DBCO-PEG6-NHS ester is a click chemistry PEG reagent containing NHS ester that is able to react specifically and efficiently with primary amines (e.g. the side chain of lysine residues or aminosilane-coated surfaces) at neutral or slightly basic condition to form a covalent bond. The hydrophilic PEG spacer arm improves water solubility and provides a long and flexible connection that minimizes steric hindrance involved with ligation. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
DBCO-PEG6-NHS ester is a click chemistry PEG reagent containing NHS ester that is able to react specifically and efficiently with primary amines (e.g. the side chain of lysine residues or aminosilane-coated surfaces) at neutral or slightly basic condition to form a covalent bond. The hydrophilic PEG spacer arm improves water solubility and provides a long and flexible connection that minimizes steric hindrance involved with ligation. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
D2141 HiPure DNA Clean Up Kit
Product Info
Document
Product Info
Introduction
HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.
Details
Specifications
Features
Specifications
Main Functions
Recover DNA fragments between 20bp-20kbp from crude DNA and enzymatic reaction solution
Applications
PCR, sequencing, labeling reactions, ligations and restriction digestion, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Crude DNA, enzymatic reaction solution
Sample amount
<150μl
Recovery
80%
Elution volume
≥15μl
Time per run
≤10 minutes
Liquid carrying volume per column
800µl
Binding yield of column
20µg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gelslices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
High recovery efficiency – up to 80% DNA recovery
Fast – isolation can be completed in 10 minutes by column gel method
Low elution volume – elution volume can be as low as 10μl
Efficient – efficient removal of various inhibitory factors
Kit Contents
Contents
D214102
D214103
Purification Times
100 Preps
250 Preps
Buffer GWP
30 ml
60 ml
Buffer DW2
20 ml
50 ml
Elution Buffer
30 ml
60 ml
HiPure DNA Mini Columns I
50
250
2 ml Collection Tubes
50
250
Storage and Stability
HiPure DNA Clean Up Kit components are guaranteed for at least one year when stored at room temperature. If any precipitates form in the buffers, warm at 37℃ to dissolve.
Document
HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
L-Arabinose, D-Galactose
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
4 to 80 μg of L-arabinose or D-galactose per assay
Limit of Detection:
0.58 mg/L (L-arabinose), 0.69 mg/L (D-galactose)
Reaction Time (min):
~ 12 min (L-arabinose), ~ 6 min (D-galactose)
Application examples:
Analysis of hydrolysates of oligo- and polysaccharides (e.g. arabinan, arabinoxylan, galactan, arabinogalactan), milk, dairy products, foods containing milk (e.g. dietetic foods, bakery products, baby food, chocolate, sweets and ice-cream), food additives (e.g. sweeteners), cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Novel method
The L-Arabinose/D-Galactose test kit is a simple, reliable and accurate UV method for the measurement and analysis of L-arabinose and/or D-galactose in various materials including foods, feeds, beverages and plant products.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.
Very rapid reaction due to inclusion of galactose mutarotase (patented technology)
Very cost effective
All reagents stable for > 2 years after preparation
Only enzymatic kit available
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The L-Arabinose/D-Galactose test kit is a simple, reliable and accurate UV method for the measurement and analysis of L-arabinose and/or D-galactose in various materials including foods, feeds, beverages and plant products.
Q-PAGE™ Bis-Tris Precast Gel is a high-performance and easy to use precast polyacrylamide gel for electrophoresis in Bis-Tris buffer system (MOPS or MES). The optimized gel formula allows Q-PAGE™ Bis-Tris Precast Gel to show improved resolution, accurate results, and an extended shelf-life over conventional Laemmli Tris-HCl gels.
Q-PAGE™ Bis-Tris Precast Gels are available in gradient (4 to 12%) and fixed (8% and 12%) concentrations of polyacrylamide in 12-and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP2XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP3XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Key Features
User-friendly gel cassette:
Numbered and framed wells for sample loading
Labeled warning sign and green tape as reminder
Enhanced gel performance:
Enhanced band sharpness
Better resolution of small proteins
Stable for shipping at ambient temperature
Easy compatibility:
Available as homogeneous and adjusted gradient gels for a wide range of protein separation.
Compatible with most popular protein electrophoresis systems
Storage and stability
Store Q-PAGE™ Precast Gels at 4°C for periods up to 12 months.
Do not freeze Q-PAGE™ Precast Gels. Remove tape and comb before electrophoresis.
Keep Q-PAGE™ Precast Gels flat during storage.
Document
Q-PAGE™ Bis-Tris Precast Gel is a high-performance and easy to use precast polyacrylamide gel for electrophoresis in Bis-Tris buffer system (MOPS or MES). The optimized gel formula allows Q-PAGE™ Bis-Tris Precast Gel to show improved resolution, accurate results, and an extended shelf-life over conventional Laemmli Tris-HCl gels.
Q-PAGE™ Bis-Tris Precast Gels are available in gradient (4 to 12%) and fixed (8% and 12%) concentrations of polyacrylamide in 12-and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP2XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP3XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.