1. Widely used in the field of pharmaceutical factory and laboratory.
2. Brushless frequency motor, in great torque, free maintenance, no powder pollution, quick in speed up and down.
3. Digital display which indicates the program, speed, time,RCF, temperature.
4. Micro computer control, there are 10 kinds of program and 10 kinds of acceleration and deceleration for your choice.
5. Several rotors for your choice.
6. Electric lid lock, compact design, super speed and imbalance protection.
7. The centrifuge body is made of high-quality steel, safe and reliable.
GL10 Technical Parameter:
Max. Speed
10000rpm
Max. RCF
15730×g
Max. Capacity
6×1000ml
Time Range
1~9h59min
RPM/RCF Convert
Yes
Noise (dB)
≤ 65
Temperature
-20~40℃
Acc/Dec
10 Kinds
Speed Accuracy
±20r/min
Temperature Accuracy
±1℃
Voltage(V/Hz)
AC 380V/220V 50HZ/60HZ
Size (W x D x Hmm)
800×740×930mm
Net Weight(Kg)
360KG
Certificates
CE,ISO & Calibration report are available
Matched Rotors for GL10
Order No.
Rotor No.
Max Speed (rpm)
Max Volume(ml)
Max.RCF(×g)
G10-1
Angle Rotor
8000
6×1000ml
14550
G10-2
Angle Rotor
9000
6×500ml
14860
G10-3
Angle Rotor
10000
6×300ml
15730
G10-4
Swing Rotor
4200
6×1000ml
5100
Other Products
D3018 HiPure Universal DNA Kit
Product Info
Document
Product Info
Introduction
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from tissue / blood / body fluid / swab /dry blood spots
Applications
PCR, qPCR, southern bolt and virus detection, etc
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot,semen and other clinical samples
Sample amount
Solid tissue: 1-10mg; Anticoagulant blood: 200μl
Elution volume
≥20μl
Time per run
30 – 60 minutes
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Wide applicability- handle a variety of liquid samples
Kit Contents
Contents
D301802
D301803
Purification Times
50
250
HiPure DNA Mini Columns I
50
250
2ml Collection Tubes
100
500
Buffer ATL
30 ml
150 ml
Buffer AL
30 ml
150 ml
Buffer GW1
22 ml
88 ml
Buffer GW2
12 ml
50 ml
Proteinase K
24 mg
120 mg
Protease Dissolve Buffer
1.8 ml
10 ml
Buffer AE
15 ml
60 ml
Storage and Stability
Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
The HiPure Total RNA Kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA (not include miRNA) from animal tissues, cells and simple plant tissues using one column
Applications
RT-PCR, qRT-PCR, Northern hybridization, second generation sequencing
Cells: ≤1 x 107 Animal tissue: 1-20 mgPlant leaves: 50-150 mg Yeast cells: 5 x 106
Yield
2-100μg
Elution volume
≥50μl
Time per run
≤15 minutes(1-24 samples)
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
HiPure RNA technology simplifies total RNA isolation. Samples are first lysed and then homogenized. Ethanol is added to the lysate to provide ideal binding conditions. The lysate is then loaded onto the HiPure silica membrane and RNA binds to the silica membrane, and all contaminants are efficiently washed away. For certain RNA applications that are sensitive to very small amounts of DNA, the residual amounts of DNA remaining can be removed using a convenient on-column DNase treatment. Pure, concentrated RNA is eluted in water.
Advantages
Efficient removal of DNA – unique genomic DNA removal column without DNase treatment
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Fast – several samples can be extracted in 20 minutes by column method
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
Kit Contents
Contents
R401102
R401103
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
50
250
RTL Lysis Buffer
50 ml
200 ml
RNA Binding Buffer
15 ml
75 ml
Buffer RW1
50 ml
200 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
The HiPure Total RNA Kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provides a rapid method for the purification of total RNA from non-preserved saliva and nasal/throat swabs, and from preserved saliva collected on Norgen’s Saliva RNA Collection and Preservation Devices Dx (Cat. 53800) or preserved swabs collected in Norgen’s Total Nucleic Acid Preservative Tubes Dx (Cat. Dx69200). Purification is based on using Norgen’s proprietary resin separation matrix. RNA is preferentially purified from other cellular components such as proteins, without the use of phenol or chloroform. The chemistry employed in the kit allows the purification of total RNA, including viral and bacterial RNA, irrespective of size or GC content. The purified RNA is ideal for in vitro diagnostic use for medical purposes.
Saliva/Swab RNA Purification Kit Dx (Spin Column)
This kit is optimized to be used with any downstream application employing enzymatic amplification or other enzymatic modifications of RNA followed by signal detection or amplification. Any diagnostic results generated using the RNA isolated with Norgen’s Saliva / Swab RNA Purification Kit Dx in conjunction with an in vitro diagnostic assay should be interpreted with regard to other clinical or laboratory findings.
To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used.
Norgen’s Saliva/Swab RNA Purification Kit Dx is intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques.
Norgen’s Saliva/Swab RNA Purification Kit Dx does not provide a diagnostic result. It is the sole responsibility of the user to use and validate the kit in conjunction with a downstream in vitro diagnostic assay.
This kit is optimized to be used with any downstream application employing enzymatic amplification or other enzymatic modifications of RNA followed by signal detection or amplification. Any diagnostic results generated using the RNA isolated with Norgen’s Saliva / Swab RNA Purification 96-Well Kit Dx in conjunction with an in vitro diagnostic assay should be interpreted with regard to other clinical or laboratory findings. To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used. Norgen’s Saliva / Swab RNA Purification 96-Well Kit Dx is intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques. Norgen’s Saliva / Swab RNA Purification 96-Well Kit Dx does not provide a diagnostic result. It is the sole responsibility of the user to use and validate the kit in conjunction with a downstream in vitro diagnostic assay.
High throughput 96-well plate format for rapid purifications
Very consistent well-to-well RNA isolation
Bind & elute all RNA irrespective of size or GC content, without bias
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. All solutions and plastics can be used until the expiration date specified on their labels.