Lyophilized format designed for room temperature shipping
Available in TaqMan format for analysis
Norgen’s Vibrio cholerae TaqMan PCR Lyophilized Kit is designed for the detection of Vibrio cholerae specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s Vibrio cholerae TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of Vibrio cholerae specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
All kit components should be stored at -20°C upon arrival.
Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Each kit is provided with 4 tubes of 2X PCR Master Mix and each tube is enough to run 25 reactions. It is not necessary to reconstitute all Master Mix tubes at once. The Master Mix tubes can be reconstituted as and when needed.
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
Gel images of different ranges of library size selection. Sheared human genomic DNA was used as input.
.
Library size selection is an enrichment of a specific range of library sizes for NGS library preparations. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads, or SPRI (Solid Phase Reversible Immobilization) beads, is well used for the purification of DNA due to their reversible DNA binding. The NGS library can be size-selected by the magnetic beads or SPRI beads. The properties of the magnetic beads can be changed for a specific range of DNA binding. The contaminants and other unwanted components in the libraries can also be removed during size selection.
Specific ranges of NGS libraries can be selected using magnetic beads with different buffer compositions. The first DNA-beads binding step, also called the right-side clean-up, removes large NGS library fragments. The large NGS library fragments that bind to the beads are discarded with the beads pellet. The desired NGS library fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-DNA binding, also called the left-side clean-up. After the rinsing step, the NGS library fragments with the dual selection are eluted in water or an appropriate buffer. The magnetic beads method has great advantages over time-consuming column purification and tedious gel-based purification.
NGS library size selection with dual clean-ups.
.
Library size selection for long-read sequencing only requires a single clean-up. In this case, only the large library fragments are bound to the beads, while other small library fragments are discarded with the supernatant. The selected larger library fragments are eluted in water or an appropriate buffer after the rinsing step.
NGS library size selection with single clean-up for >5 kb and >10 kb libraries.
The RNAok™ RNase Inhibitor is a recombinant mammalian RNase inhibitor which possesses very high affinity for eukaryotic pancreatic-type ribonuclease. The RNAok™ RNase Inhibitor forms a 1:1 complex with pancreatic RNase A by noncovalent binding, presenting a noncompetitive inhibitory activity on these pancreatic enzymes. RNAok™ RNase Inhibitor is active against RNase A, RNase B, RNase C but not RNAse H, RNase I, RNase T1, RNase T2, and S1 nuclease. RNAok™ RNase Inhibitor is compatible with RT-PCR enzymes such as AMV, M-MLV and ExcelRT™ Reverse Transcriptase or Taq DNA polymerase.
Application
cDNA synthesis
in vitro translation
in vitro transcription
One-step RT-PCR
Separation and identification of specific ribonuclease activities
Storage Buffer
40 mM HEPES-KOH (pH 7.5), 100 mM KCl, 8 mM DTT, 0.1 mM EDTA, stabilizer and 50% (v/v) glycerol
Storage
-20°C for 24 months
Document
The RNAok™ RNase Inhibitor is a recombinant mammalian RNase inhibitor which possesses very high affinity for eukaryotic pancreatic-type ribonuclease. The RNAok™ RNase Inhibitor forms a 1:1 complex with pancreatic RNase A by noncovalent binding, presenting a noncompetitive inhibitory activity on these pancreatic enzymes. RNAok™ RNase Inhibitor is active against RNase A, RNase B, RNase C but not RNAse H, RNase I, RNase T1, RNase T2, and S1 nuclease. RNAok™ RNase Inhibitor is compatible with RT-PCR enzymes such as AMV, M-MLV and ExcelRT™ Reverse Transcriptase or Taq DNA polymerase.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Mannitol
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
5 to 75 μg of D-mannitol per assay
Limit of Detection:
0.50 mg/L
Reaction Time (min):
~ 4 min
Application examples:
Wine, chewing gum, dietetic foods, candies, cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Novel method
The D-Mannitol test kit is suitable for the rapid and specific measurement and analysis of D-mannitol in food, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).