How to use: 1.Suspend 38g in 1 L of distilled water , stirring heated to boiling until completely dissolved, dispensing flask, 121 ℃ autoclave for 15min. 2.Diluted and treated samples.
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light. Storage period of 3 years.
Specifications: 250g/bottle
Other Products
D2122 HiPure Clean Up 96 Kit
Product Info
Document
Product Info
Introduction
HiPure DNA Clean Up 96 Kit uses proprietary chemistry and HiPure technology to recover DNA Fragments between 60bp-10kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Details
Specifications
Features
Specifications
Main Functions
Recover DNA fragments between 60bp-10kbp from PCR, Reactions, crude DNA using 96 well Bind Plate
Applications
PCR, sequencing, labeling reactions, ligations and restriction digestion, etc.
Purification method
96 well Bind Plate
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
PCR product, enzymatic reaction
Sample amount
Appropriate
Recovery
≥80%
Elution volume
≥75μl
Time per run
≤60 minutes
Liquid carrying volume per column
800µl
Binding yield of column
20µg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
High recovery efficiency – ≥80% DNA recovery
Fast – isolation can be completed in 60 minutes
Kit Contents
Contents
D212201
D212202
D212203
Purification Times
1 x 96 Preps
4 x 96 Preps
20 x 96 Preps
Buffer GDP
120 ml
400 ml
4 x 400 ml
Buffer DW2
20 ml
100 ml
3 x 100 ml
Elution Buffer
20 ml
20 ml
30 ml
HiPure DNA Plate
1
4
20
2.2ml Collection Plate
1
4
20
1.6 ml Collection Plate
1
4
20
0.8 ml Collection Plate
1
4
20
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve.
Document
HiPure DNA Clean Up 96 Kit uses proprietary chemistry and HiPure technology to recover DNA Fragments between 60bp-10kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
RNA Basic Isothermal PCR Kit With High Accuracy And Efficiency
Product Info
Document
Product Info
Product Description
Product Detail
Kit Storage and term of Validity
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature:at room temperature and constant temperature(generally 39℃~42℃),reverse transcriptaseuses specific primers and template RNA tosynthesize cDNA strands,and binds the auxiliary protein and single strand with the help of the protein, the recombinase and the primer form a complex; perform a homology search and bind the target homology domain, at this time a D-loop region is formed at the homology positionand strand exchange begins; accompanied by the recombinase from the complex upon dissociation,the polymerase also bindsto the 3′ end of the primer,initiating chainextension.It is suitable for laboratory-level RNA amplification and RNA amplification for other detection purposes.
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
3/ The reaction can be operated by metal bath and water bath pot without purchasing expensive PCR apparatus.
Technical Parameters:
Parameters
Details
Product Name
RNA Isothermal Amplification Kit Basic
Manufacturer
Amp-future
Storage Temperature
-20°C
Kit Components
Enzymes, Buffers ,Reagents
Packaging
48 Tests/box
Detection Limit
500-1000copies/µL
Shipping
ICE
Test Time
5-20mins
Isothermal nucleic acid Applications
Suitable for RNA isothermal rapid amplification kit(Basic type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
RNA basic kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.
Document
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.