t-Boc-N-Amido-PEG8-propargyl has an alkyne group and Boc-protected amine. The alkyne group reacts with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The deprotection of Boc-protected amine can be peformed under mild acidic conditions. The hydrophilic PEG chain enhances the solubility of the molecule in aqueous solution. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
t-Boc-N-Amido-PEG8-propargyl has an alkyne group and Boc-protected amine. The alkyne group reacts with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The deprotection of Boc-protected amine can be peformed under mild acidic conditions. The hydrophilic PEG chain enhances the solubility of the molecule in aqueous solution. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
96-Well Low Elution Ring Magnetic Plate
Product Info
Document
Product Info
Designed for those labs wishing to separate magnetic beads into rings.
The Permagen ring magnet low elution plate was designed for use in automation applications where volumes as low as 5 µL are required. Most PCR plates are bent, leading to inconsistent lab results. Unlike most products, we have added an angled frame around the top of our plate, this helps with two things, straightening out the PCR plate, and leading it to the proper location on the magnets during automation
SBS SLAS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
Designed for those labs wishing to separate magnetic beads into rings.
The Permagen ring magnet low elution plate was designed for use in automation applications where volumes as low as 5 µL are required. Most PCR plates are bent, leading to inconsistent lab results. Unlike most products, we have added an angled frame around the top of our plate, this helps with two things, straightening out the PCR plate, and leading it to the proper location on the magnets during automation
Attogene’s Lead Rapid Lab Lateral Flow Kit can be used for the screening of Lead in water and food samples at greater than or equal to 10 ppb in a laboratory setting. Unlike the field-based kit, the lab kit is intended for a more technical end user who will be evaluating samples in a laboratory setting.
Lead contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Lead ion accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking Lead-contaminated food and water include brain, heart, kidney, lungs and immune system problems for adults, and the physical and mental development delays in infants and children. Attogene’s Lead Lateral Flow test gives results conforming of 10ppb or greater in 5-15 minutes.
This is a revolutionary product designed to make Lead testing in easy and affordable. This fast screening test kit contains 10 tests with everything needed for accurate results of unsafe lead levels. With reliable results in only 10 minutes, this test kit clearly gives results confirming Lead in water and conforming to the EPA guideline of 15 ppb (µg/L).
Sample Collection:
1. Take a first-draw sample
Immediately after opening a faucet or valve, collect a 250 mL sample. This sample should be from each tap used for consumption.
2. Take a flush sample
If first-draw sample results show elevated lead levels of 5 ppb or higher, collect a flush sample. To do this, ensure water has not been used for between 8 to 18 hours, then collect the sample at 30 seconds.
3. Take sequential samples
If you want to test a lead service line, collect 8 to 10 sequential samples, depending on how far the line is from the tap.
Standards and Regulations and recommendations for Lead
High Blood lead levels (i.e., greater than 700ppb) can cause serious health effects, including seizure, coma, and death. Blood levels as low as 100ppb have been associated with adverse effects on cognitive development, growth, and behavior among children aged 1-5 years.
Document
Screening of Lead in water samples at 5-10 ppb
Format: 10 tests (5 tests/5 controls)
Run Time: 15 Minutes