Attogene has developed the first of its kind and patent pending technology that uses a novel RNA substrate tagged on the 5′ and 3′ end with a Biotin that is attached to our streptavidin colloidal gold reporter molecules and a test line tag. In the absence of RNases, the gold tagged RNA molecule will flow up the lateral flow strip and bind to the test line using an anti tag antibody (INDICATING that NO RNase is detected). When RNases are present, however, the RNA substrate is cleaved, and the 5′ and 3′ tags are spatially separated in solution cauing the test line to disapear.
This test can be used to rapidly and efficiently detect ribonucleases in both liquid and on solid surfaces and a perfect tool for monitoring mRNA vaccine manufacturing.
RNase activity in a convenient and sensitive colormetric assay that delivers results in real time. Great for Quality Testing for RNase contamination of materials and supplies.
TGM12 Table top capillary vessel Haematocrit centrifuge
Application:
Measure the ratio of blood corpuscle and separate microblood and micro solution.
Model: TGM12 Table top high speed capillary vessel centrifuge
Features:
Brushless DC motor, free maintenance, no powder pollution, micro computer control, digital display indicates the time、speed and RCF. Electric lid lock、 over speed and imbalance protection. The centrifuge body is made of high quality steel, Safe and reliable.
Technical parameters:
Max speed | 12000r/min | Max RCF | 15800×g |
Time range | 1~99min | Speed accuracy | ±20r/min |
capacity | 24pieces capillary vessel | Noise | ≦55dBA |
Weight | 13KG | Dimension | 355×270×205mm |
Packaged weight | 15KG | Packaged dimension | 455×335×270mm |
Power | AC 220V 50HZ 5A | Motor | Brushless |
Package | Carton box |
These kits provide a fast, reliable and convenient method to sequentially isolate and concentrate exosomal RNA as well as Free-Circulating RNA from different plasma/serum sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA as well as all sizes of the free-circulating protein-bound RNA, including microRNA. These kits provide a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, these kits allow the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Mini Kit
For sample volumes ranging from 50 µL to 1 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Midi Kit
For sample volumes ranging from 1 mL to 4 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Maxi Kit
For sample volumes ranging from 4 mL to 10 mL.
Figure 1 / 6
Click for expanded view
Kit Specifications | |
Minimum Plasma Input | 4 mL |
Maximum Plasma Input | 10 mL |
Size of RNA Purified | All sizes, including miRNA and small RNA (< 200 nt) |
Elution Volume | 50 – 100 µL |
Time to Complete 10 Purifications | 40 – 45 minutes |
Average Yields* | Variable depending on specimen |
*Please check page 5 of the product insert for the average yields and the common RNA quantification methods
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note
This kit is suitable for the purification of exosomes from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.
Component | Cat. 59500 (50 preps) | Cat. 59600 (25 preps) | Cat. 59700 (15 preps) |
---|---|---|---|
Slurry E | 12.5 mL | 12.5 mL | 12.5 mL |
ExoC Buffer | 8 mL | 8 mL | 2 x 8 mL |
ExoR Buffer | 12 mL | 12 mL | 12 mL |
Lysis Buffer A | 2 x 20 mL | 2 x 20 mL | 2 x 20 mL |
Lysis Additive B | 2 mL | 2 mL | 2 mL |
Wash Solution A | 2 x 18 mL | 18 mL | 18 mL |
Elution Solution A | 2 x 6 mL | 6 mL | 6 mL |
Mini Filter Spin Columns | 50 | 25 | 15 |
Mini Spin Columns | 100 | 50 | 30 |
Collection Tubes | 100 | 50 | 30 |
Elution Tubes (1.7 mL) | 100 | 50 | 30 |