This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Specifications
Features | Specifications |
Main Functions | Isolation total DNA from tissue / blood / body fluid / swab /dry blood spots |
Applications | PCR, qPCR, southern bolt and virus detection, etc |
Purification method | Mini spin column |
Purification technology | Silica technology |
Process method | Manual (centrifugation or vacuum) |
Sample type | Tissue, cell, blood, saliva, swab, blood spot,semen and other clinical samples |
Sample amount | Solid tissue: 1-10mg; Anticoagulant blood: 200μl |
Elution volume | ≥20μl |
Time per run | 30 – 60 minutes |
Liquid carrying volume per column | 800µl |
Binding yield of column | 100µg |
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Contents | D301802 | D301803 |
Purification Times | 50 | 250 |
HiPure DNA Mini Columns I | 50 | 250 |
2ml Collection Tubes | 100 | 500 |
Buffer ATL | 30 ml | 150 ml |
Buffer AL | 30 ml | 150 ml |
Buffer GW1 | 22 ml | 88 ml |
Buffer GW2 | 12 ml | 50 ml |
Proteinase K | 24 mg | 120 mg |
Protease Dissolve Buffer | 1.8 ml | 10 ml |
Buffer AE | 15 ml | 60 ml |
Storage and Stability
Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
APN-C3-PEG4-alkyne is a heterobifunctional linker containing an APN moiety with exquisite chemoselectivity for cysteine and an alkyne group. The superior stability of APN-cysteine conjugates in aqueous media, human plasma, and living cells makes this new thiol-click reaction a promising methodology for applications in bioconjugation. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
APN-C3-PEG4-alkyne is a heterobifunctional linker containing an APN moiety with exquisite chemoselectivity for cysteine and an alkyne group. The superior stability of APN-cysteine conjugates in aqueous media, human plasma, and living cells makes this new thiol-click reaction a promising methodology for applications in bioconjugation. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map