

Opentrons Flex 8-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
Opentrons Flex 8-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
MagZol Reagent is a reagent system for the isolation of total RNA from cells and tissues. The reagent, a single-phase solution consisting of phenol and guanidine isothiocyanate, is modification of the single-step RNA isolation method developed by Chomczynski and Sacchi. The sample is homogenized and lysed in MagZol Reagent which maintains the integrity of the RNA, while disrupting and denaturing endogenous RNases and other cellular components. Extraction of the lysate with chloroform further denatures proteins and separates the mixture into an organic and an aqueous phase. RNA remains exclusively in the aqueous phase, and is subsequently recovered by isopropanol.
This method is suitable for small quantities of tissue (<100mg) and cells (<5 X106), and large quantities of tissue (up to 1g) and cells (<108), of human, animal, plant, or bacterial origin. The simplicity of the MagZol Reagent method allows simultaneous processing of a large number of samples. The entire procedure can be completed in one hour. Total RNA prepared in this manner can be used for Northern blot analysis, dot blot hybridization, poly(A) + selection, in vitro translation, RNase protection assay, and molecular cloning. For use in amplification by thermal cycling, treatment of the isolated RNA with RNase-free DNase I is recommended when the two amplimers lie within a single exon.
Specifications
| Features | Specifications |
| Main Functions | Extract RNA from liquid samples by salting out method |
| Applications | RT-PCR, Northern hybridization, poly (a) enrichment, etc. |
| Purification technology | Acid phenol guanidine isothiocyanate |
| Process method | Manual (centrifugation) |
| Sample type | Various liquid samples |
| Sample amount | Flexible |
| Elution volume | Variation with sample size |
| Time per run | Variation with sample size |
Storage and Stability
MagZol Reagent should be stored at 2-8°C upon arrival and is stable for at least 24 months under the condition. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect its performance.
MagZol Reagent is a reagent system for the isolation of total RNA from cells and tissues. The reagent, a single-phase solution consisting of phenol and guanidine isothiocyanate, is modification of the single-step RNA isolation method developed by Chomczynski and Sacchi. The sample is homogenized and lysed in MagZol Reagent which maintains the integrity of the RNA, while disrupting and denaturing endogenous RNases and other cellular components. Extraction of the lysate with chloroform further denatures proteins and separates the mixture into an organic and an aqueous phase. RNA remains exclusively in the aqueous phase, and is subsequently recovered by isopropanol.
The Permagen 384-well post magnet plate was designed for use in manual or automation applications for Low Elution high throughput PCR
Magnetic beads are pulled midway up onto well wall to help eliminate accidental bead pellet disruption and to achieve lower volumes
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, compatible with any magnetic beads, and integrated cushion base to help aid in robot/ consumable inconsistencies
MSP384LE
Maximum – 39 µL
Minimum – 5 µL
The Permagen 384-well post magnet plate was designed for use in manual or automation applications for Low Elution high throughput PCR