K-LATE
SKU: 700004310
50 assays (manual) / 500 assays (microplate) / 450 assays (auto-analyser)
Content: | 50 assays (manual) / 500 assays (microplate) / 450 assays (auto-analyser) |
Shipping Temperature: | Ambient |
Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
Stability: | > 1 year under recommended storage conditions |
Analyte: | L-Lactic Acid |
Assay Format: | Spectrophotometer, Microplate, Auto-analyser |
Detection Method: | Absorbance |
Wavelength (nm): | 340 |
Signal Response: | Increase |
Linear Range: | 0.3 to 30 µg of L-lactic acid per assay |
Limit of Detection: | 0.21 mg/L |
Reaction Time (min): | ~ 10 min |
Application examples: | Wine, beer, soft drinks, milk, dairy products (e.g. cream, milk / whey powder, cheese, condensed milk and yogurt), foods containing milk (e.g. dietetic foods, bakery products, baby food, chocolate, sweets and ice-cream), egg, egg products (e.g. egg powder), baking additives, vinegar, fruit and vegetables, processed fruit and vegetables (e.g. tomatoes), meat products, food additives, feed, paper (and cardboard), cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.). |
Method recognition: | Methods based on this principle have been accepted by DIN, GOST, IDF, EEC, EN, ISO, OIV, IFU, AIJN and MEBAK |
The L-Lactic Acid (L-Lactate) Assay Kit is used for the specific measurement and analysis of L-lactic acid (L-lactate) in beverages, meat, dairy and food products.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Explore our complete list of organic acid assay kits.
Advantages
The L-Lactic Acid (L-Lactate) Assay Kit is used for the specific measurement and analysis of L-lactic acid (L-lactate) in beverages, meat, dairy and food products.
Description
The ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and template. The master mix features high sensitivity and signal intensity as well as low background and better compatibility with cDNA templates derived directly from reverse transcription reaction mixture. The ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) contains hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. This master mix allows for sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules. With inert smart blue contrast dye, the ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Q-PCR Master Mix is also compatible with a ROX reference dye if recommended by the manufacturer of the qPCR system.
Features
Storage
Protected from light.
Aliquot to avoid multiple freeze-thaw cycles.
-20°C for 12 months
The ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and template. The master mix features high sensitivity and signal intensity as well as low background and better compatibility with cDNA templates derived directly from reverse transcription reaction mixture. The ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) contains hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. This master mix allows for sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules. With inert smart blue contrast dye, the ExcelTaq™ 2X Q-PCR Master Mix (SYBR, no ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Q-PCR Master Mix is also compatible with a ROX reference dye if recommended by the manufacturer of the qPCR system.
Recombinant adeno-associated virus (AAV) vectors are highly promising tools for both in vitro and in vivo gene transfer. Norgen’s AAV Purification Kits provide fast and simple procedures for concentrating and purifying AAV vectors from cell lysate and cell culture media. Purification is based on precipitation onto Norgen Biotek’s proprietary resin. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. AAV vector purified in this manner is highly active for use in in vitro and in vivo transduction experiments.
AAV Purification Kit
Norgen’s AAV Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant (SN) or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit. Up to 33X sample concentration.
AAV Purification Mini Kit
Each spin column is able to concentrate and purify AAV from 0.5-8 mL of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (200 µL). Preparation time for 4 samples is 1.5 hours, with 45 minutes of hands-on time.
AAV Purification Midi Kit
Each spin column is able to concentrate and purify AAV from 8 mL up to 45 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1 mL). The kit may be used to purify up to 8 x 25 mL or 4 x 45 mL of samples using the included columns. Preparation time for 4 samples is approximately 2 to 2.5 hours, with 1.5 hours of hands on time.
AAV Purification Maxi Kit (Slurry Format)
Each spin column is able to concentrate and purify AAV from 45 mL to 90 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 200X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1-10 mL) using the optional concentration step. The kit may be used to purify up to 1 x 900 mL samples or 10 x 45-90 mL samples using the included columns. Preparation time for 1 x 900 mL sample is approximately 2.5 to 3.5 hours, with an optional concentration step requiring an additional 30 min.
Figure 1 / 10
Click for expanded view
Kit Specifications | |
Column Binding Capacity | At least 1 x 1010 AAV particles as determined by qPCR |
AAV Vector Serotype | Any |
Average Recovery | > 80% |
Input Type | Cells, media, or mixed |
Input Volume | 8 mL – 45 mL |
Minimum Elution Volume | 1 mL |
Time to Complete 4 Purifications | 2 – 2.5 hours |
Storage Conditions and Product Stability
DNAse I and RNAse A should be stored at -20°C upon arrival. Elution Buffer O should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. Once opened, the solutions should be stored at 4°C. This kit is stable for 1 year after the date of shipment.
Component | Cat. 66100 (15 preps) | Cat. 63200 (20 preps) | Cat. 63300 (4-8 preps) | Cat. 63250 (1-10 preps) |
---|---|---|---|---|
Lysis Buffer S | 5.5 mL | 5.5 mL | 5.5 mL | 20 mL |
DNAse I | – | 2 x 25 uL | 2 x 25 uL | 210 μL |
RNAse A | – | 60 μL | 60 μL | 240 μL |
HL-SAN Nuclease | 102 μL | – | – | – |
Binding Buffer A | 20 mL | 4 mL | 4 mL | 2 x 8 mL |
Purification Solution C | 60 mL | – | – | – |
Purification Solution D | 130 mL | – | – | – |
Wash Solution C | 2 x 130 mL | 60 mL | 60 mL | 3 x 60 mL |
Slurry E | 12.5 mL | – | – | 2 x 14.5 mL |
Elution Buffer O | 66 mL | 8.5 mL | 8.5 mL | 66 mL |
Protein Neutralizer | 4 mL | 4 mL | 4 mL | 4 mL |
Spin Columns | – | 20 | – | – |
Mini Spin Columns | – | 20 | – | – |
Midi Spin Columns (grey contents) with Collection Tubes | – | – | 8 | 10 |
Midi Spin Columns (white contents) with Collection Tubes | – | – | 8 | – |
Maxi Spin Columns (grey contents) with Collection Tubes | – | – | – | 10 |
Maxi Spin Columns (white contents) with Collection Tubes | – | – | – | 10 |
Collection Tubes | – | 40 | – | – |
Elution tubes (1.7 mL) | 50 | 20 | – | – |
Midi Elution tubes (15 mL) | – | – | 8 | 10 |
Maxi Elution tubes (50 mL) | – | – | – | 10 |
Product Insert | 1 | 1 | 1 | 1 |
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio