Description
Specifications
Clone | IHC564 |
Source | Mouse Monoclonal |
Positive Control | Breast |
Dilution Range | 1:200 |
E-cadherin is an intercellular adhesion molecule present in epithelial cells. Anti-E-cadherin stains glandular epithelium, as well as lung, gastrointestinal and ovarian adenocarcinomas. A panel of antibodies against E-cadherin and p120 is also used to differentiate ductal (membranous staining) and lobular breast cancer (cytoplasmic staining). Anti-E-cadherin also stains some thyroid cancers.
Clone | IHC564 |
Source | Mouse Monoclonal |
Positive Control | Breast |
Dilution Range | 1:200 |
Attogene’s Cadmium Lateral Flow Kit can be used to detect Cadmium in water samples at 5 ppb in the field.
Format: 10 test cassettes
Run Time: 15-30 minutes
Cadmium contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Cadmium accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking cadmium-contaminated food and water include numerous negative health effects. Attogene’s Cadmium Lateral Flow test gives results conforming of 5ppb or greater. Using the supplied pipette, simply fill the vial with your water sample, place the water into the sample port and wait 15-30 minutes.
Format: 10 test cassettes
Run Time: 15-30 minutes
Detection: Cadmium in water samples at 5 ppb
These kits are designed for the rapid spin column removal of endotoxins from previously purified DNA. Norgen’s spin columns bind DNA while endotoxins, salts and other contaminants are washed away. These kits reduce endotoxins to 0.1 EU/μg DNA or less providing plasmid DNA that is immediately ready for transfections or other endotoxin-sensitive applications. Typical recovery of DNA is >90% of the starting sample.
Endotoxin Removal Kit (Mini)
This kit is designed for the rapid spin column removal of endotoxins from up to 25 µg of previously purified DNA. The convenient spin column procedure can be completed in approximately 20 minutes.
Endotoxin Removal Kit (Midi)
This kit is designed for the rapid spin column removal of endotoxins from up to 200 μg of previously purified DNA. The convenient spin column procedure can be completed in approximately 30 minutes.
Endotoxin Removal Kit (Maxi)
This kit is designed for the rapid spin column removal of endotoxins from up to 1 mg of previously purified DNA. The convenient spin column procedure can be completed in approximately 30 minutes.
About Endotoxins
Endotoxins (also called lipopolysaccharides), are cell-membrane components of Gram-negative bacteria such as E. coli. Endotoxins are released during the lysis step of plasmid purification and significantly reduce transfection efficiencies in endotoxin sensitive cell lines. Therefore, the removal of endotoxins from plasmid preparations is often necessary prior to the use of the DNA in such downstream applications.
Figure 1 / 2
Click for expanded view
Kit Specifications | |
Maximum DNA Input | 25 μg |
Final Endotoxin Level | ≤ 0.1 EU/µg DNA |
Size of DNA Purified | Up to 13,000 bp |
Maximum DNA Volume Input | 100 μL |
Average Recovery | > 90% |
Time to Complete 10 Purifications | 20 minutes |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Component | Cat. 22700 (25 preps) | Cat. 52200 (10 preps) | Cat. 21900 (4 preps) |
---|---|---|---|
Buffer SK | 15 mL | 60 mL | 60 mL |
Wash Solution H | 18 mL | 18 mL | 18 mL |
Elution Buffer I | 6 mL | 12 mL | 12 mL |
Endotoxin Removal Solution | 1.5 mL | 1.5 mL | 1.5 mL |
Precipitation Solution | – | 1.5 mL | 1.5 mL |
Spin Columns (assembled with Collection Tubes) | – | 10 | 4 |
Spin Columns | 25 | – | – |
Collection Tubes | 25 | – | – |
Elution Tubes (1.7 mL) | 25 | – | – |
Elution Tubes (15 mL) | – | 10 | – |
Elution Tubes (50 mL) | – | – | 4 |
Product Insert | 1 | 1 | 1 |
DBCO-PEG5-DBCO is a bifunctional click chemistry reagent. DBCO will react with azide-bearing compounds or biomolecules to form a stable triazole linkage without copper catalyst. The hydrophilic PEG spacer arm can increase water solubility and membrane permability. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
DBCO-PEG5-DBCO is a bifunctional click chemistry reagent. DBCO will react with azide-bearing compounds or biomolecules to form a stable triazole linkage without copper catalyst. The hydrophilic PEG spacer arm can increase water solubility and membrane permability. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio