No need for staining and destaining of denaturing gels since Norgen’s loading buffer contains ethidium bromide
Highly stable
Nine bands from 200 bases to 4000 bases
Convenient lyophilized format provides better product stability
The Norgen 1 kb RNA Ladder is a set of RNA transcripts derived from recombinant DNA templates. This ladder is suitable for precise sizing of a wide range of RNA molecules using native or denaturing agarose gels, and can be visualized under UV.
Instructions: To reconstitute the lyophilized RNA ladder, add 250 µL of 1x loading buffer to each 25 loads vial and vortex gently. Heat at 80°C for 10 minutes. Incubate on ice for 1 min. Load 10 µL on a 1-2% gel. For optimal results, use Norgen 2x loading buffer with each RNA sample. No need for staining and destaining of denaturing gels since Norgen’s loading buffer contains ethidium bromide.
Store at -20°C.
Documentation
Other Products
High-speed lab mixer for microplates & tubes
Product Info
Document
Product Info
Compact and stylish designed, the BioShake XP high-speed microplate mixer lets you perform all your standard mixing runs with a minimum of adjustments. The XP offers outstanding performance to handle a wide range of applications across biotechnology, pharmaceutical and academic research.
Small. Light. Efficient. Quiet.
Ideal for microplates & PCR plates
High-precision mixing from 200 up to 3,000 rpm
Universal spring clamps for easy fixation
Wide range of adapters
Stylish, fire resistant aluminium housing
ADVANCED TECHNOLOGY
Compact & stylish designed
Mixing tasks in microplates can be realized fast & safe with using adjustable speed of 200 up to 3,000 rpm.
The BioShake mixing-technology is obviously more robust, vibration free and needs less maintenance compared to classical mixers.
The first-class finished aluminium housing gives the BioShake XP its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
GENTLE MIXING OF SAMPLES
By planar orbital motion
German designed and manufactured, BioShake XP plate mixer offer an ultra-efficient, 2-dimensional shaking axis so that samples mix completely in a fraction of the time of competing systems.
The mixing orbit of 2.0 mm is always constant. The orbital shaking is precisely controlled, in fact, that you need never spin down your plates after mixing. Even tubes, vials, high density plates, or low sample volumes, offer no obstacle for these precision tools.
Fully adjustable between 200 rpm and 3,000 rpm, well beyond the speeds of most other brands, guarantees fast, splatter-free, mixing for tubes, glass vials or across an entire 384-well microplate.
COMFORT
Simple intuitive operation and programming
The BioShake XP is operated from the front face of the enclosure which includes touch buttons and a display.
Special buttons for start, stop and storage of time and mixing modes enable the instrument to run complex applications. This opens new points of view on the daily laboratory work and optimizes routine application enormously.
The short mix button allows short and fast mixing in between.
The two line LCD display guarantees simultaneous and safe reading of all programmed and measured parameters as time and mixing frequency.
UNIVERSAL SPRING CLAMPS
Suitable for all microplates
In the corners eight spring clamps are inserted for easy fixation of skirted microplates anddeep well plates in SBS format 127.7 x 85.5 mm without an attached adapter. These spring clamps lock the microplate quickly and safely, even at the highest mixing frequencies.
For flexible and deformable PCR plates we recommend using of the related PCR adapter.
Fast mixing processes with frequent plate changes can be performed in the routine as easy and safe.
UNIQUE DESIGN MEETS HIGH-END TECHNOLOGY
First-class finished aluminium housing
Unique and efficient design combined with the most compact housing result in beautiful and well-defined laboratory equipment. Therefore, the first-class finished aluminium housing gives the BioShake XP its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
Safety of the user and ease of use are clearly a priority for us.
EXCHANGABLE ADAPTERS
For a wide range of applications
The BioShake XP comes with a variety of standardized and specific adapter plates. The replacement of the adapters are very simple.
Perfect shaped adapters allow an optimal fit for standard tubes, lysis tubes, microplates, glass vials and other sample vessels.
MADE IN GERMANY
High-end instruments for daily routine
A perfectly harmonious blend of high-tech and handmade. “Made in Germany” has always been a recipe for success for QInstruments. 100% of QInstruments production takes place in Germany.
