Discover our Yeast Extract Peptone Dextrose (YPD) Agar, designed for the cultivation and growth of yeasts and fungi, including Saccharomyces cerevisiae. This nutrient-rich medium supports robust mi……
Detail
Introduction
Discover our Yeast Extract Peptone Dextrose (YPD) Agar, designed for the cultivation and growth of yeasts and fungi, including Saccharomyces cerevisiae. This nutrient-rich medium supports robust microbial proliferation, making it ideal for molecular biology, fermentation, and genetic research.
>The display can simultaneously display:all main parameters such as cold trap temperature,vacuum degree,sample temperature, and shelf temperature.
>Schematic diagram of equipment operating components,through graphic display to view the working status of each component of the equipment.
>Ithas the functions of cold trap precooling and vacuum pump preheating,and the time can be set by the userin the system. >Display whether the current running status is normal or not by numerical color.
o One-key operation,the operation is extremely simple,no special professional learning and training is required.
o Thermal electromagnetic over-current and short-circuit protection,making the equipment run more safely and stably.
o Active reminder of equipment maintenance time and vacuum pump replacement lubricating oil time.
o Ambient temperature monitoring,the device automatically reminds the alarm if the ambient temperature is too high.
o Optional eutectic point detection device and endpointjudgment detection system make freeze-drying more scientific.
Dryingchamber
· The separate drying chamber reduces the probability of damage caused byimproper handling of the drying chamber due to height and weight.The upper cover is anodized aluminum with anti-corrosion treatment.●Highly transparent plexiglass drying chamber,good light and heat radiation conduction.Reserve 6/12 external valve ports.· 316L stainless steel all black Teflon coating drying chamber,suitable for drying organic solvents and various corrosive samples,reserved for 6/12 external ports.· 316L stainless steel vertical multi-port multi-manifold external rack(The standard configuration is aplexiglass drying chamber,and one ofthe diying chambers can be optional)
Coldtrapandcondensingcoil
· The cold trap cavity and condensation coil are made of 316L stainless steel.Large opening and channel design,the gas can be quickly captured through the condensing coil.· The cavity and condensing coil are equipped with Teflon anti corrosion coating as standard,which can trap organic solvents and various corrosive solvents.· The condensing coil is placed in the cold trap to increase the condensate catchment area,which can effectively prevent external condensation.
Sampleshelves
· 316Lstainless steel stackable sample shelves,capable oflyophilizing machine solvents and various corrosive solvents.Each shelf can be placed and taken freely without manual work.The distance and height ofeach shelfcan be adjusted freely.-All black coating,good heat absorption performance.-Special hole for freeze-drying of centrifuge tubes,which is conducive to the drying of samples in centrifugetube containers.· All-aluminum Teflon surface anti-corrosion treatment electric heating shelf.
Refrigerationsystem
· Danffos compressorCopper plate heat exchanger,the largest area to increase heat dissipation· Unique refrigeration technology,the temperature of the cold trap can be lowered from ambient temperatureto below-80C°within 2 minutes.· Class A temperature sensor with high temperature accuracy and low error.· Multiple detection and alarm system,the refrigeration system pressure is too high or refrigeration failure cantimely alarm and take corresponding measures.
Techinical parameter
ItemNo
ST7003
ST7006
ST9006
Ice condenser capacity
3kg
6kg
6kg
Ice condenser temperature
-70℃
-70℃
-90℃
Cold trap volume
5L
10L
10L
Freeze dried chamber
Bell shape (standard configuration)/Multi manifold type/T-shaped frame type
Sample shelf
φ200mm.Single layer area 0.03m2 with 3-5 layers available
●260mm/485mm.Single layer area 0.055m²/0.185m².3-10 layers/optional ● Electric heating/manual capping/optiona
Vacuum pump
Extreme vacuum 5*10*mbar with a pumping capacity of 8m³/h optional pump of various types
Oil mist filte
Standard configuration
Vacuum pump connection pipe
Single forming stainless steel flexible pipe DN16 ISO-KF L-1.2m
Anti-corrosive treatment
Cold trap,condensing coil/all equipped with PTFE anti-corrosion treatment as standard. Freeze-drying organic solvents.
External valve
6pieces/optional
1-48 pieces/optional
Eutectic point detection system
Support/Optional
Data output analysis
Support/Optional
Powe
0.6kw
1.1kw
1.5kw
Size
420*545*455mm
510*570*500mm
Document
Freezer Dryer, 3kgs-6kgs water capturer Model: ST7003,ST7006,ST9006
This product is designed for purification of high-molecular-weight genomic or mitochondrial DNA from a variety of blood samples. High-quality DNA can be purified from sample types including whole blood, buffy coat, bone marrow, body fluids in as little as 25 minutes. The convenient, scalable purification procedure removes contaminants and enzyme inhibitors such as proteins and divalent cation, and purified DNA is ready for immediate use in sensitive downstream applications or for archiving.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from whole blood using economic salt out method
Cells are lysed with ananionic detergent in the presence of a DNA stabilizer. The DNA stabilizer limits the activity of intracellular DNases and also DNases found elsewhere in the environment. RNA is then removed by treatment with an RNA digesting enzyme. Other contaminants, such as proteins, are removed by salt precipitation. Finally, the genomic DNA is recovered by precipitation with alcohol and dissolved in Buffer TE. Purified DNA typically has an A260/A280 ratio between 1.7 and 1.9, and is up to 200 kb in size. The DNA can be safely stored at 2-8°C, -20°C, or -80°C.
Advantages
Safe – without phenol chloroform extraction
Environment friendly – the reagents used are safe, non-toxic and without pollution
High molecular weight – the molecular weight of genomic DNA is about 50-150kb
High purity – the purified DNA has A260/280=1.8-1.9, A260/230=2.0-2.5
Unlimited sample size – solution type operation, sample volume can be adjusted at will
Cost performance – the most economical nucleic acid extraction technology
Kit Contents
Contents
D331101
D331102
D331103
Purification Volumes
50 ml
300 ml
1000 ml
10 x Buffer RBC
20 ml
100 ml
3 x 100 ml
Buffer WTL
60 ml
350 ml
1000 ml
Buffer PPS
20 ml
120 ml
350 ml
RNase Solution
300 µl
1.8 ml
6 ml
Buffer TE
10 ml
30 ml
120 ml
Storage and Stability
RNase Solution should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Document
This product is designed for purification of high-molecular-weight genomic or mitochondrial DNA from a variety of blood samples. High-quality DNA can be purified from sample types including whole blood, buffy coat, bone marrow, body fluids in as little as 25 minutes. The convenient, scalable purification procedure removes contaminants and enzyme inhibitors such as proteins and divalent cation, and purified DNA is ready for immediate use in sensitive downstream applications or for archiving.
NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms)
Product Info
Document
Product Info
The NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality NGS libraries with low input DNA amount from 1 ng to 400 ng. The kit allows scientist to study samples with limited DNA such as tumor samples, patient samples, and other specially collected samples (FACS sorting etc.). The kit has high library conversion efficiency with as little as 1 ng DNA input. The fast and simple 1.5-hour protocol makes libraries with even coverage and low GC-bias based our unique chemistry for DNA end-polishing and ligation.
The kit needs double strand DNA fragments (blunt and/or sticky) as input DNA for NGS library preparation, and is compatible with DNA fragments generated from both enzymatic approach (for example, BioDynami DNA fragmentation enzymes, Cat.# 40061 and Cat.# 40062) and mechanical approaches such as sonication and nebulization etc.
NGS Low Input DNA Library Prep Kit Workflow
Three index types are available for the NGS Low Input DNA Library Prep Kit of illumina platform:
Non-index (Cat.# 30022): Libraries do not have index.
Index (Cat.# 30024): Each of our index primers contains a unique barcode sequence with 6 bases that can be used to identify the low input DNA libraries. Library multiplexing up to 48 samples is possible. Index information can be downloaded here.
Unique dual index (Cat.# 30025): Library multiplexing up to 96 low input DNA libraries is possible with unique dual indexes with our Four-Base Difference Index System. The system allows us to make indexes for the libraries that have at least 4 bases different from each other in the 8-base barcode length. Our unique dual index primers can reduce sequencing errors such as de-multiplexing errors, amplification errors, mis-assignment of reads, index cross-contamination, and also index hopping. The kit includes 96 pre-mixed unique pairs of index primers. Index information can be downloaded here.
Indexes are available for the MGI platform kits (Cat.# 34024).
Kit advantages:
Fast protocol
The hands-on time is only 10 minutes
The total protocol time is around 1.5 hours
Simple procedure
Ready-to-use master mix makes it simple for reaction setup
Less reaction components
Less magnetic beads required for cleanup steps: Save the cost more than 50%
Low input DNA amount: Starts from 1 ng of DNA
Comparison of library conversion efficiency under the same NGS library preparation condition. Input DNA amounts are 1 ng and 10 ng, respectively. DNA was mechanical sheared with Covaris before library prep. BioDynami kit: NGS Low Input DNA Library Prep Kit (Cat. #30022).
Comparison of library yield under the same NGS library prep condition. Input DNA amounts are 1 ng, 10 ng, and 100 ng. DNA was mechanical sheared with Covaris before library prep. BioDynami kit (Cat. #30022). PCR cycle numbers were indicated.