1. Brushless motor, no pollution, free-maintenane.
2. Microprocessor control, LCD display which indicates the speed, time, RCF in operation, 10 kinds of brake setting , operate simply.
3. Electric lid lock, super speed, imbalance protection.
4. The centrifuge body is made of high quality steel, stainless steel chamber, safe and reliable.
5. Rotor is connected to spindle by specialized taper sleeve, loading simple and quick, no direction.
6. 3 tiers protection steel cover and get the ideal centrifuation result.
Detail
TGW16 Technical Parameter:
Max. Speed
16000rpm
Max. RCF
19040×g
Max. Capacity
10×5ml
Time Range
0~99min59s
RPM/RCF Convert
Yes
Noise (dB)
≤ 55
Acc/Dec
10 Kinds
Speed Accuracy
±20r/min
Voltage(V/Hz)
AC 220V/110V 50HZ/60HZ
Size (W x D x Hmm)
355×270×205mm
Net Weight(Kg)
16KG
Certificates
CE,ISO & Calibration report are available
Matched Rotors for TGW16
Order No
Rotor
Max speed (rpm)
Max Volume(ml)
Max RCF (g)
W16-1
Angle rotor
16000
40×0.2ml
19040
W16-2
Angle Rotor
16000
24×0.5ml
18480
W16-3
Angle Rotor
16000
12×1.5/2ml
17940
W16-4
Angle Rotor
16000
10x5ml
17880
W16-5
Angle Rotor
14000
20×1.5/2ml
15580
W16-6
Angle Rotor
14000
4x8PCR
12070
Other Products
HCM117 Cled Medium
Product Info
Document
Product Info
Introduction
Usages: For the total microbial count in urine.
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light. Storage period of 3 years.
[CD1021] SMOChem™ Deoxynucleotide (dNTP) Mix, 25 mM each (100 mM total), 500 µl x 6
Product Info
Document
Product Info
Description
The SMOChem™ Deoxynucleotide (dNTP) Mix is an aqueous solution that contains an equimolar solution of ultrapure dATP, dCTP, dGTP and dTTP, each at a concentration of 25 mM at pH 8.5. The dNTP Mix is designed for many different molecular biology applications that involved in DNA synthesis or labeling, such as PCR, real-time PCR, DNA sequencing, reverse transcription, primer extension, and etc. The dNTP Mix is free of exo-deoxyribonuclease and endo-deoxyribonuclease as well as ribonuclease activity. The dNTP Mix offers the possibility to reduce the number of pipetting steps and the risk of reaction set up errors.
Features
Ideal for PCR amplification and cDNA synthesis
Premixed solution
Nuclease and ribonuclease free
Applications
PCR amplification of DNA fragments
DNA fill-in reaction
DNA sequencing
Reverse transcription
One-step RT-PCR
Storage
-20°C for 36 months
Document
The SMOChem™ Deoxynucleotide (dNTP) Mix is an aqueous solution that contains an equimolar solution of ultrapure dATP, dCTP, dGTP and dTTP, each at a concentration of 25 mM at pH 8.5. The dNTP Mix is designed for many different molecular biology applications that involved in DNA synthesis or labeling, such as PCR, real-time PCR, DNA sequencing, reverse transcription, primer extension, and etc. The dNTP Mix is free of exo-deoxyribonuclease and endo-deoxyribonuclease as well as ribonuclease activity. The dNTP Mix offers the possibility to reduce the number of pipetting steps and the risk of reaction set up errors.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
50 & 150 reactions