Widely used in the field of blood bank, pharmaceutical factory and laboratory.
Detail
DL6MB large capacity refrigerated centrifuge
Features:
1. Widely used in the field of blood bank, pharmaceutical factory and laboratory.
2. Brushless frequency motor, in great torque, free maintenance, no powder pollution, quick in speed up and down.
3. Digital display which indicates the program, speed, time,RCF, temperature.
4. Micro computer control, there are 10 kinds of program and 10 kinds of acceleration and deceleration for your choice.
5. There are 6 kinds of rotors for your choice.
6. Electric lid lock, compact design, super speed and imbalance protection.
7. The centrifuge body is made of high-quality steel, safe and reliable.
DL6MB Technical Parameter:
Max. Speed
6000rpm
Max. RCF
6600*g
Max. Capacity
6×1000ml(6*500ml blood bag)
Time Range
0~9h59min
RPM/RCF Convert
Yes
Noise (dB)
≤ 55
Temperature
-20-40 degrees
Acc/Dcc
10 Kinds
Speed Accuracy
±20r/min
Temperature Accuracy
±1℃
Voltage(V/Hz)
AC 220V 50HZ/60HZ
Size (W x D x Hmm)
800×675×830mm
Net Weight(Kg)
310KG
Certificates
CE,ISO & Calibration report are available
Matched Rotors for DL6MB
Order No.
Rotor No.
Max Speed (rpm)
Max Volume(ml)
Max.RCF(×g)
No30298
Swing Rotor
4200
6×1000ml
5100
NO30221
Angle Rotor
6000
4×300ml
5390
NO30222
Angle Rotor
6000
6×300ml
5660
NO30223
Angle Rotor
6000
6×500ml
6600
Other Products
D3018 HiPure Universal DNA Kit
Product Info
Document
Product Info
Introduction
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from tissue / blood / body fluid / swab /dry blood spots
Applications
PCR, qPCR, southern bolt and virus detection, etc
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot,semen and other clinical samples
Sample amount
Solid tissue: 1-10mg; Anticoagulant blood: 200μl
Elution volume
≥20μl
Time per run
30 – 60 minutes
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Wide applicability- handle a variety of liquid samples
Kit Contents
Contents
D301802
D301803
Purification Times
50
250
HiPure DNA Mini Columns I
50
250
2ml Collection Tubes
100
500
Buffer ATL
30 ml
150 ml
Buffer AL
30 ml
150 ml
Buffer GW1
22 ml
88 ml
Buffer GW2
12 ml
50 ml
Proteinase K
24 mg
120 mg
Protease Dissolve Buffer
1.8 ml
10 ml
Buffer AE
15 ml
60 ml
Storage and Stability
Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
β-Glucan
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
510
Signal Response:
Increase
Limit of Detection:
1 g/100 g
Reaction Time (min):
~ 100 min
Application examples:
Yeast preparations and other materials
Method recognition:
Novel method
This product has been discontinued (see here), please use the recommended replacement product β-Glucan Assay Kit (Yeast and Mushroom) for all your yeast and mushroom β-Glucan testing needs.
Enzymatic Yeast Beta-Glucan test kit, an enzymatic procedure for the measurement and analysis of 1,3:1,6-β-glucan in yeast. Also measures 1,3-β-glucan.
All reagents stable for > 12 months after preparation
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Document
This product has been discontinued (see here), please use the recommended replacement product β-Glucan Assay Kit (Yeast and Mushroom) for all your yeast and mushroom β-Glucan testing needs.
The process of automatically removing seals from plates has become more popular due to the repetitive task of removing plate seals, which can potentially lead to cross contamination, repetitive motion injuries & plate/seal damage.
Application: Automatic & Manual MicroPlate Seal Removal
Suitable for use in the Automated Plate Seal Remover (formally XPeel)
Document
Overview
The process of automatically removing seals from plates has become more popular due to the repetitive task of removing plate seals, which can potentially lead to cross contamination, repetitive motion injuries & plate/seal damage.
Application: Automatic & Manual MicroPlate Seal Removal
Suitable for use in the Automated Plate Seal Remover (formally XPeel)