These kits are designed for the rapid spin column removal of endotoxins from previously purified DNA. Norgen’s spin columns bind DNA while endotoxins, salts and other contaminants are washed away. These kits reduce endotoxins to 0.1 EU/μg DNA or less providing plasmid DNA that is immediately ready for transfections or other endotoxin-sensitive applications. Typical recovery of DNA is >90% of the starting sample.
Endotoxin Removal Kit (Mini)
This kit is designed for the rapid spin column removal of endotoxins from up to 25 µg of previously purified DNA. The convenient spin column procedure can be completed in approximately 20 minutes.
Endotoxin Removal Kit (Midi)
This kit is designed for the rapid spin column removal of endotoxins from up to 200 μg of previously purified DNA. The convenient spin column procedure can be completed in approximately 30 minutes.
Endotoxin Removal Kit (Maxi)
This kit is designed for the rapid spin column removal of endotoxins from up to 1 mg of previously purified DNA. The convenient spin column procedure can be completed in approximately 30 minutes.
About Endotoxins
Endotoxins (also called lipopolysaccharides), are cell-membrane components of Gram-negative bacteria such as E. coli. Endotoxins are released during the lysis step of plasmid purification and significantly reduce transfection efficiencies in endotoxin sensitive cell lines. Therefore, the removal of endotoxins from plasmid preparations is often necessary prior to the use of the DNA in such downstream applications.
Figure 1 / 2
Click for expanded view
Kit Specifications | |
Maximum DNA Input | 25 μg |
Final Endotoxin Level | ≤ 0.1 EU/µg DNA |
Size of DNA Purified | Up to 13,000 bp |
Maximum DNA Volume Input | 100 μL |
Average Recovery | > 90% |
Time to Complete 10 Purifications | 20 minutes |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Component | Cat. 22700 (25 preps) | Cat. 52200 (10 preps) | Cat. 21900 (4 preps) |
---|---|---|---|
Buffer SK | 15 mL | 60 mL | 60 mL |
Wash Solution H | 18 mL | 18 mL | 18 mL |
Elution Buffer I | 6 mL | 12 mL | 12 mL |
Endotoxin Removal Solution | 1.5 mL | 1.5 mL | 1.5 mL |
Precipitation Solution | – | 1.5 mL | 1.5 mL |
Spin Columns (assembled with Collection Tubes) | – | 10 | 4 |
Spin Columns | 25 | – | – |
Collection Tubes | 25 | – | – |
Elution Tubes (1.7 mL) | 25 | – | – |
Elution Tubes (15 mL) | – | 10 | – |
Elution Tubes (50 mL) | – | – | 4 |
Product Insert | 1 | 1 | 1 |
SD-25/SD-25C Vacuum Centrifugal Concentrator
Ambient temperature type/Refrigerated type
Technical Parameter
Temperature range | Room Temperature~+80℃ | -10℃~+80℃ |
Temperature Accuracy | 士1℃ | |
Max.Speed | 2500rpm | |
Max.Capacity | 6x100ml | |
Timer | 0~99h59min | |
Vacuum control range | 0.1~1000mbar | |
Main unit withstands vacuum levels | 0.01mbar | |
Noise | ≤55dBA | ≤65dBA |
Voltage | 0.7kw | 1.3kw |
Power supply | 220v,50Hz | |
Dimension(L×W×Hmm) | 360*448*304mm | 440*653*420mm |
Adapter Rotor
Rotor Type | Rotor Volume | Rotor Type | Rotor Volume |
Angle Rotor | 42×1.5/2ml | Angle Rotor | 8×50ml |
Angle Rotor | 108×1.5/2ml | Angle Rotor | 6×100ml |
Angle Rotor | 48×5ml | Angle Rotor | 16*20ml Sample vial |
Angle Rotor | 30×10ml | Angle Rotor | 16*5ml+8*4ml+8*3ml |
Angle Rotor | 24×15ml | Microplate Rotor | 2×96well |
Key features:
1. High-definition LCD touch screen, simultaneously displaying operational parameters: speed, temperature, vacuum, and running time.
2. Delayed start: after reaching a fixed speed, Start the vacuum pump to effectively prevent sample mixing.
3. Fully automatic vacuum control system, vacuum setting range0.1~1000mbar, Control accuracy0.1mbar.
4. 1.5/2ml Rotor stacking for simultaneous use; rotor replacement without tools.
5. Programmable with temperature and pressure settings; capable of storing 36 programs
6. Compatible with various rotor heads; transparent glass window for easy observation.
7. Magnetic drive: maintenance-free, non-contact drive, fully sealed.
8. Safety in use: inductive electric self-suction door lock ensures the centrifugal concentrator can only start when the door cover is fully closed and locked.
9. Can be used in conjunction with freeze-drying systems
Model:
SD-25/SD-25C
Brand:
Yingtai