The blood bag tube sealer is a compact equipment to seal the blood bags, infusion bags, urine bags by high frequency sealing system. It is widely used in blood bank, hospital, biological industry, etc.
Detail
Application
The blood bag tube sealer is a compact equipment to seal the blood bags, infusion bags, urine bags by high frequency sealing system. It is widely used in blood bank, hospital, biological industry, etc.
Features
No Hemolysis
With suction feet to avoid moving, can be used in blood collecting vehicle.
Technical Parameters
Model
HG-BTS1
Sealing time
2-4S
Sealing Type
Automatic
Diameter of tube
φ2-6mm(Tube thickness≤1.5mm)
Powe supply
220V 0.7A
Consumption
150W
External Size
310*190*150mm
Package Size
405*290*240mm
Net/Gross Weight
6/7kgs
Other Products
PACE® GENOTYPING ASSAY
Product Info
Document
Product Info
ABOUT
PACE (PCR Allelic Competitive Extension) genotyping chemistry is a homogeneous, PCR-based allele-specific technology for the analysis of DNA sequence variants, most commonly SNPs (Single Nucleotide Polymorphisms) and Indels (insertion / deletions).
PACE genotyping chemistry is comprised of two parts:
PACE Genotyping Assay: two allele-specific forward primers and one common, reverse primer. The allele-specific forward primers each have different 3′ terminal bases reflecting the target variant, and a unique 5’ tail sequence which is incorporated as part of the fluorescent signal mechanism.
PACE Genotyping Master Mix: containing all remaining components required for PCR and the generation of fluorescent signals. PACE Genotyping Master Mix contains a novel, universal, fluorescent reporting cassette to produce machine-readable fluorescent signals (FAM and HEX) corresponding to the assay genotypes.
When combined with sample DNA, these components create a PACE Genotyping Reaction, as illustrated in the figure below.
We have extensive knowledge and experience in assay design, especially when it comes to allele-specific PCR. PACE Genotyping Assays are available to purchase either Validated and Unvalidated. Validated assays require customer DNA to validate and optimise, for guaranteed performance. Unvalidated assays are designed in silico and supplied untested.
REQUIRED COMPONENTS
qPCR machine or Thermocycler + Fluorescent plate reader
PCR plate or equivalent and appropriate optically clear seal
Template DNA
PCR-grade water
PACE Genotyping Master Mix or PACE 2.0 Genotyping Master Mix
STEPS TO YOUR PACE GENOTYPING ASSAY DESIGN
Place your order on this page. Our support team will contact you by email.
Fill out an Assay Design Template form with all the information we need to process your custom PACE Genotyping Assay order. We will email you a copy of the template when we first contact you, or your can download a copy here.
Using the information you provide us, we will create your PACE Genotyping Assay designs, order the oligos, and send you design sequences.
Once we receive the oligos, we assemble the assay(s) and then ship an aliquot to you (unvalidated) or test on your DNA samples before shipping the aliquot to you (validated).
This product is suitable for rapid extraction of DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from blood, buffy coat, tissue and other samples
Applications
Second generation sequencing, PCR, real time PCR, etc.
Purification method
Polydisperse magnetic beads
Purification technology
Magnetic beads technology
Process method
Manual or automatic
Sample type
Anticoagulant blood, concentrated blood, buffy coat, lymphocytes and cultured cells
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and protease. DNA is released into the lysate. After adding magnetic particles and binding solution, DNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA was eluted by Elution Buffer.
Advantages
High purity – OD 260 / 280 : 1.7- 1.9, OD 260 / 230 : 1.5 – 2.0
Economy – less than 50% of the price of Qiagen and other imported products
High yield – most optimal process, ensuring the recovery up to 90%
Strong processing ability – samples including animal blood, cultured cells, animal tissues, etc.
Kit Contents
Contents
IVD3102
Purification Times
200
MagPure Particles
5 ml
Proteinase K
100 mg
Protease Dissolve Buffer
10 ml
Rnase A
40 mg
Buffer ATL
60 ml
Buffer AL
60 ml
Buffer BD*
20 ml
Buffer BW1*
110 ml
Elution Buffer
30 ml
Storage and Stability
Proteinase K, RNase A, MagPure Particles should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
This product is suitable for rapid extraction of DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money Rapid detection of all clinically relevant subtypes Positive copy number standard curve for quantification Highly specific detection profile High priming efficiency Broad dynamic detection range (>6 logs) Sensitive to < 100 copies of target
Accurate controls to confirm findings