16S V2-V3 Library Preparation Kit for Illumina

Facebook
X
Pinterest
Email

Detail

Overview

  • Protocol optimized for DNA isolated from a diversity of samples including stool, soil, water, saliva, plant, urine, skin, and more
  • Simple and quick workflow: library could be prepared in less than 5 hours
  • Component of Norgen’s metagenomics workflow
  • A single NGS run can be prepared with up to 384 unique dual-index libraries

Sample type purification kit guide 

The 16S V2-V3 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V2-V3 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.

The 16S V2-V3 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V2-V3 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.16S Library Prep

Details

Supporting Data

Figure 1 / 3

Previous

Figure 1: 16S V2-V3 PCR1 Amplification
Figure 1: 16S V2-V3 PCR1 Amplification
Figure 2: 16S V2-V3 Indexed Libraries
Figure 3: BioAnalyzer Trace of the 16S V2-V3 Indexed Library

Next

Click for expanded view

Minimum amount of starting material:2.5 µL of DNA (5 ng/µL)
Time to complete library preparation:4 hours

Storage Conditions and Product Stability
Norgen’s 16S V2-V3 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.

All kit components should remain stable for at least 1 year when stored at the specified storage conditions.

StepComponentCat. 70300 (24 preps)Cat. 70310, 70320, 70330, 70340 (96 preps)
Amplicon PCR (PCR 1)MGX Master Mix330 µL1,320 µL
16S V2-V3 Primer Mix70 µL280 µL
Index PCR (PCR 2)Indexing Master Mix660 µL2 x 1,320 µL
N7xx Index Primer50 µL50 µL
S5xx Index Primer70 µL70 µL
PCR Clean-UpResuspension Buffer2 x 1,250 µL2 x 5,000 µL
Nuclease-free water1,250 µL1 x 6,000 µL

Other Products

[QP5210] Q-PAGE™ TGN Precast Gel (Midi, 12 wells, 10%), 10 gels

endo-BCN-PEG2-alcohol

Pilot-Scale Freeze Dryer