Functionally tested GAM conjugated gold Perfect for Lateral Flow Development and use in final product 40nm gold particles conjugated to GAM are offered in 10 OD 1mL size. If a different OD or amount is required please
Goat Anti-Rabbit (GAR) Conjugated Colloidal Gold for Lateral Flow (1mL of 10OD)
Product image shows functional testing of Goat Anti Mouse (GAM) 40nm colloidal gold on a lateral flow test.
Our products are produced in a state-of-the-art manufacturing facility that enable rapid turnaround times while ensuring batch to batch consistency and reliability.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money Rapid detection of all clinically relevant subtypes Positive copy number standard curve for quantification Highly specific detection profile High priming efficiency Broad dynamic detection range (>6 logs) Sensitive to < 100 copies of target
Accurate controls to confirm findings
NGS Library Quantification Standards With PCR Primers
Product Info
Document
Product Info
The NGS Library Quantification Standards with PCR Primers (for illumina platform) were developed for quantification of the NGS library concentration for illumina sequencing platform. It is comprised of Library Standards (six 10-fold dilutions) and a primer mix.
Quantification of the NGS library of the amplifiable molecules is critical for the quality of the sequencing data. Adequate library concentration will maximize sequencing capacity. Poor library concentration results in either low or high cluster density on the flow cell, which can lead to low sequencing capacity.
It is not accurate to measure the concentration of NGS library with standard DNA quantification methods such as spectrophotometer or fluorometer. QPCR is the best way for library quantification with high consistency and reproducibility of library quantitation.
BioDynami Library Quantification Standards with PCR Primers (for illumina platform): Amplification curve of 6 standards.
Our reagent is a highly sensitive, Real time PCR-based quantification that specifically designed for NGS libraries using illumina sequencing platform. The amplification uses illumina adaptor sequences as primers, and only the fully adaptor-ligated libraries will be amplified. Therefore the reagent provides an accurate estimation of the library concentration based on true sequenceable illumina libraries. In addition, this kit can also be used for confirmation of ligation reaction after completion of library preparation.
Our library quantification standards is compatible with commercial SYBR Green based QPCR reagents. This makes it more flexible for scientists who want to use their real time PCR reagent. Quantification of library concentration is achieved by comparison with a standard curve generated from the Library Standards.
Document
The NGS Library Quantification Standards with PCR Primers (for illumina platform) were developed for quantification of the NGS library concentration for illumina sequencing platform. It is comprised of Library Standards (six 10-fold dilutions) and a primer mix.
HiPure PCR Pure Micro Kit uses proprietary chemistry and HiPure technology to recover DNA fragments between 60bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Details
Specifications
Features
Specifications
Main Functions
Recover DNA fragments between 60bp-20kbp from PCR products and enzymatic reaction solution
Applications
PCR, sequencing, labeling reactions, ligations and restriction digestion, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
PCR products, enzymatic reaction solution
Sample amount
10-200μl
Recovery
≥80%
Elution volume
≥7μl
Time per run
≤10 minutes
Liquid carrying volume per column
800µl
Binding yield of column
10µg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
High recovery efficiency – ≥80% DNA recovery
Fast – isolation can be completed in 10 minutes by column gel method
Kit Contents
Contents
D212002
D212003
Purification Times
100 Preps
250 Preps
Buffer DP
60 ml
120 ml
Buffer DW2
20 ml
50 ml
Elution Buffer
15 ml
30 ml
HiPure DNA Micro Columns
100
250
2 ml Collection Tubes
100
250
Storage and Stability
The Kit should be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve.
Document
HiPure PCR Pure Micro Kit uses proprietary chemistry and HiPure technology to recover DNA fragments between 60bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.