Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
150 reactions
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
A custom designed PACE® Genotyping Assay, designed to your target sequence. Compatible with all PACE genotyping master mixes.
About
PACE (PCR Allelic Competitive Extension) genotyping chemistry is a homogeneous, PCR-based allele-specific technology for the analysis of DNA sequence variants, most commonly SNPs (Single Nucleotide Polymorphisms) and Indels (insertion / deletions).
PACE genotyping chemistry is comprised of two parts:
PACE Genotyping Assay: two allele-specific forward primers and one common, reverse primer. The allele-specific forward primers each have different 3′ terminal bases reflecting the target variant, and a unique 5’ tail sequence which is incorporated as part of the fluorescent signal mechanism.
PACE Genotyping Master Mix: containing all remaining components required for PCR and the generation of fluorescent signals. PACE Genotyping Master Mix contains a novel, universal, fluorescent reporting cassette to produce machine-readable fluorescent signals (FAM and HEX) corresponding to the assay genotypes.
When combined with sample DNA, these components create a PACE Genotyping Reaction, as illustrated in the figure below.
We have extensive knowledge and experience in assay design, especially when it comes to allele-specific PCR. PACE Genotyping Assays are available to purchase either Validated and Unvalidated. Validated assays require customer DNA to validate and optimise, for guaranteed performance. Unvalidated assays are designed in silico and supplied untested.
REQUIRED COMPONENTS
qPCR machine or Thermocycler + Fluorescent plate reader
PCR plate or equivalent and appropriate optically clear seal
Template DNA
PCR-grade water
PACE Genotyping Master Mix or PACE 2.0 Genotyping Master Mix
STEPS TO YOUR PACE GENOTYPING ASSAY DESIGN
Place your order on this page. Our support team will contact you by email.
Fill out an Assay Design Template form with all the information we need to process your custom PACE Genotyping Assay order. We will email you a copy of the template when we first contact you, or your can download a copy here.
Using the information you provide us, we will create your PACE Genotyping Assay designs, order the oligos, and send you design sequences.
Once we receive the oligos, we assemble the assay(s) and then ship an aliquot to you (unvalidated) or test on your DNA samples before shipping the aliquot to you (validated).
Document
qPCR machine or Thermocycler + Fluorescent plate reader
PCR plate or equivalent and appropriate optically clear seal
Template DNA
PCR-grade water
PACE Genotyping Master Mix or PACE 2.0 Genotyping Master Mix
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Details
Specifications
Features
Specifications
Recommended application
Small amounts of nucleic acid isolation, viral nucleicacid from cell free samples
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/F, 3 layers
Membrane aperture
0.7μm
Maximum binding yield of plasmid
30 μg
Maximum yield of alcohol mediated Binding
200 μg
Single liquid carrying capacity of column
800 μl
Minimum elution volume
30 μl
Withstand centrifugal force
16,000 x g
Centrifuge
Small high speed centrifuge (2ml)
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silicagel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No.
Product Name
Package
C13112
HiPure Viral Mini Column I (3 x GF/F)with 2ml Collection Tubes
1000/Bag
Purchase Guide
Item No.
Product Name
Membrane type/number of layers
Collection tubes
Plasmid DNA binding capacity (Physical adsorption)
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Document
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.