K-FRGLQR
SKU: 700004283
1100 assays (microplate) / 1100 assays (auto-analyser)
Content: | 1100 assays (microplate) / 1100 assays (auto-analyser) |
Shipping Temperature: | Ambient |
Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
Stability: | > 6 months under recommended storage conditions |
Analyte: | D-Fructose, D-Glucose |
Assay Format: | Microplate, Auto-analyser |
Detection Method: | Absorbance |
Wavelength (nm): | 340 |
Signal Response: | Increase |
Linear Range: | 0.4 to 20 µg of D-glucose plus D-fructose per assay |
Limit of Detection: | 133 mg/L |
Reaction Time (min): | ~ 13 min |
Application examples: | Wine, beer, fruit juices, soft drinks, milk, jam, honey, dietetic foods, bread, bakery products, candies, desserts, confectionery, ice-cream, fruit and vegetables, condiments, tobacco, cosmetics, pharmaceuticals, paper and other materials (e.g. biological cultures, samples, etc.). |
Method recognition: | Methods based on this principle have been accepted by AOAC, EN, NEN, NF, DIN, GOST, OIV, IFU, AIJN, MEBAK and IOCCC |
This product has been discontinued, you may be interested in the following replacement product K-FGLQR; 700007621)
The D-Fructose/D-Glucose (Liquid Ready) test kit is a rapid, reliable and accurate method for the specific measurement and analysis of D-fructose and D-glucose in wine, beverages, foodstuffs and other materials. Supplied as a “ready to use” liquid stable formulation that is suitable for auto-analyser and microplate formats.
Find more of our monosaccharide and oligosaccharide assay kits.
Advantages
This product has been discontinued, you may be interested in the following replacement product K-FGLQR; 700007621)
Description
ExcelRT™ Reverse Transcription Kit is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with oligo (dT)20 and random hexamers, which are used to synthesize cDNA from poly(A) tailed mRNA and total RNA, respectively.
Features
Application
Storage
-20°C for 24 months
ComponentVolume ExcelRT™ Reverse Transcriptase (200 U/μl) 100 μl RNase Inhibitor (20 U/μl)100 μl 5X RT Buffer (DTT)500 μl dNTPs Mix (10 mM each)200 μl Oligo (dT)20 (50 μM)100 μl Random Hexamers (100 μM)100 μl DEPC-Treated H2O 1 ml x 2 |
Storage Buffer
Reverse Transcriptase: 20 mM Tris-HCl (pH 7.5), 200 mM NaCl, 0.1 mM EDTA, 1 mM DTT, stabilizer and 50% (v/v) glycerol
RNase Inhibitor: 40 mM HEPES-KOH (pH 7.5), 100 mM KCl, 8 mM DTT, 0.1 mM EDTA, stabilizer and 50% (v/v) glycerol
5X RT buffer (DTT)
250 mM Tris-HCl (pH 8.3), 375 mM KCl, 15 mM MgCl2 and 50 mM DTT
Storage
-20°C for 24 months
ExcelRT™ Reverse Transcription Kit is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with oligo (dT)20 and random hexamers, which are used to synthesize cDNA from poly(A) tailed mRNA and total RNA, respectively.
The kit is developed for RNA quantification. The RNA Quantification HS kit includes HS Dye, HS Dilution Buffer, and two RNA Standards. Simply dilute the HS Dye with the HS Dilution Buffer, add RNA sample, then read the concentration using the Qubit Fluorometer. The assay is accurate for RNA concentrations from 250 pg/µL to 100 ng/µL (Figure 1). The RNA Quantification High Sensitivity Kit has several advantages over traditional RNA quantitation such as stability, sensitivity, and contaminant tolerance.
Features
The performance of the BioDynami RNA Quantification HS kit is nearly identical to that of Thermo Fisher’s Qubit RNA HS kit (figure below).
Common contaminants such as detergents, solvents, salts, free nucleotides, or protein are well tolerated in the assay (Table 1).
Qubit is a registered trademark of Thermo Fisher Scientific.
The kit is developed for RNA quantification. The RNA Quantification HS kit includes HS Dye, HS Dilution Buffer, and two RNA Standards. Simply dilute the HS Dye with the HS Dilution Buffer, add RNA sample, then read the concentration using the Qubit Fluorometer. The assay is accurate for RNA concentrations from 250 pg/µL to 100 ng/µL (Figure 1). The RNA Quantification High Sensitivity Kit has several advantages over traditional RNA quantitation such as stability, sensitivity, and contaminant tolerance.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio