DBCO-PEG5-DBCO is a bifunctional click chemistry reagent. DBCO will react with azide-bearing compounds or biomolecules to form a stable triazole linkage without copper catalyst. The hydrophilic PEG spacer arm can increase water solubility and membrane permability. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
DBCO-PEG5-DBCO is a bifunctional click chemistry reagent. DBCO will react with azide-bearing compounds or biomolecules to form a stable triazole linkage without copper catalyst. The hydrophilic PEG spacer arm can increase water solubility and membrane permability. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
Enzymatic Yeast β-Glucan Assay Kit
Product Info
Document
Product Info
K-EBHLG
SKU: 700004278
50 assays per kit
Content:
50 assays per kit
Shipping Temperature:
Ambient
Storage Temperature:
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
β-Glucan
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
510
Signal Response:
Increase
Limit of Detection:
1 g/100 g
Reaction Time (min):
~ 100 min
Application examples:
Yeast preparations and other materials
Method recognition:
Novel method
This product has been discontinued (see here), please use the recommended replacement product β-Glucan Assay Kit (Yeast and Mushroom) for all your yeast and mushroom β-Glucan testing needs.
Enzymatic Yeast Beta-Glucan test kit, an enzymatic procedure for the measurement and analysis of 1,3:1,6-β-glucan in yeast. Also measures 1,3-β-glucan.
All reagents stable for > 12 months after preparation
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Document
This product has been discontinued (see here), please use the recommended replacement product β-Glucan Assay Kit (Yeast and Mushroom) for all your yeast and mushroom β-Glucan testing needs.
NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms)
Product Info
Document
Product Info
The NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality NGS libraries with low input DNA amount from 1 ng to 400 ng. The kit allows scientist to study samples with limited DNA such as tumor samples, patient samples, and other specially collected samples (FACS sorting etc.). The kit has high library conversion efficiency with as little as 1 ng DNA input. The fast and simple 1.5-hour protocol makes libraries with even coverage and low GC-bias based our unique chemistry for DNA end-polishing and ligation.
The kit needs double strand DNA fragments (blunt and/or sticky) as input DNA for NGS library preparation, and is compatible with DNA fragments generated from both enzymatic approach (for example, BioDynami DNA fragmentation enzymes, Cat.# 40061 and Cat.# 40062) and mechanical approaches such as sonication and nebulization etc.
NGS Low Input DNA Library Prep Kit Workflow
Three index types are available for the NGS Low Input DNA Library Prep Kit of illumina platform:
Non-index (Cat.# 30022): Libraries do not have index.
Index (Cat.# 30024): Each of our index primers contains a unique barcode sequence with 6 bases that can be used to identify the low input DNA libraries. Library multiplexing up to 48 samples is possible. Index information can be downloaded here.
Unique dual index (Cat.# 30025): Library multiplexing up to 96 low input DNA libraries is possible with unique dual indexes with our Four-Base Difference Index System. The system allows us to make indexes for the libraries that have at least 4 bases different from each other in the 8-base barcode length. Our unique dual index primers can reduce sequencing errors such as de-multiplexing errors, amplification errors, mis-assignment of reads, index cross-contamination, and also index hopping. The kit includes 96 pre-mixed unique pairs of index primers. Index information can be downloaded here.
Indexes are available for the MGI platform kits (Cat.# 34024).
Kit advantages:
Fast protocol
The hands-on time is only 10 minutes
The total protocol time is around 1.5 hours
Simple procedure
Ready-to-use master mix makes it simple for reaction setup
Less reaction components
Less magnetic beads required for cleanup steps: Save the cost more than 50%
Low input DNA amount: Starts from 1 ng of DNA
Comparison of library conversion efficiency under the same NGS library preparation condition. Input DNA amounts are 1 ng and 10 ng, respectively. DNA was mechanical sheared with Covaris before library prep. BioDynami kit: NGS Low Input DNA Library Prep Kit (Cat. #30022).
Comparison of library yield under the same NGS library prep condition. Input DNA amounts are 1 ng, 10 ng, and 100 ng. DNA was mechanical sheared with Covaris before library prep. BioDynami kit (Cat. #30022). PCR cycle numbers were indicated.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Fructan
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
4 to 80 µg of D-glucose, D-fructose or sucrose per assay
Limit of Detection:
1 g/100 g
Total Assay Time:
~ 30 min
Application examples:
Flours, plant materials (e.g. onion), food products and other materials
The Fructan HK test kit is suitable for the specific measurement and analysis of all fructo-oligosaccharides (reducing and non-reducing) and of fructan polysaccharides but is not suitable for the analysis of samples containing high levels of D-glucose, D-fructose, sucrose or maltose.
All reagents stable for > 12 months after preparation
Fructan kits are available only from Megazyme
Simple format
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Document
The Fructan HK test kit is suitable for the specific measurement and analysis of all fructo-oligosaccharides (reducing and non-reducing) and of fructan polysaccharides but is not suitable for the analysis of samples containing high levels of D-glucose, D-fructose, sucrose or maltose.