Norgen’s Saliva/Swab RNA Purification Kits provide a rapid method for the purification of total RNA from non-preserved saliva and nasal/throat swabs, and from preserved saliva collected on Norgen’s Saliva RNA Collection and Preservation Devices (Cat. RU53800) or preserved swabs collected in Norgen’s Total Nucleic Acid Preservative Tubes (Cat. 69200). Purification is based on using Norgen’s proprietary resin separation matrix. RNA is preferentially purified from other cellular components such as proteins, without the use of phenol or chloroform. The kit allows the purification of total RNA, including viral and bacterial RNA, irrespective of size or GC content. The purified RNA is eluted in an Elution Solution that is compatible with all downstream applications including PCR, qPCR, methylation-sensitive PCR and Southern Blot analysis, microarrays, and NGS.
This kit offers a range of elution volumes, with a minimum elution volume of 75 μL and a maximum elution volume of 100 μL. Complete 10 purifications in as little as 15 minutes.
High throughput 96-well plate format for rapid purifications with very consistent well-to-well RNA isolation. Purified RNA is suitable for a variety of downstream applications , including Small RNA Sequencing. Find out more information about Norgen’s NGS Services.
Figure 1 / 8
Click for expanded view
Kit Specifications | |
Sample Volume Range | 250 µL |
Size of RNA purified | All sizes, including small RNA (<200 nt) |
Minimum Elution Volume | 75 µL |
Maximum Elution Volume | 100 µL |
Time to complete 96 purifications | 30 minutes |
Average Yield | ≥ 1 µg **varies from sample to sample |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Kit Component | Cat. 69100 (50 preps) | Cat. 69300 (192 preps) |
---|---|---|
Lysis Buffer A | 30 mL | 100 mL |
Solution WN | 18 mL | 55 mL |
Wash Solution A | 18 mL | 2 x 38 mL |
Elution Solution A | 6 mL | 20 mL |
Mini Spin Columns | 50 | – |
Collection Tubes | 50 | – |
Elution Tubes (1.7 mL) | 50 | – |
96-Well Isolation Plate | – | 2 |
96-Well Collection Plate | – | 2 |
96-Well Elution Plate | – | 2 |
Adhesive Tape | – | 4 |
Product Insert | 1 | 1 |
Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map