N-(Aminooxy-PEG2)-N-bis(PEG3-propargyl) consists of two terminal propargyl groups and an aminooxy group. The propargyl groups reacts with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The aminooxy group is reactive towards aldehydes to form oxime bonds. If a reductant is used, it will form a hydroxylamine linkage. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries. Aminooxy compounds are very reactive and sensitive; they cannot be stored for long term. Immediate use (within 1 week) is highly recommended.
Detail
N-(Aminooxy-PEG2)-N-bis(PEG3-propargyl) consists of two terminal propargyl groups and an aminooxy group. The propargyl groups reacts with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The aminooxy group is reactive towards aldehydes to form oxime bonds. If a reductant is used, it will form a hydroxylamine linkage. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries. Aminooxy compounds are very reactive and sensitive; they cannot be stored for long term. Immediate use (within 1 week) is highly recommended.
Other Products
C13131 HiPure gDNA Plate
Product Info
Document
Product Info
Introduction
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Details
Specifications
Features
Specifications
Recommended application
gDNA and RNA Isolation
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/B, 2 layers
Membrane aperture
1.0μm
Maximum binding yield of plasmid
30 μg
Maximum yield of alcohol mediated Binding
100 μg
Single liquid carrying capacity of column
900 μl
Minimum elution volume
80 μl
Withstand centrifugal force
4,000-5,000 x g
Centrifuge
Low speed centrifuge, Swing out Rotor, can placed a height of 6.5cm square, (height of HiPure DNA Plate & 1.6ml Collection Plate: height, 6.2cm)
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No.
Product Name
Package
C13131
HiPure gDNA Plate (2 x GF/B)with 1.6ml Collection Plate
10/Bag
Purchase Guide
Item No.
Product Name
Membrane type/number of layers
Collection tubes
Plasmid DNA binding capacity (Physical adsorption)
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Document
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
This kit is suitable for extracting total pathogen nucleic acid from a variety of clinical samples such as blood, serum, plasma, swab soaking solution, fluid accumulation and homogenate solution. This kit is designed to remove host cells background nucleic acid and enrich pathogen nucleic acid (including viral/bacterial/fungal DNA/RNA) from the sample. Purified DNA/RNA is ready for downstream applications such as PCR, virus detection, tNGS and other related experiments.
Details
Specifications
Features
Specifications
Main Functions
Extract Pathogen RNA/DNA from 0.5-1.5ml whole blood, plasma, serum, body fluid, homogenate suspension, culture solution, cell suspension, soaking solution or concentrate pathogen solution for tNGS application, remove host background nucleic acid.
Applications
Real Time PCR, biochip analysis, NGS
Products
Pathogen DNA / RNA
Purification method
Polydisperse magnetic beads
Purification technology
Magnetic beads technology
Process method
Manual or automatic
Sample type
whole blood, plasma, serum, body fluid, homogenate suspension, culture solution, cell suspension, soaking solution or concentrate pathogen solution
Sample amount
0.5 – 1.5 ml
Adaptive instrument
Nucleic acid extractor, pipetting workstation
Principle
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Protease. After adding magnetic particles and binding solution, DNA/RNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA/RNA was eluted by Buffer NFW.
Kit Contents
Contents
R667200C
R667202C
Purification Times
24 Preps
96 Preps
2ml Bead Tube (0.4g)
24
96
DNase I (Powder)
10 mg
15 mg
DNase Buffer
5 ml
20 ml
Protease Dissolve Buffer
3 ml
8 ml
Lysis Buffer LBX1
40 ml
180 ml
Buffer TL
5 ml
20 ml
Proteinase K
24 mg
120 mg
MagBind Particles N9
1.2 ml
5 ml
Buffer MLB
30 ml
120 ml
Buffer MW1*
13 ml
110 ml
Buffer MW2*
10 ml
50 ml
Buffer AVE
10 ml
20 ml
Storage and Stability
Proteinase K, DNase I powder and MagPure Particles N9 should be stored at 2–8°C upon arrival. However, short-term storage (up to 8 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This kit is suitable for extracting total pathogen nucleic acid from a variety of clinical samples such as blood, serum, plasma, swab soaking solution, fluid accumulation and homogenate solution. This kit is designed to remove host cells background nucleic acid and enrich pathogen nucleic acid (including viral/bacterial/fungal DNA/RNA) from the sample. Purified DNA/RNA is ready for downstream applications such as PCR, virus detection, tNGS and other related experiments.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Mannitol
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
5 to 75 μg of D-mannitol per assay
Limit of Detection:
0.50 mg/L
Reaction Time (min):
~ 4 min
Application examples:
Wine, chewing gum, dietetic foods, candies, cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Novel method
The D-Mannitol test kit is suitable for the rapid and specific measurement and analysis of D-mannitol in food, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).