The Flex caddy allows the Thermocycler GEN2 to be installed on the Opentrons Flex deck and sit below the deck, enabling below-deck cable routing and labware placed on top of modules to remain closer to the deck surface. The calibration adapter is used to calibrate the location of the Thermocycler. Caddies and calibration adapters are specific to the type of module.
Note: This item does not include the Thermocycler Module. The module is available with or without the Flex Caddy and Calibration tool: Thermocycler Module GEN2
Detail
The Flex caddy allows the Thermocycler GEN2 to be installed on the Opentrons Flex deck and sit below the deck, enabling below-deck cable routing and labware placed on top of modules to remain closer to the deck surface. The calibration adapter is used to calibrate the location of the Thermocycler. Caddies and calibration adapters are specific to the type of module.
Note: This item does not include the Thermocycler Module. The module is available with or without the Flex Caddy and Calibration tool: Thermocycler Module GEN2
Other Products
TGM12 Table top capillary vessel Haematocrit centrifuge
Product Info
Document
Product Info
TGM12 Table top capillary vessel Haematocrit centrifuge
Application:
Measure the ratio of blood corpuscle and separate microblood and micro solution.
Model: TGM12 Table top high speed capillary vessel centrifuge
Features:
Brushless DC motor, free maintenance, no powder pollution, micro computer control, digital display indicates the time、speed and RCF. Electric lid lock、 over speed and imbalance protection. The centrifuge body is made of high quality steel, Safe and reliable.
Features of the sDNASEQ E.coli Residual DNA Quantitation kit include:
Simpler and Rapid
Only three steps will be need for Sample Preparation and All components of the Sample Preparation Kit can be stored at room temperature.
Only one Reagent for qPCR;
Only 1.5 hours will be needed for the whole test.
Accurate
Perfect amplification curve, good amplification efficiency and good precision.
Highly sensitive quantitation using proven TaqMan™ real-time qPCR technology.
Limit of Detection (LoD): 1 fg/μL; Limit of Quantification (LoQ):5 fg/μL.
The recovery rate of different concentration samples in the linear range is between 70% and 130%
Kit Performance
Fig 1. Only three steps will be need for Sample Preparation and only 20 minitutes will be taken for Sample Preparation.
Fig 2. Seven concentration samples of 5fg/μL, 10fg/μL, 20fg/μL, 30fg/μL, 300fg/μL, 3pg/μL, 30pg/μL, 300pg/μL were detected. CV of each concentration was < 30%, Regression coefficient associated with standard solutions was 0.99975, and amplification efficiency was 100.068%.
Fig 3. Four concentration samples of 5fg/μL, 10fg/μL, 20fg/μL, and 30fg/μL were detected, and 10 multiple holes were detected for each concentration. The detection values of 5fg/μL and above were CV <30%.
Fig 4. DNA recovery can be determined by including samples spiked with known DNA amounts which are prepared from the corresponding DNA standards. Typically, the range for this value varies from 70% to 130%.
Fig 5. Only one Reagent for qPCR MIX.
Document
Note: Price not include shipment & duty, contact us to get full quote. The resDNASEQ E.coli Residual DNA Quantitation kit is designed for the quantification of residual DNA from E. coli, in cell lines which are used for production of biopharmaceutical products. The resDNASEQ E.coli Residual DNA Quantitation kit use TaqManTM quantitative PCR to perform rapid, specifc quantitation of femtogram levels of residual host-cell or plasmid DNA. The kit was developed to meet the sensitivity requirements defined by WHO (10 ng E. coli DNA per therapeutic dose).
CE-IVDR marked in accordance with the European Commission Regulation (EU) No. 2017/746.
Available for sale in Canada (Dx17200, Dx24300)
Ideal for use in in vitro diagnostic workflows
Extract high quality & quantity total RNA including miRNA
No phenol step required
Bind & elute all RNA irrespective of size or GC content, without bias
Very sensitive & linear down to a few cells without the need for carrier RNA
Convenient & fast spin column format
Available in 96-Well and 96-Well (Deep Well) formats for high throughput automation
Isolate from a wide variety of specimens
Purified RNA is suitable for a variety of downstream applications
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s Total RNA Purification Kits Dx provide rapid methods for the isolation and purification of total RNA from tissue samples, blood, plasma, serum, saliva, bacteria, yeast, fungi and viruses for subsequent in vitro diagnostic use. Extract high quality and purity RNA with excellent RIN values and A260/A280 suitable for downstream applications including qRT-PCR, RT-PCR, microarrays, NGS and more.
Total RNA Purification Kit Dx (Spin Column)
This kit is designed to be used with any downstream application employing enzymatic amplification or other enzymatic modifications of RNA followed by signal detection or amplification. Any diagnostic results generated using the RNA isolated with Norgen’s Total RNA Purification Kit Dx in conjunction with an in vitro diagnostic assay should be interpreted with regard to other clinical or laboratory findings.
Total RNA Purification 96-Well Kits Dx (High Throughput and High Throughput Deep Well)
Thess 96-well kits provide a rapid method for the high-throughput isolation and purification of total RNA in 30 minutes using vacuum manifold, plate centrifuge, or liquid handlers with vacuum capabilities. Total RNA can be isolated from a broad range of sample sources including cultured cells, tissues, blood, serum, plasma, bacteria, yeast, fungi, and viruses.
Intended Use
To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used. Norgen’s Total RNA Purification Kits Dx are intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques. Norgen’s Total RNA Purification Kits Dx do not provide a diagnostic result. It is the sole responsibility of the user to use and validate the kit in conjunction with a downstream in vitro diagnostic assay.
NOTE: This product is not available for sale in the United States.
Average Yield HeLa Cells (1 x 106 Cells) E. coli (1 x 109 cells) Brain (10 mg) Liver (10 mg) Blood (50 μL, Hamster)
15 μg 50 μg 9 μg 26 μg 1 μg
Maximum Amount of Starting Material: Whole Blood Plasma/Serum Bacteria Yeast Fungi Plant Tissue
100 µL150 µL1 x 109 cells1 x 108 cells 40 mg 40 mg
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. These reagents should remain stable for at least 1 year in their unopened containers.