Lyophilized format designed for room temperature shipping
Available in TaqMan format for analysis
Norgen’s EBV TaqMan PCR Lyophilized Kit is designed for the detection of EBV specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s EBV TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of EBV specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
All kit components should be stored at -20°C upon arrival.
Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
Component
Cat. TM41050L (100 preps)
Cat. TM41010L (100 preps)
MDx TaqMan 2X PCR Master Mix (Lyo)
4 x 350 μL
–
EBV Primer & Probe Mix (Lyo)
280 μL
280 μL
EBV Positive Control (Lyo)
150 μL
150 μL
Nuclease-Free Water (Negative Control)
3 x 1.25 mL
1 x 1.25 mL
Product Insert
1
1
Other Products
96-Well Post Magnetic Plate
Product Info
Document
Product Info
The Permagen Post magnet low elution plate was designed for use in manual or automation applications where volumes as low as 5 µL are required. The post magnets will create bead pellets to one quadrant of the well making aspiration easier and accidental bead disruption less likely
SBS SLAS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
The Permagen Post magnet low elution plate was designed for use in manual or automation applications where volumes as low as 5 µL are required. The post magnets will create bead pellets to one quadrant of the well making aspiration easier and accidental bead disruption less likely
Salmonella enterica have emerged as significant foodborne pathogens that pose a serious public health problem. The symptoms of salmonellosis may include diarrhea, fever, vomiting, and abdominal cramps with elderly, new-born, and immunocompromised individuals the most susceptible. S. enterica is a facultatively anaerobic Gram-negative bacterium that could survive low temperatures and freezing. The majority of the 1.3 billion annual cases of Salmonella-caused human gastroenteritis result from ingestion of contaminated food products, such as raw or undercooked meat, seafood, and eggs, as well as raw or unpasteurized milk and dairy products. Salmonella infections are also contracted following consumption of fresh fruits or vegetables that have been contaminated by infected fertilizer.
Salmonella enterica TaqMan PCR Kit, 24 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
The Salmonella enterica TaqMan PCR Kit Dx is shipped on dry ice. The components of the kit should be frozen upon arrival. If one or more of the components is not frozen when the kit is received, or if any of the components have been compromised during shipment, please contact Norgen Biotek for assistance. All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 3 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. TM32100 (24 rxns)
MDx TaqMan 2X PCR Master Mix Dx
550 µL
S. enterica Primer & Probe Mix Dx
2 x 70 µL
S. enterica Positive Control Dx – 200,000 copies/μL
HiDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) or allele-specific amplification (ASA).Please note: This DNA polymerase is also available as a nuclease deficient variant, featuring higher robustness towards potential PCR inhibitors and compatibility with real-time dyes such as our GreenDye.Benchmarking with products of competitors conducted by us and others show that the HiDi® DNA polymerase family is the first choice for highly selective PCRs, such as genotyping by allele-specific PCR, HLA genotyping, analysis of single CpG methylation sites or the detection of mutations in a high background of wild-type sequences. By using HiDi® Taq DNA polymerase, less than 10 copies of a mutation can be detected in a background of >10.000 wild-type copies straight away without any other tedious assay optimization.HiDi® Taq DNA polymerase harbours a nuclease function and therefor is also suitable for use with hydrolysis probes (TaqMan® probes etc.). It has also been shown that HiDi® DNA polymerase family is highly suitable for quality control and mutation identification in CRISPR-Cas or TALEN-based applications.Several independently conducted studies show that HiDi® Taq DNA polymerase is ideally suited for use in asPCR in numerous research areas ranging from mutation detection to genome editing. (read more) For research use and further manufacturing.In case you are aiming to use our RUO products as components or for your development of e.g. an IVD medical device, please contact us.
Casestudies: HiDi® DNA Polymerase: Applications from mutation detection to genome editing (read more)
Example Primer Design
Matching vs. mismatching nucleotide is placed at the 3′-end of the primer for best discrimination results.
Example Results – There´s no accounting for taste
Cilantro: some people love it in their food, some hate it. Here we are detecting a genomic SNP (rs72921001) in HeLa genomic DNA. This SNP is reported to be close to a number of genes coding for olfactory receptors. (Reference: Eriksson N. et al. (2012), “A genetic variant near olfactory receptor genes influences cilantro preference.”)
Considering, that only the C-allele specific primer is extended and yielding in a specific amplicon, we can conclude a genetic predisposition in disliking cilantro, as this SNP is significantly associated with detecting a soapy taste to cilantro.
Allele-specific PCRs were performed from 1 ng/µl of HeLa gDNA in the presence of a realtime dye, indicating the amplification of the C-allele specific primer only. The A-allele specific primer is discriminated, thus not amplified up to 50 cycles.
PCR products were subsequently analysed on a 2.5% agarose gel. Specific product is visualized by ethidium bromide staining at the amplicon length of 109 bp.
Document
HiDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) or allele-specific amplification (ASA).
Please note: This DNA polymerase is also available as a nuclease deficient variant, featuring higher robustness towards potential PCR inhibitors and compatibility with real-time dyes such as our GreenDye.