Primer and probe mix (150 reactions)
Reverse Transcription, target specific primers (RNA genome viruses only)
Copy number standard curve (sufficient for multiple standard curves)
Internal extraction control – Read through VIC channel*
Endogenous control (150 tests)
RNAse/DNAse free water
*alternative fluorophores available on request
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Other Products
[TP1000] ExcelTaq™ Taq DNA Polymerase, 5 U/μl, 500 U
Product Info
Document
Product Info
Description
ExcelTaq™ Taq DNA Polymerase is a recombinant thermo-stable Taq DNA polymerase expressed and purified from an E. coli strain carrying the cloned gene. With a high DNA synthesis rate and high thermo-stability, ExcelTaq™ Taq DNA Polymerase is suitable for common and specialized PCR applications.
Features
5’→3′ DNA polymerase activity
5’→3′ exonuclease activity
No detectable 3’→5′ exonuclease (proofreading) activity
Generates PCR products with 3’-dA overhangs
Thermo-stable – half-life lasts for more than 40 min at 95°C
Applications
Routine PCR
Amplification of DNA fragments up to 8 kb
Generation of PCR products for TA cloning
DNA labeling
Storage
-20°C for 24 months
Document
ExcelTaq™ Taq DNA Polymerase is a recombinant thermo-stable Taq DNA polymerase expressed and purified from an E. coli strain carrying the cloned gene. With a high DNA synthesis rate and high thermo-stability, ExcelTaq™ Taq DNA Polymerase is suitable for common and specialized PCR applications.
Human Papillomavirus (HPV) 6/16 TaqMan PCR Detection Kits
Product Info
Document
Product Info
Overview
Detection kits for the HPV 6/16
Available in TaqMan format for analysis
More than 70 types of human papillomavirus (HPV) have been identified, and are generally classified as high-risk or low-risk depending on their relationship or lack of relationship with cancer and high-grade cervical intraepithelial neoplasia (CIN 2-3). HPV viruses are predominantly sexually transmitted and high-risk HPV types are a major risk factor for development of cervical cancer. HPV 16 has been considered as a high-risk cancer associated HPV type. The low-risk HPV type 6 has been associated with the presence of genital warts. There are many other low-risk HPV types that are not associated with genital warts or cervical cancer. Until now, HPV cannot be cultured in vitro, and immunological tests are inadequate to determine the presence of HPV cervical infection. On the other hand, biopsies can be analyzed by nucleic acid hybridization to directly detect the presence of HPV DNA.
HPV 6/16 TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
HPV 6/16 TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
TaqMan Probe Cat. TM42050 (100 preps)
TaqMan Probe/Primer and Control Set Cat. TM42010 (100 preps)
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings