Exceptional value for money Rapid detection of all clinically relevant subtypes Positive copy number standard curve for quantification Highly specific detection profile High priming efficiency Broad dynamic detection range (>6 logs) Sensitive to < 100 copies of target
Accurate controls to confirm findings
150 reactions
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
Herpes Simplex Virus 1 (HSV-1) is a member of the herpes virus family, Herpesviridae. HSV-1 has a relatively large double-stranded DNA genome. HSVs are primarily transmitted by sexual intercourse, direct contact with lesions or perinatally. Most HSV positive cases are characterised by lesions on the skins and mucous membranes of the mouth and genitals. HSV infection can be either primary or a recurrence of a previous infection. More than 90% of the primary HSV infections are asymptomatic. Primary infection with HSV-1 can lead to gingivostomatitis, eczema herpeticum, keratoconjunctivitis and encephalitis. The primary symptoms of a secondary infection are skin lesions in the nose, mouth and genital regions. The infection is contagious, mainly during an epidemic.
HSV-1 TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
HSV-1 TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
The HiPure Total RNA Kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA (not include miRNA) from animal tissues, cells and simple plant tissues using one column
Applications
RT-PCR, qRT-PCR, Northern hybridization, second generation sequencing
Cells: ≤1 x 107 Animal tissue: 1-20 mgPlant leaves: 50-150 mg Yeast cells: 5 x 106
Yield
2-100μg
Elution volume
≥50μl
Time per run
≤15 minutes(1-24 samples)
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
HiPure RNA technology simplifies total RNA isolation. Samples are first lysed and then homogenized. Ethanol is added to the lysate to provide ideal binding conditions. The lysate is then loaded onto the HiPure silica membrane and RNA binds to the silica membrane, and all contaminants are efficiently washed away. For certain RNA applications that are sensitive to very small amounts of DNA, the residual amounts of DNA remaining can be removed using a convenient on-column DNase treatment. Pure, concentrated RNA is eluted in water.
Advantages
Efficient removal of DNA – unique genomic DNA removal column without DNase treatment
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Fast – several samples can be extracted in 20 minutes by column method
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
Kit Contents
Contents
R401102
R401103
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
50
250
RTL Lysis Buffer
50 ml
200 ml
RNA Binding Buffer
15 ml
75 ml
Buffer RW1
50 ml
200 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
The HiPure Total RNA Kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Gluconate, D-Glucono-δ-lactone
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
0.8 to 50 µg of D-gluconic acid per assay
Limit of Detection:
0.792 mg/L
Reaction Time (min):
~ 6 min
Application examples:
Wine, meat, processed meat (e.g. additives), fruit juice, dairy products, pharmaceuticals, paper and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by ISO, DIN and GOST
The D-Gluconic Acid/D-Glucono-δ-lactone test kit is suitable for the specific measurement and analysis of D-gluconic acid/D-gluconolactone in foods and beverages.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.
All reagents stable for > 2 years after preparation
Very competitive price (cost per test)
Very rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The D-Gluconic Acid/D-Glucono-δ-lactone test kit is suitable for the specific measurement and analysis of D-gluconic acid/D-gluconolactone in foods and beverages.