Attogene’s Mercury Lateral Flow Kit can be used for the screening of Mercury in water samples at 10 ppb in the field.
Mercury contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Mercury ion accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking Mercury-contaminated food and water include brain, heart, kidney, lungs and immune system problems for adults, and the physical and mental development delays in infants and children. Attogene’s Mercury Lateral Flow test gives results conforming of 10ppb or greater. Using the supplied pipette, simply fill the vial with your water sample, place the water into the sample port and wait 5 minutes.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Primer and probe mix (150 reactions)
Reverse Transcription, target specific primers (RNA genome viruses only)
Copy number standard curve (sufficient for multiple standard curves)
Internal extraction control – Read through VIC channel*
Endogenous control (150 tests)
RNAse/DNAse free water
*alternative fluorophores available on request
This kit is suitable for extracting total pathogen nucleic acid from a variety of clinical samples such as blood, serum, plasma, swab soaking solution, fluid accumulation and homogenate solution. This kit is designed to remove host cells background nucleic acid and enrich pathogen nucleic acid (including viral/bacterial/fungal DNA/RNA) from the sample. Purified DNA/RNA is ready for downstream applications such as PCR, virus detection, tNGS and other related experiments.
Details
Specifications
Features
Specifications
Main Functions
Extract Pathogen RNA/DNA from 0.5-1.5ml whole blood, plasma, serum, body fluid, homogenate suspension, culture solution, cell suspension, soaking solution or concentrate pathogen solution for tNGS application, remove host background nucleic acid.
Applications
Real Time PCR, biochip analysis, NGS
Products
Pathogen DNA / RNA
Purification method
Polydisperse magnetic beads
Purification technology
Magnetic beads technology
Process method
Manual or automatic
Sample type
whole blood, plasma, serum, body fluid, homogenate suspension, culture solution, cell suspension, soaking solution or concentrate pathogen solution
Sample amount
0.5 – 1.5 ml
Adaptive instrument
Nucleic acid extractor, pipetting workstation
Principle
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Protease. After adding magnetic particles and binding solution, DNA/RNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA/RNA was eluted by Buffer NFW.
Kit Contents
Contents
R667200C
R667202C
Purification Times
24 Preps
96 Preps
2ml Bead Tube (0.4g)
24
96
DNase I (Powder)
10 mg
15 mg
DNase Buffer
5 ml
20 ml
Protease Dissolve Buffer
3 ml
8 ml
Lysis Buffer LBX1
40 ml
180 ml
Buffer TL
5 ml
20 ml
Proteinase K
24 mg
120 mg
MagBind Particles N9
1.2 ml
5 ml
Buffer MLB
30 ml
120 ml
Buffer MW1*
13 ml
110 ml
Buffer MW2*
10 ml
50 ml
Buffer AVE
10 ml
20 ml
Storage and Stability
Proteinase K, DNase I powder and MagPure Particles N9 should be stored at 2–8°C upon arrival. However, short-term storage (up to 8 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This kit is suitable for extracting total pathogen nucleic acid from a variety of clinical samples such as blood, serum, plasma, swab soaking solution, fluid accumulation and homogenate solution. This kit is designed to remove host cells background nucleic acid and enrich pathogen nucleic acid (including viral/bacterial/fungal DNA/RNA) from the sample. Purified DNA/RNA is ready for downstream applications such as PCR, virus detection, tNGS and other related experiments.