High yield and high purity DNA ready for any application
Available in a variety of formats to properly suit your needs
Compatible with blood collected on a variety of commercially available tubes
These kits allow for the isolation of DNA from the blood of various species, including humans and will recover genomic DNA, mitochondrial DNA, viral DNA and bacterial DNA. The purified DNA is of excellent quality and yield and completely compatible with any downstream application including PCR, qPCR and genotyping.
Blood DNA Isolation Mini Kit
Norgen’s Blood DNA Isolation Mini Kit is designed for the rapid preparation of DNA from up to 200 µL of whole blood using a rapid spin column protocol. Preparation time for a single sample is less than 30 minutes and each kit contains sufficient materials for 50 preparations.
Blood DNA Isolation Midi Kit
Norgen’s Blood DNA Isolation Kit is designed for the rapid spin column preparation of DNA from 0.3 to 2 mL volumes of whole blood. Preparation time for a single sample is less than 30 minutes, and each kit contains sufficient materials for 20 preparations.
Blood DNA Isolation Maxi Kit
This kit is designed for the rapid preparation of DNA from 3 mL up to 10 mL of whole blood. Preparation time for a single sample is less than 30 minutes.
Blood DNA Isolation 96-Well Kit (High Throughput)
This kit provides a rapid method for the high-throughput isolation of DNA from up to 200 µL of whole blood. Fast and easy processing using either a vacuum manifold or centrifugation.
Blood DNA Isolation Kit (Magnetic Bead System)
Norgen’s Blood DNA Isolation Kit (Magnetic Bead System) is designed for the rapid preparation of genomic DNA from up to 200 µL of whole blood from various species, including human. Purification is based on magnetic beads as the separation matrix. Norgen’s magnetic beads bind DNA under optimized salt concentrations and releases the bound DNA under low salt and slightly alkali conditions. The genomic DNA is preferentially purified from other cellular proteinaceous components. Typical yields of genomic DNA will vary depending on the cell density of the blood sample. The purified genomic DNA is fully digestible with all restriction enzymes tested, and is completely compatible with downstream applications including real-time PCR, NGS and microarray analysis.
Blood DNA Isolation 96-Well Kit (High Throughput Magnetic Bead System)
96-well format for high throughput applications. Purification with the 96-well plates can be integrated with a robotic automation system.
40 minutes (hands-on time Cat. 59800) 50 minutes (hands-on time Cat. 62600)
* Average DNA yield will vary depending on the donor
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment. The kit contains a ready-to-use Proteinase K, which is dissolved in a specially prepared storage buffer. The buffered Proteinase K is stable for up to 1 year after the date of shipment when stored at room temperature.
Component
Cat. 46300 (50 preps)
Cat. 46380 (100 preps)
Cat. 51400 (20 preps)
Cat. 31200 (12 preps)
Cat. 46350 (192 preps)
Cat. 59800 (50 preps)
Cat. 62600 (192 preps)
Lysis Buffer B
20 mL
2 x 20 mL
2 x 40 mL
2 x 110 mL
2 x 40 mL
20 mL
1 x 40 mL 1 x 20 mL
Solution WN
18 mL
2 x 18 mL
55 mL
55 mL
55 mL
18 mL
55 mL
Wash Solution A
18 mL
2 x 18 mL
2 x 38 mL
2 x 38 mL
2 x 38 mL
–
–
Elution Buffer B
30 mL
2 x 30 mL
30 mL
30 mL
2 x 30 mL
15 mL
1 x 30 mL 1 x 15 mL
Proteinase K in Storage Buffer
1.2 mL
2 x 1.2 mL
4.4 mL
8 mL
4.5 mL
1.2 mL
4 mL
Magnetic Bead Suspension
–
–
–
–
–
2 x 1.1 mL
8.5 mL
Maxi Spin Columns
–
–
–
12
–
–
–
Mini Spin Columns
50
100
–
–
–
–
–
Midi Spin Columns
–
–
20
–
–
–
–
96-Well Plate
–
–
–
–
2
–
2
Adhesive Tape
–
–
–
–
4
–
2
Collection Tubes
50
100
20
12
–
–
–
96-Well Collection Plate
–
–
–
–
2
–
–
Elution Tubes
50
100
20
12
–
50
–
96-Well Elution Plate
–
–
–
–
2
–
2
Product Insert
1
1
1
1
1
1
1
Other Products
α-Glucuronidase Assay Kit
Product Info
Document
Product Info
K-AGLUA
50 assays (manual) / 200 assays (microplate)
Content:
50 assays (manual) / 200 assays (microplate)
Shipping Temperature:
Ambient
Storage Temperature:
Short term stability: 2-8oC, Long term stability: See individual component labels
The α-D-Glucuronidase test kit is a simple, reliable and accurate method for the measurement and analysis of α-D-glucuronidase in various enzyme preparations. The kit contains a pure aldotriouronic acid substrate and an α-D-glucuronidase (GH67) control enzyme.
New, improved substrate.
This kit contains highly purified, borohydride reduced aldotriouronic acid with a terminal α-D-glucuronic acid substitution, which is an excellent substrate for α-D-glucuronidases from GH67. This substrate can be also used for the measurement of α-D-glucuronidases from GH115, however the rate of hydrolysis compared to GH67 is reduced. Previously this kit contained a mixture of borohydride reduced aldouronic acids (tri:tetra:penta).
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The α-D-Glucuronidase test kit is a simple, reliable and accurate method for the measurement and analysis of α-D-glucuronidase in various enzyme preparations. The kit contains a pure aldotriouronic acid substrate and an α-D-glucuronidase (GH67) control enzyme.
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.
DNA amplification made possible with a TwistAmp® Basic kit. Contains all the enzymes and reagents necessary for the amplification of DNA, the user needs only supply primers and template. Even PCR primers can work using TwistAmp® Basic. TwistAmp® Basic has been used for solid-phase, tailed primers, aptamers, electrochemistry and microarray applications. See manual for more information. Click to order oligonucleotides.
Perfect for: End-point gel electrophoresis DNA detection, down-stream applications (e.g. sub-cloning)
Document
DNA amplification made possible with a TwistAmp® Basic kit. Contains all the enzymes and reagents necessary for the amplification of DNA, the user needs only supply primers and template. Even PCR primers can work using TwistAmp® Basic. TwistAmp® Basic has been used for solid-phase, tailed primers, aptamers, electrochemistry and microarray applications. See manual for more information. Click to order oligonucleotides.