adjusted to be filled with sterile water; That is, 10 μL nucleic acid template plus sterile water), 10 μL positive control template was added to positive control, and 10 μL sterile water was added to negative control
Add 2.5μL B buffer to each reaction tube and close the tube cap (for multiple reactions, it is recommended to add B buffer to the inside of the tube cap)
Thoroughly mix the reaction tube upside and down for 8-10 times. After mixing, shake (or rapidly centrifuge) the reaction liquid to the bottom of the tube and transfer it to the amplification zone.
Performence Comparison Data:
No.
TT value
Template concentration
Result determination
1
4.2
10-1
Positive
2
5.5
10-2
Positive
3
10.2
10-3
Positive
4
17.0
10-4
Positive
5
12.0
10-5
Positive
6
–
10-6
Negative
7
–
10-7
Negative
8
Negative control
Negative
Support and Services:
Livestock Disease Kit Technical Support and Services
We provide technical support and services for our Livestock Disease Kit. We are committed to helping you get the most out of your product and ensuring your satisfaction with our products and services.
Our technical support staff is available to answer any questions you may have about the product.
We offer online tutorials and user guides to help you understand the product better.
We provide technical assistance to help troubleshoot any issues you may be having with the product.
We offer a warranty on our products.
If you have any questions or need technical support, please do not hesitate to contact us. We are here to help you make the most of your Livestock Disease Kit.
FAQ:
Q: What diseases can Livestock Disease Kit detect? A: Livestock Disease Kit can detect different infectious diseases, such as Foot and Mouth Disease, Bluetongue Disease, Bovine Viral Diarrhea.
Q: How does Livestock Disease Kit work? A: Livestock Disease Kit uses advanced MIRA technology to amplify the target DNA/RNA targent sequences , and detect the disease by analyzing the amplified sequences.
Q: How long does it take to get results from Livestock Disease Kit? A: Livestock Disease Kit can give a result within 5-20 mins.
Q: What type of sample is suitable for Livestock Disease Kit? A: Livestock Disease Kit is suitable for blood, serum, and tissue samples.
Q: Does Livestock Disease Kit require professional equipment? A: No, Livestock Disease Kit does not require any professional equipment,can use with our isothermal equipment or pcr machine
Document
Livestock Disease Kit with African swine fever virus Test Kit for Nucleic Acid Detection
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.
Details
Specifications
Features
Specifications
Main Functions
Extract viral RNA from 140μl cell-free samples
Applications
RT-PCR, Northern hybridization, and various virus detection
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Cell-free body fluid or culture medium
Sample amount
140μl
Elution volume
≥15μ
Time per run
≤25 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such as guanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein and other impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
The sample is homogenized and lysed in the lysate, and RNA is released into the lysate. The high concentration of guanidine isothiocyanate contained in the lysate denatured and inactivated endogenous or exogenous RNase, while RNA is protected from degradation. The lysate is centrifuged to remove insoluble impurities. After adding ethanol to adjust the binding conditions, it is transferred to the column for filtration. RNA is adsorbed on the membrane of the column, while protein is removed without adsorption. The column is washed with buffer VHB to remove protein and other impurities, washed with buffer RW2 to remove salt. Finally the RNA is eluted by RNase free water. The eluted RNA can be directly used in RT-PCR, Northern blot, poly-A purification, in vitro translation, etc.
Advantages
Fast – several samples can be extracted in 20 minutes by column method
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
High yield – carrier RNA contained in the product maximize the recovery of trace nucleic acid
Kit Contents
Contents
R417102
R417103
Purification Times
50 Preps
250 Preps
HiPure Viral Micro Columns
50
250
2ml Collection Tubes
100
500
Buffer VRL
50 ml
200 ml
Carrier RNA
310 µg
3 x 310 µg
Buffer VHB*
13 ml
110 ml
Buffer RW2*
20 ml
2 x 50 ml
Nuclease Free Water
10 ml
30 ml
Storage and Stability
Carrier RNA should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under theseconditions
Document
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.