1.Widely used in the field of biochemistry、biological products、pharmaceutical factory and laboratory.
2. Brushless DC motor for model Cytoprep-1, free maintenance, no powder pollution, quick in speed up and down.
3. Smooth in operation, low noise and small vibration.
4. Frame is 3 tiers protection steel jacket, and with the stainless steel chamber, inside protective steel lagging which is simple-compact, light weight.
5. Microprocessor control, it can control rotate speed, and relative RCF, digital display which indicates the speed, time, RCF.
6. Automatically electric lid lock, super speed、over temperature protection and imbalance protection.
7. Power: AC 110V/220V, 50/60HZ, speed range:0-2800rpm, speed accuracy:± 20rpm
8. Emergency locks under the bottom of the centrifuge which help you open the lid when power off.
9. The centrifuge body is made of high-quality steel, safe and reliable.
Attogene’ s RNase Inhibitor is a protein-based ribonuclease inhibitor which noncovalently binds and inactivates a wide variety of RNases in a range of temperature (37–65°C) and pH (5.5–8.5) conditions. This product is distinct from placental RNase Inhibitor protein in that it inactivates RNases I and T1 in addition to RNases A, B and C. NA2021 is distinct from RNase Inhibitor protein in that it is less expensive, have more robust interactions with RNAses.
MADE AND FUNCTIONALLY TESTED AT ATTOGENE (MADE IN AUSTIN TEXAS – USA)
Document
RNase Inhibitor (10,000 units)
Concentration: 40 units/μL
Volume: 0.25 mL
Storage Conditions: Store at 2°C – 8°C
Inhibits: RNases A, B, and C
Supplied in: 1X PBS with 0.05% Sodium Azide.
Lyophilized format designed for room temperature shipping
Available in TaqMan format for analysis
Norgen’s EBV TaqMan PCR Lyophilized Kit is designed for the detection of EBV specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s EBV TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of EBV specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
All kit components should be stored at -20°C upon arrival.
Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Each kit is provided with 4 tubes of 2X PCR Master Mix and each tube is enough to run 25 reactions. It is not necessary to reconstitute all Master Mix tubes at once. The Master Mix tubes can be reconstituted as and when needed.
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
The 16S V1-V2 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V1-V2 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.
The 16S V1-V2 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V1-V2 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.
Storage Conditions and Product Stability Norgen’s 16S V1-V2 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components should remain stable for at least 1 year when stored at the specified storage conditions.