CP0203J Triple Wrapped Irradiated Plate-Tryptic Soy Agar with Lecithin Tween 80
Facebook
X
Pinterest
Email
55mm*10 plates / bag
Detail
Introduction
Usages:
For monitoring and detection of surface of equipment and personnel hygiene which have disinfectant or antibiotics.
Advantage: 1.This series of products was filling at A level of environment, and final sterilization by Gamma ray irradiation, triple packaging insure sterility and long shelf life. 2.Each dish was marking label product name, batch number, expiration date .Information is available of traceability. 3.Inner additional desiccant, reducing formation of condensation water, while inner additional sterile paper and plastic bags for easier transfer and cultivation. 4.Triple packing dense bags to avoid the penetration of hydrogen peroxide; clean gas was filled as a buffer to reduce broken bags and dish in transit.. 5.This series of products is available to store at (2-25 ℃), shelf life of up to 6 months.
Storage: Store in a cool (2-25 ℃), dry place, away from bright light. Storage period of 6 months.
Specifications: 55mm*10 plates / bag
Other Products
NEST 96-Well Plate, Flat (100 count)
Product Info
Document
Product Info
NEST 96 Well Plate Flat, polystyrene, sterile, DNase, RNase, pyrogen, and endotoxin free. Individually wrapped.
100 count, 200 uL max volume per well
Labware definition is available for immediate use in Opentron’s Labware Library
Document
NEST 96 Well Plate Flat, polystyrene, sterile, DNase, RNase, pyrogen, and endotoxin free. Individually wrapped.
100 count, 200 uL max volume per well
Labware definition is available for immediate use in Opentron’s Labware Library
The Flex caddy allows the Thermocycler GEN2 to be installed on the Opentrons Flex deck and sit below the deck, enabling below-deck cable routing and labware placed on top of modules to remain closer to the deck surface. The calibration adapter is used to calibrate the location of the Thermocycler. Caddies and calibration adapters are specific to the type of module.
Note: This item does not include the Thermocycler Module. The module is available with or without the Flex Caddy and Calibration tool: Thermocycler Module GEN2
Document
The Flex caddy allows the Thermocycler GEN2 to be installed on the Opentrons Flex deck and sit below the deck, enabling below-deck cable routing and labware placed on top of modules to remain closer to the deck surface. The calibration adapter is used to calibrate the location of the Thermocycler. Caddies and calibration adapters are specific to the type of module.
Note: This item does not include the Thermocycler Module. The module is available with or without the Flex Caddy and Calibration tool: Thermocycler Module GEN2
CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
Bacillus cereus is a rod-shaped, gram-positive bacterium. Some strains of B. cereus cause foodpoisoning and other diseases such as keratitis. B. cereus grows at a wide range of temperature, from 4°C to 37°C. In fact, many foodborne illnesses caused by B. cereus are a consequence of improperly cooked or improperly stored food, including dairy products and meats. The majority of food poisoning by B. cereus could be divided into two types of symptoms – the emetic type and the diarrheal type, both of which are caused by the enterotoxin produced by the bacteria.
Bacillus cereus TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
Bacillus cereus TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.