Introduction
029080 Glycerin
Usage:Additive Reagent for Culture Media.
Specification:1ml*10vials
1ml*10vials

029080 Glycerin
Usage:Additive Reagent for Culture Media.
Specification:1ml*10vials
Norgen’s AAV Quantification Kit is designed for the detection of adeno-associated virus (AAV) inverted terminal repeat (ITR) sequences in a real-time PCR based on the use of TaqMan® technology. A purified standard based solely on the AAV2 ITR sequence purified using Norgen’s proprietary silicon carbide technology simplifies the generation of a reliable standard curve for AAV quantification. Avoidance of a plasmid based standard eliminates problems associated with efficient melting of the ITR sequence due to coupling of the ITR to the much longer plasmid sequence, as well as variability due to rearrangements/duplications/deletions of the recombination prone ITR. An easy and rapid method for viral DNA extraction simplifies the step of obtaining AAV DNA while simultaneously eliminating contaminating non-encapsidated DNA. Norgen’s AAV Quantification Kit can facilitate pre-clinical studies that require accurate vector titration as well as interlab comparisons of vector quantities. This kit is designed for research use only and not for use in diagnostic procedures.
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots. All reagents can be stored for 1 year at -20°C without showing any reduction in performance.
| Component | Cat. 63800 (24 rxns) |
|---|---|
| Enzyme Incubation Buffer A | 500 µL |
| DNase I | 25 µL |
| DNase Stop Solution | 100 µL |
| 2X PCR Mastermix | 350 µL |
| AAV Primer & Probe Mix | 90 µL |
| AAV Standard | 6 µL |
| Nuclease-Free Water (Negative Control) | 1.25 mL |
| Product Insert | 1 |
Sample type purification kit guide
The 16S V1-V2 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V1-V2 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.
The 16S V1-V2 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V1-V2 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.
Figure 1 / 3
Click for expanded view
| Minimum amount of starting material: | 2.5 µL of DNA (5 ng/µL) |
| Time to complete library preparation: | 4 hours |
Storage Conditions and Product Stability
Norgen’s 16S V1-V2 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components should remain stable for at least 1 year when stored at the specified storage conditions.
| Step | Component | Cat. 70100 (24 preps) | Cat. 70110, 70120, 70130, 70140 (96 preps) |
|---|---|---|---|
| Amplicon PCR (PCR 1) | MGX Master Mix | 330 µL | 1,320 µL |
| 16S V1-V2 Primer Mix | 70 µL | 280 µL | |
| Index PCR (PCR 2) | Indexing Master Mix | 660 µL | 2 x 1,320 µL |
| N7xx Index Primer | 50 µL | 50 µL | |
| S5xx Index Primer | 70 µL | 70 µL | |
| PCR Clean-Up | Resuspension Buffer | 2 x 1,250 µL | 2 x 5,000 µL |
| Nuclease-free water | 1,250 µL | 1 x 6,000 µL |
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected*. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings