
500g

These kits are suitable for the isolation of total RNA from a range of samples including cells, bacteria, yeast, virus and bodily fluids including plasma/serum, blood, saliva, CSF and more. Extract high quality and purity RNA with excellent RIN values and A260/A280 suitable for downstream applications including qRT-PCR, RT-PCR, microarrays, NGS and more. These kits purify all sizes of RNA from large mRNA, lncRNA down to microRNA (miRNA) in the same fraction without the requirement of phenol. Isolate all RNA sequences at an equal rate irrespective of size. Moreover, when the RNA sequences are small (e.g. miRNA), the column binds small RNAs regardless of their GC content.
Total RNA Purification 96-Well Kit (High Throughput and High Throughput Deep Well)
This 96-well kit provides a rapid method for the high-throughput isolation and purification of total RNA in 30 minutes using vacuum manifold, plate centrifuge, or liquid handlers with vacuum capabilities. Total RNA can be isolated from a broad range of sample sources including cultured cells, tissues, blood, serum, plasma, bacteria, yeast, fungi, and viruses.
Isolate RNA after Purifying EVs and Exosomes
Ultracentrifugation, Exoquick, Filtration
| Cat. # | Name | Elution Volume | Plasma/Serum | Urine | Cell-Culture Media |
|---|---|---|---|---|---|
| 55000 | Plasma/Serum RNA Purification Mini Kit | 10 – 25 µL | 50 µL – 1 mL | 250 µL – 1 mL | 5 – 10 mL |
| 35300 | Total RNA Purification Micro Kit | 20 – 50 µL | 1 – 4 mL | 2 – 10 mL | 10 – 20 mL |
| 17200 | Total RNA Purification Kit | 50 – 100 µL | 4 – 10 mL | 11 – 30 mL | 20 – 35 mL |
Figure 1 / 13
Click for expanded view
| Kit Specifications | |
| Maximum Binding Capacity Per Well | 50 μg |
| Maximum Loading Volume Per Well | 500 μL |
| Size of RNA Purified | All sizes, including small RNA (< 200 nt) |
| Maximum Amount of Starting Material: | |
| Animal Cells | 1 x 106 cells |
| Animal Tissues | 10 mg |
| Blood | 100 μL |
| Plasma/Serum | 150 μL |
| Bacteria | 1 x 109 cells |
| Yeast | 1 x 108 cells |
| Fungi | 40 mg |
| Plant Tissues | 40 mg |
| Time to Complete 96 Purifications | 30 minutes |
| Average Yields* | |
| HeLa Cells (1 x 106 cells) | 15 μg |
| E. coli (1 x 109 cells) | 50 μg |
* average yields will vary depending upon a number of factors including species, growth conditions used and developmental stage.
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
| Component | Cat. 17200 (50 preps) | Cat. 37500 (100 preps) | Cat. 17250 (250 preps) | Cat. 17270 (500 preps) | Cat. 24300 (192 preps) | Cat. 24370 (576 preps) | Cat. 24350 (192 preps) | Cat. 24380 (576 preps) |
|---|---|---|---|---|---|---|---|---|
| Buffer RL | 40 mL | 2 x 40 mL | 175 mL | 350 mL | 2 x 40 mL | 350 mL | 2 x 40 mL | 350 mL |
| Wash Solution A | 38 mL | 2 x 38 mL | 148 mL | 1 x 148 mL 1 x 74 mL | 2 x 38 mL | 1 x 74 mL 1 x 148 mL | 2 x 38 mL | 1 x 74 mL 1 x 148 mL |
| Elution Solution A | 6 mL | 2 x 6 mL | 30 mL | 60 mL | 2 x 20 mL | 60 mL | 2 x 20 mL | 60 mL |
| Mini Spin Columns | 50 | 100 | 250 | 500 | – | – | – | – |
| 96-Well Isolation Plate | – | – | – | – | 2 | 6 | – | – |
| 96-Well Isolation Plate (Deep Well) | – | – | – | – | – | – | 2 | 6 |
| Adhesive Tape | – | – | – | – | 4 | 12 | 4 | 12 |
| Collection Tubes | 50 | 100 | 250 | 500 | – | – | ||
| 96-Well Collection Plate | – | – | – | – | 2 | 6 | – | – |
| 96-Well Collection Plate (Deep Well) | – | – | – | – | – | – | 2 | 6 |
| Elution Tubes (1.7 mL) | 50 | 100 | 250 | 500 | – | – | ||
| 96-Well Elution Plate | – | – | – | – | 2 | 6 | – | – |
| 96-Well Elution Plate (Deep Well) | – | – | – | – | – | – | 2 | 6 |
| Product Insert | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Specifications
| Features | Specifications |
| Recommended application | Small amounts of nucleic acid isolation, viral nucleic acid from cell free samples |
| Preservation conditions | Room temperature |
| Stability | Up to 4 years |
| Filter membrane | High quality glass fiber filter GF/F, 2 layers |
| Membrane aperture | 0.7μm |
| Maximum binding yield of plasmid | 30 μg |
| Maximum yield of alcohol mediated Binding | 100 μg |
| Single liquid carrying capacity of column | 900 μl |
| Minimum elution volume | 80 μl |
| Withstand centrifugal force | 5,000 x g |
| Centrifuge | Low speed centrifuge, Swing out Rotor, can placed a height of 6.5cm square, (height of HiPure DNA Plate & 1.6ml Collection Plate: height, 6.2cm) |
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
| CAT.No. | Product Name | Package |
| C13130 | HiPure DNA Plate (2 x GF/F)with 1.6ml Collection Plate | 10/Bag |
| Item No. | Product Name | Membrane type/number of layers | Collection tubes | Plasmid DNA binding capacity (Physical adsorption) | gDNA/RNA binding capacity (Alcohol-mediated adsorption) | Minimum Elution volume | Liquid volume capacity |
| C13010 | HiPure DNA Nano Column | 2 layers GF/F | 2ml without cap | 5μg | 20μg | 10μl | 700μl |
| C13011 | HiPure DNA Micro Column | 3 layers GF/F | 2ml without cap | 10μg | 50μg | 15μl | 700μl |
| C13100 | HiPure DNA Mini Column I | 2 layers GF/B | 2ml without cap | 15μg | 100μg | 30μl | 700μl |
| C13110 | HiPure DNA Mini Column II | 4 layers GF/B | 2ml without cap | 35μg | 200μg | 50μl | 800μl |
| C13111 | HiPure RNA Mini Column | 3 layers GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
| C13112 | HiPure Viral Mini Column | 3 layers GF/F | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
| C13113 | HiPure CFDNA Mini Column | 3 layers GF/F,1 layer GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
| C13120 | HiPure DNA Midi Column | 4 layers GF/B | 15ml Centrifuge tube | 125μg | 1mg | 500μl | 4ml |
| C13121 | HiPure DNA Midi Column III | 8 layers GF/B | 15ml Centrifuge tube | 250μg | 1mg | 500μl | 4ml |
| C13122 | HiPure DNA Maxi Column | 4 layers GF/B | 50ml Centrifuge tube | 500μg | 5mg | 1000μl | 20ml |
| C13123 | HiPure DNA Maxi Column III | 8 layers GF/B | 50ml Centrifuge tube | 1mg | 5mg | 1000μl | 20ml |
| C13124 | HiPure DNA Maxi Column C | 8 layers GF/B | 50ml high speed Centrifuge tube | 1mg | 5mg | 700μl | 12ml |
| C13130 | HiPure DNA Plate | 2 layers GF/F | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
| C13131 | HiPure gDNA Plate | 2 layers GF/B | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.