The focus is on human diligence and on being environmentally friendly. The company upholds its quality guarantee by means of consistent quality management. For more than 15 years these lab automation professionals from Jena have used only high-quality materials to ensure sustainable production, applied innovative thinking and undertaken research in a future-oriented way – all as a matter of course.
Document
Ideal for microplates & PCR plates
High-precision mixing from 200 up to 3,000 rpm
Universal spring clamps for easy fixation
Wide range of adapters
Stylish, fire resistant aluminium housing
DBCO-NHCO-PEG4-NHS ester is a PEG linker containing NHS ester that is able to react specifically and efficiently with primary amines such as the side chain of lysine residues or aminosilane-coated surfaces at neutral or slightly basic condition to form a covalent bond. The hydrophilic PEG spacer arm improves water solubility and can also provide a long and flexible connection that minimizes steric hindrance during ligation. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
DBCO-NHCO-PEG4-NHS ester is a PEG linker containing NHS ester that is able to react specifically and efficiently with primary amines such as the side chain of lysine residues or aminosilane-coated surfaces at neutral or slightly basic condition to form a covalent bond. The hydrophilic PEG spacer arm improves water solubility and can also provide a long and flexible connection that minimizes steric hindrance during ligation. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
HiDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and therefor, is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) that is also termed allele-specific amplification (ASA).HiDi® 2x PCR Master Mix – ready to use mix simplifies your PCR setup. Only target-specific primers and template need to be added as the mix contains all components for a successful and reliable PCR. This ensures reproducible results, significantly reduces set-up times and the risk of pipetting errors.This PCR mix is also available with a full-length Taq DNA polymerase with a nuclease domain, featuring 100% compatibility with hydrolysis probes (TaqMan® probes etc.).Benchmarking with products of competitors conducted by us and others show that the HiDi® DNA polymerase family is the first choice for highly selective PCRs, such as genotyping by allele-specific PCR, HLA genotyping, analysis of single CpG methylation sites or the detection of mutations in a high background of wild-type sequences. By using HiDi® DNA polymerase, less than 10 copies of a mutation can be detected in a background of >10.000 wild-type copies straight away without any other tedious assay optimization.It has also been shown that HiDi® DNA polymerase family is highly suitable for quality control in CRISPR-Cas or TALEN-based applications.Several independently conducted studies show that HiDi® DNA polymerase is ideally suited for use in asPCR in numerous research areas ranging from mutation detection to genome editing. (read more)For research use and further manufacturing.In case you are aiming to use our RUO products as components or for your development of e.g. an IVD medical device, please contact us.
Casestudies: HiDi® DNA Polymerase: Applications from mutation detection to genome editing (read more)
Example Primer Design
Matching vs. mismatching nucleotide is placed at the 3′-end of the primer for best discrimination results.
Example Results – There´s no accounting for taste
Cilantro: some people love it in their food, some hate it. Here we are detecting a genomic SNP (rs72921001) in HeLa genomic DNA. This SNP is reported to be close to a number of genes coding for olfactory receptors. (Reference: Eriksson N. et al. (2012), “A genetic variant near olfactory receptor genes influences cilantro preference.”)
Considering, that only the C-allele specific primer is extended and yielding in a specific amplicon, we can conclude a genetic predisposition in disliking cilantro, as this SNP is significantly associated with detecting a soapy taste to cilantro.
Allele-specific PCRs were performed from 1 ng/µl of HeLa gDNA in the presence of a realtime dye, indicating the amplification of the C-allele specific primer only. The A-allele specific primer is discriminated, thus not amplified up to 50 cycles.
PCR products were subsequently analysed on a 2.5% agarose gel. Specific product is visualized by ethidium bromide staining at the amplicon length of 109 bp.
Document
HiDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and therefor, is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) that is also termed allele-specific amplification (ASA).
HiDi® 2x PCR Master Mix – ready to use mix simplifies your PCR setup. Only target-specific primers and template need to be added as the mix contains all components for a successful and reliable PCR. This ensures reproducible results, significantly reduces set-up times and the risk of pipetting errors.