Product Description
High Sensitivity RNA Amplification With Improved Detection Isothermal Kit
Applicable equipment:
It is recommended to use the Isothermal fluorescence detector developed by Amp-future, which is also suitable for fluorescence quantitative PCR apparatus with market known brands.
Kit Storage and term of Validity
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature: at room temperature and constant temperature (generally 39℃~42℃), with the help of auxiliary proteins and single-strand binding proteins,the recombinase and primers form a complex;Source search and combine the target homology domain, at this time,a D-loop region is formed at the homology position and strand exchange begins;along with the dissociation of the recombinase from the complex,the polymerase also binds to the 3′ end of the primer and begins chain extension. At the same time, relying on the function of exonuclease, adding specific molecular probes designed according to the template, and using fluorescence monitoring equipment can realize real-time monitoring of the amplification process of the target fragment.
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
Technical Parameters:
Parameters | Details |
---|---|
Product Name | DNA Isothermal Amplification Kit EXO |
Manufacturer | Amp-future |
Storage Temperature | -20°C |
Kit Components | Enzymes, Buffers ,Reagents |
Packaging | 48 Tests/box |
Detection Limit | 500-1000copies/µL |
Shipping | ICE |
Test Time | 5-20mins |
Isothermal nucleic acid Applications
Suitable for DNA isothermal rapid amplification kit(fluorescent type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
Fluorescent Probe:Require the suitable length is 46-52nt.
DNA fluorescent kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.
It is recommended to use the Isothermal fluorescence detector developed by Amp-future, which is also suitable for fluorescence quantitative PCR apparatus with market known brands.
The Opentrons Flat Bottom Aluminum Block can be placed directly on the OT-2/Opentrons Flex deck or on the Opentrons Temperature Module. This block can hold flat bottom plates and other flat labware at constant temperature. The aluminum block holds temperatures between 4°C and 95°C when used with the Opentrons Temperature Module (GEN2). This version is only compatible for the Opentrons Flex.
The Opentrons Flat Bottom Aluminum Block can be placed directly on the OT-2/Opentrons Flex deck or on the Opentrons Temperature Module. This block can hold flat bottom plates and other flat labware at constant temperature. The aluminum block holds temperatures between 4°C and 95°C when used with the Opentrons Temperature Module (GEN2). This version is only compatible for the Opentrons Flex.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Primer and probe mix (150 reactions)
Reverse Transcription, target specific primers (RNA genome viruses only)
Copy number standard curve (sufficient for multiple standard curves)
Internal extraction control – Read through VIC channel*
Endogenous control (150 tests)
RNAse/DNAse free water
*alternative fluorophores available on request
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio