Staphylococcus aureus TaqMan PCR Detection Kits

Facebook
X
Pinterest
Email

Detail

Overview

  • Detection kits for Staphylococcus aureus
  • Available in TaqMan format for analysis

Mastitis is the single most costly disease of dairy cattle resulting in the reduction of milk yield and quality. The inflammation of the utter is mainly caused by bacteria, and Staphylococcus aureus is often considered the most common cause of contagious mastitis in dairy herds. S. aureus infection is estimated to be present in up to 90% of dairy farms and is responsible for 35% of the economic loss in the dairy industry (Lee et al., 2005). S. aureus is a facultatively anaerobic, Gram positive bacterium. The majority of S. aureus strains are catalase-positive and coagulasepositive, which forms the basis of traditional identification methodology.

Staphylococcus aureus TaqMan PCR Kit, 100 reactions

  • Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
  • Specific Primer and Probe mix for the pathogen/virus/viroid of interest
  • Primer and Probe mix
  • Positive and negative control to confirm the integrity of the kit reagents

Staphylococcus aureus TaqMan PCR Probe/Primer Set and Controls, 100 reactions

  • Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
  • Nuclease-free water
  • Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix

For research use only and NOT intended for in vitro diagnostics.

Details

Supporting Data

Figure 1 / 3

Previous

Staphylococcus aureus TaqMan PCR Kit Figure 1
Staphylococcus aureus TaqMan PCR Kit Figure 1
Staphylococcus aureus TaqMan PCR Kit Figure 2
Staphylococcus aureus TaqMan PCR Kit Figure 3

Next

Click for expanded view

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.

ComponentCat. TM29350 (100 preps)Cat. TM29310 (100 preps)
MDx TaqMan 2X PCR Master Mix2 x 700 μL
S. aureus Primer & Probe Mix280 μL280 μL
S. aureus Positive Control150 μL150 μL
Nuclease-Free Water (Negative Control)1.25 mL1.25 mL
Product Insert11

Other Products

4x14x5ml Decapping Centrifuge Rotor

IVD6672C MagPure Pathogen RNA Kit

D-Glucosamine Assay Kit