The Legionella sp. TaqMan PCR Kit Dx is shipped on dry ice. The components of the kit should be frozen upon arrival. If one or more of the components is not frozen when the kit is received, or if any of the components have been compromised during shipment, please contact Norgen Biotek for assistance. All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 3 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. DxTM64400 (24 rxns)
MDx TaqMan 2X PCR Master Mix
550 μL
Legionella sp. Primer & Probe Mix Dx
2 x 70 μL
Legionella sp. Positive Control Dx – 200,000 copies/μL
50 μL
Nuclease-Free Water
2 x 1.25 mL
Product Insert
1
Other Products
PreviousNext[DM3260] FluoroBand™ 1 KB Plus (0.1-10 kb) Fluorescent DNA Ladder, 500 μlPreviousNext
Product Info
Document
Product Info
Description
The DM3260 FluoroBand™ 1 KB Plus (0.1-10 kb) Fluorescent DNA Ladder is a ready-to-use DNA ladder, which is pre-mixed with high sensitivity DNA binding fluorescent dye and loading dye for direct gel loading. The DNA Ladder DM3260 is composed of 19 individual DNA fragments: 10k, 8k, 6k, 5k, 4k, 3k, 2.5k, 2k, 1.5k, 1k, 900, 800, 700, 600, 500, 400, 300, 200, and 100 base pairs derived from a mixture of PCR products and specifically digested plasmid DNA; these bands can be visualized when illuminated with 470 nm blue light or UV light. This product contains three enhanced bands (3 kb, 1.5 kb and 500 bp) for easier reference. In addition, three tracking dyes, Xylene cyanol FF, Bromophenol blue and Orange G which mimic the migration of 4,000 bp, 500 bp and 50 bp dsDNA during electrophoresis are also added for real time monitoring. Real time observation of the electrophoresis is also possible if compatible light source is fitted to the electrophoresis tank.
Features
Sharp bands
Quick reference— enhanced bands
Ready-to-use— premixed with loading dye for direct loading
Stable— room temperature storage over 6 months
Directly observed by UV or blue light— premixed with high sensitive DNA fluorescent dye
Source
Phenol extracted PCR products and dsDNA digested with specific restriction enzymes, equilibrated in 10 mM Tris-HCl (pH 8.0) and 10 mM EDTA.
Range
100 ~ 10,000 bp
Concentration
87 µg/ 500 µl
Recommended loading volume
5 µl/ well
Storage
Protected from light Room temperature for 6 months 4°C for 12 months -20°C for 24 months
Document
The DM3260 FluoroBand™ 1 KB Plus (0.1-10 kb) Fluorescent DNA Ladder is a ready-to-use DNA ladder, which is pre-mixed with high sensitivity DNA binding fluorescent dye and loading dye for direct gel loading. The DNA Ladder DM3260 is composed of 19 individual DNA fragments: 10k, 8k, 6k, 5k, 4k, 3k, 2.5k, 2k, 1.5k, 1k, 900, 800, 700, 600, 500, 400, 300, 200, and 100 base pairs derived from a mixture of PCR products and specifically digested plasmid DNA; these bands can be visualized when illuminated with 470 nm blue light or UV light. This product contains three enhanced bands (3 kb, 1.5 kb and 500 bp) for easier reference. In addition, three tracking dyes, Xylene cyanol FF, Bromophenol blue and Orange G which mimic the migration of 4,000 bp, 500 bp and 50 bp dsDNA during electrophoresis are also added for real time monitoring. Real time observation of the electrophoresis is also possible if compatible light source is fitted to the electrophoresis tank.
Compact and stylish designed, the BioShake iQ high-end thermoshaker lets you perform all your standard mixing runs with a minimum of adjustments. The BioShake iQ offers outstanding performance to handle a wide range of applications across biotechnology, pharmaceutical and academic research.
Small. Light. Efficient. Quiet.
For microplates, tubes and glass vials
Fast & high-precision heating
Temperature range: ambient to 99°C
Precise mixing from 200 – 3,000 rpm
Wide range of thermo adapters
Stylish aluminium housing
ADVANCED TECHNOLOGY
Save time.
By combining the mixing operation with the incubation phase, reaction process times and operator workload are reduced and efficiency of many procedures is increased, resulting in a higher throughput.
The first-class finished aluminium housing gives the BioShake iQ its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
GENTLE MIXING OF SAMPLES
By planar orbital motion
German designed and manufactured, BioShake iQ thermoshaker offer an ultra-efficient, 2-dimensional shaking axis so that samples mix completely in a fraction of the time of competing systems.
The mixing orbit of 2.0 mm is always constant. The orbital shaking is precisely controlled, in fact, that you need never spin down your plates after mixing. Even tubes, vials, high density plates, or low sample volumes, offer no obstacle for these precision tools.
Fully adjustable between 200 rpm and 3,000 rpm, well beyond the speeds of most other brands, guarantees fast, splatter-free, mixing for tubes, glass vials or across an entire 384-well microplate.
HOMOGENEOUS HEATING
Using large-area heating source in combination with digital sensor electronic
The BioShake iQ heats from ambient to 99°C in a short time, provides ease of use features, amazing comfort and maximum safety.
Within the BioShake iQ thinnest large-area heating elements and sensors are integrated. During the heat up time the special electronic control system guarantees the same temperature for all vessels with minimal deviations. Temperatures are selectable from ambient temperature to 99°C in steps of 1.0°C. The nominal regulation accuracy is better than ±0.1°C with a uniformity of temperature distribution better than ±0.5°C at 45°C across the heating surface.
Exchangeable thermo adapter plates and thermal blocks enable a perfect adaptation to microplates, tubes or glass vials.
UNIVERSAL SPRING CLAMPS
Suitable for all microplates
In the corners eight spring clamps are inserted for easy fixation of skirted microplates anddeep well plates in SBS format 127.7 x 85.5 mm without an attached adapter. These spring clamps lock the microplate quickly and safely, even at the highest mixing frequencies.
For flexible and deformable PCR plates we recommend using of the related PCR adapter.
Fast mixing processes with frequent plate changes can be performed in the routine as easy and safe.
COMFORT
Simple intuitive operation and programming
The BioShake iQ is operated from the front face of the enclosure which includes touch buttons and a display.
Special buttons for start, stop and storage of time and mixing modes enable the instrument to run complex applications. This opens new points of view on the daily laboratory work and optimizes routine application enormously.
The short mix button allows short and fast mixing in between.
The two line LCD display guarantees simultaneous and safe reading of all programmed and measured parameters as time, mixing frequency and temperature.
EXCHANGABLE THERMO ADAPTERS
For a wide range of applications
The BioShake iQ comes with a variety of standardized and specific adapter plates. The replacement of the adapters are very simple.
Perfect shaped adapters allow an optimal fit for standard tubes, lysis tubes, microplates, glass vials and other sample vessels. An excellent temperature uniformity and homogeneity is guaranteed for all samples.
UNIQUE DESIGN MEETS HIGH-END TECHNOLOGY
First-class finished aluminium housing
Unique and efficient design combined with the most compact housing result in beautiful and well-defined laboratory equipment. Therefore, the first-class finished aluminium housing gives the BioShake iQ its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
Safety of the user and ease of use are clearly a priority.
MADE IN GERMANY
High-end instruments for daily routine
A perfectly harmonious blend of high-tech and handmade. “Made in Germany” has always been a recipe for success for QInstruments. 100% of QInstruments production takes place in Germany.
The focus is on human diligence and on being environmentally friendly. The company upholds its quality guarantee by means of consistent quality management. For more than 15 years these lab automation professionals from Jena have used only high-quality materials to ensure sustainable production, applied innovative thinking and undertaken research in a future-oriented way – all as a matter of course.
Document
For microplates, tubes and glass vials
Fast & high-precision heating
Temperature range: ambient to 99°C
Precise mixing from 200 – 3,000 rpm
Wide range of thermo adapters
Stylish aluminium housing
The series of DNA Size Selection Kits (Magnetic Beads) were developed for DNA size selection using magnetic beads. A total of 11 kits are available, with different selection ranges spanning from 50 bp to over 10 kb. The kits provide a simple and quick approach for the enrichment of a specific range of DNA fragments. The kit workflow allows double-sided or single-sided size selection for specific size cutoffs.
Gel images of different ranges of size selection. Sheared human genomic DNA was used as input.
.
DNA size selection is a selective capture of DNA fragments of a specific range of size for next-generation sequencing (NGS) library preparations, PCR, ChIP assay, DNA ligations, endonuclease digestions, adapter removal, and other genomics and molecular biology applications. DNA size selection is preferred after NGS library prep in most of the cases. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads technology uses paramagnetic particles, also known as SPRI (Solid Phase Reversible Immobilization) beads, to bind DNA reversibly and selectively. DNA fragments can be size-selected and purified by changing the properties of the magnetic beads or SPRI beads. The magnetic beads can easily separate the beads-binding DNA from the contaminants and unwanted components in the samples. The samples after DNA size selection are free of contaminants such as buffer components, enzymes, proteins, salts, dNTPs, primers, and adapters. Our proprietary magnetic beads reagents improve yield, selectivity, and reproducibility.
Specific DNA fragments at a certain length range can be purified simply using magnetic separation with different beads components, avoiding tedious and time-consuming gel extraction and column-based purification. The magnetic beads method is popular for common DNA size selection, including library size selection. The first beads-binding step, referred to as the right-side clean-up, removes large DNA fragments. The large DNA fragments are bound to the beads and are discarded. The desired DNA fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-binding, referred to as the left-side clean-up. The double-size selected DNA fragments are eluted after ethanol rinsing.
DNA size selection with dual clean-ups.
.
A single clean-up is needed for DNA size selection with large fragments. In this case, only the large DNA fragments are bound to the beads. The selected larger DNA fragments are eluted after ethanol rinsing.
DNA size selection with single clean-up for >5 kb and >10 kb DNA.
.
Features of DNA size selection and library size selection
High specificity and high recovery of size selection
11 selection ranges are available, including 5 ranges for NGS library size selection
50-100 bp
100-200 bp
200-500 bp
250-350 bp: ideal for illumina PE100 sequencing
300-450 bp: ideal for illumina PE150 sequencing
450-750 bp: ideal for illumina PE300 sequencing
500-1000 bp
1-3 kb
1-5 kb
>5 kb: ideal for long-read sequencing
>10 kb: ideal for long-read sequencing
Fast and simple
20-min protocol
No gel purification required
No columns required
No centrifugation required
Efficient removal of contaminants and unwanted components