Character
High flatness sample shelf:
Silicone oil thermal conductive shelf, high-precision processing method of upper and lower clamping, shelf temperature uniformity can reach ±0.5°c
Integrated cavity:
Integrated chamber, the shelf and cold trap are located in the same chamber, the steam conduction is faster and the freeze-drying effect is better
Refrigerating and heating control system:
Using thermally conductive silicone oil with a high temperature range and precise PID control algorithm, the control accuracy can reach ±0.5°C. Sample shelf temperature range: -70°C~ +80°C
Freeze-drying endpoint testing system:
The pressure comparison method is used to determine the freeze-drying end point. The freeze-drying end point test can be automatically performed after the analytical drying stage to ensure that the moisture content of the material reaches the standard requirements.
Vacuum precise control and adjustment system:
The sublimation and analytical drying processes are controlled and adjusted with high precision to make the freeze-drying process warmer and the sample sublimation more reliable.
Pulse backfill system:
Three backfilling modes can be selected: slow, medium and fast, which avoids the problem of effective substances being blown away and lost due to the aeration of granular and flocculent materials after freeze-drying.
Manual automatic mode selection:
Manual mode is used to explore process parameters (strong human intervention), automatic mode is used in the mature stage of the process, one-click operation, simple and convenient
Data recording and analysis system:
Through the PC host computer, all operating parameters and background parameters of the equipment can be recorded in real time, and all parameter action changes and action changes of operating components can be recorded.
Freeze-drying process recipe storage function:
The host can store 60 sets of fixed or user-defined freeze-drying process recipes, and the PC can store >10,000 programs (depending on the computer hard drive)
Eutectic point test function:
The eutectic point temperature of the product can be tested offline and online, and the spectrum can be analyzed manually or automatically (optional)
Remote control system:
The operating status of the device can be monitored remotely, and the device can be monitored in real time via WiFi or the cloud.
Mobile phone monitoring system:
You can monitor the operating status of the equipment with your mobile phone, which is simple and convenient (optional)
Cold trap defrost system:
The hot air defrosting method has high safety performance; the defrosting speed is fast, which solves the inconvenience caused by traditional immersion defrosting.
Parameter
Model | EX2 | EX5 | EX8 | EX12 |
Freeze-area | 0.24m² | 0.38m² | 0.96m² | 1.45m² |
Ice coagulating capacity | 4kg | 9kg | 12kg | 18kg |
Shelf temperature | 70℃~+80℃ | -65℃~+70℃ | ||
Cold trap temperature | -70/-90℃ | -70/-90℃ | -70℃/-90℃ | -70℃/-85℃ |
Cold trap volume | 9L | 15L | 18L | 30L |
chamber type | single | double | ||
Shelf size | 275*400 mm | 275*400 mm | 365*465 mm | 365*465 mm |
Shelf spacing | 100mm(adjustable) | 100mm(adjustable | 70mm(adjustable) | 70mm(adjustable) |
Sample quantity (4R Cillin bottle) | 558 | 1395 | 2630 | 4230 |
Shelf heating and cooling method | Thermal conducting silicone oil medium(temperature resistance: -100℃~+600℃) | |||
Chamber and shelf surface | High vacuum stainless steel tube/KF25-40 | |||
vacuum line | High vacuum stainless steel tube | KF50 | ||
External valve port | 6/ | 12/ | 18/ | 一 |
equipment power | 3.8kw | 5.5kw | 6.5kw | 8kw |
equipment size | 700*588*1600 mm | 1030*700*1630 mm | 1030*700*1850 mm | 1500*850*1900 mm |
Capping mode | Hydraulic system gland device/no gland | hydraulic pressure | ||
Suitable clean room | Suitable | |||
Vacuum sensor type | Pirani Vacuum sensor/Capacitive vacuum sensor | |||
Remote control and alarm | Support 2G/4G/GSM/Wi-Fi | |||
Terminal judgment function | Pressure contrast method | Pressure test/pressure contrast method | ||
Freeze dryer front door cover | Stainless steel/Plexiglass | Stainless steel | ||
Inert gas filling | (Optional) Sufficient amount and time for the program to run itself | |||
User function customization | Can be customized and modified according to user needs | |||
sterilization method | H2O2/steam sterilization |
Sample type purification kit guide
The 16S V1-V2 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V1-V2 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.
The 16S V1-V2 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V1-V2 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.
Figure 1 / 3
Click for expanded view
Minimum amount of starting material: | 2.5 µL of DNA (5 ng/µL) |
Time to complete library preparation: | 4 hours |
Storage Conditions and Product Stability
Norgen’s 16S V1-V2 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components should remain stable for at least 1 year when stored at the specified storage conditions.
Step | Component | Cat. 70100 (24 preps) | Cat. 70110, 70120, 70130, 70140 (96 preps) |
---|---|---|---|
Amplicon PCR (PCR 1) | MGX Master Mix | 330 µL | 1,320 µL |
16S V1-V2 Primer Mix | 70 µL | 280 µL | |
Index PCR (PCR 2) | Indexing Master Mix | 660 µL | 2 x 1,320 µL |
N7xx Index Primer | 50 µL | 50 µL | |
S5xx Index Primer | 70 µL | 70 µL | |
PCR Clean-Up | Resuspension Buffer | 2 x 1,250 µL | 2 x 5,000 µL |
Nuclease-free water | 1,250 µL | 1 x 6,000 µL |