Universal Human IgG/IgM Lateral Flow Serology Kit (Gold)
Facebook
X
Pinterest
Email
Antibody tests are a method of choice to determine if a person has been exposed to a pathogen or not. They are also incredibly valuable in the detection of autoantibodies that can be found in human autoimmune disorders. In this test, a biotinylated antigen (User supplied) is mixed with a biotinylated rabbit IgG (bind to goat anti rabbit control line) and sample (human sera or plasma) is simply mixed into with the specially designed assay running buffer in a well of the supplied 96-well plate, mixed and is then added to the sample port of the cassette. Generally, the reaction is complete in 10-15 minutes. It is very important to note that the relative stoichiometry between the biotinylated antigen, biotinylated rabbit IgG added, and the streptavidin gold is critical for assay optimization. The appropriate concentration of biotinylated antigen to use with strips is dependent upon the purity and sequence and a standard curve can be used to determine the relative ratio (generally between 1ng-100ng per test). A positive control line (biotin-rabbit IgG) antibody will bind to the goat anti rabbit (GAR) line on the test to ensure the assay is running appropriately.
Attogene’s Human IgG/IgM universal lateral flow assay kit is a ready-to-use, universal test strip, which is based on the lateral flow technology that uses gold particles containing streptavidin to conveniently capture biotinylated antigens. The device is designed to easily develop qualitative or quantitative rapid test systems for detection of anti-human IgG and IgM antibody that react to the any antigen that can be biotinylated (i.e. viral antigen, autoimmune antigen) and is easily customizable providing every laboratory with the possibility to perform assay feasibility.
Other Products
FBS Exosome Depletion Kits
Product Info
Document
Product Info
Overview
Efficient depletion of bovine exosomes from Fetal Bovine Serum
Deplete exosome-sized vesicles from versatile FBS volumes
No protease treatment required
No time-consuming ultracentrifugation
No precipitation reagents required
No overnight incubation required
Exosome depletion confirmed by reduction of bovine miRNAs below detectable levels
The depleted FBS provides the same cellular growth rates as the standard FBS
Purification is based on Norgen’s proprietary Silicon Carbide resin matrix
Norgen’s FBS Exosome Depletion Kits provides a quick and easy protocol for the depletion of bovine exosomes from FBS prior to using it as a growth supplement in your culture medium. The FBS recovered from the depletion process is exosome-depleted and does not contain any quantifiable bovine miRNAs. Moreover, the exosome-depleted FBS will support the growth of your cells of interest similar to the non-depleted FBS. Norgen’s kits allow for the processing of different FBS volumes. The depletion is based on Norgen’s proprietary resin. These kits provide a clear advantage over other available kits in that they do not require ultracentrifugation, any special instrumentation, precipitation reagents or any protease treatments. More importantly, the depletion process is an inexpensive method for exosome depletion from FBS, as compared to the expensive current ready-to-use exosome-depleted media available on the market.
Background
Most culture medium used for the growth and propagation of cells in culture require the addition of fetal bovine serum (FBS) as a growth supplement to media. FBS is obtained from bovine (cow) serum, and therefore contains large quantities of bovine exosome vesicles. These exosomes may interfere with some types of studies, or may lead to unreliable results when studying the exosomes shed from your cells of interest in normal culture conditions. Therefore, the use of exosome-depleted FBS is highly recommended for many types of studies.
Up to 140 mL (FBS Exosome Depletion Kit I (Slurry Format) Up to 280 mL (FBS Exosome Depletion Kit II (Slurry Format)
Depletion
Deplete exosome-sized vesicle
Bovine miRNA
No detectable bovine miRNA
Time to Complete 6 Purifications
40 minutes
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Primer and probe mix (150 reactions)
Reverse Transcription, target specific primers (RNA genome viruses only)
Copy number standard curve (sufficient for multiple standard curves)
Internal extraction control – Read through VIC channel*
Endogenous control (150 tests)
RNAse/DNAse free water
*alternative fluorophores available on request